Abstract
Based on the well logging requirements of horizontal stripper wells, the flow characteristics of the oil-water two-phase flow in the invisible horizontal tri-electrode capacitive sensor (HTCS) measurement pipeline are studied. First, an experimental device and a numerical validation model of a horizontal 20 mm glass pipeline are established to study the flow characteristics of the oil-water two-phase flow. Then, the flow characteristics of the horizontal oil-water two-phase flow in the measurement pipeline under different horizontal inclination angles are studied and the flow patterns and inclination angles suitable for the new tri-electrode capacitive sensor are discussed. Finally, using the horizontal oil-water two-phase flow loop platform of the largest oil and gas testing center in China, the dynamic response of the new capacitive sensor is studied under different inclination angles, flow rates, and water-cut conditions, and the dynamic response law is analyzed based on the simulation results.
Introduction
In the oil industry, horizontal wells are essential for accessing difficult reservoirs, but they frequently encounter water immersion issues. Effective well management requires precise measurement of the water-cut (the ratio of water to oil). However, measuring this in horizontal pipelines is significantly more challenging than in vertical ones. In horizontal flow, fluids do not mix predictably; instead, they form complex patterns such as stratified layers, dispersed bubbles, or emulsions depending on flow velocity and pipe inclination. These varying flow patterns alter the electrical properties measured by sensors. Furthermore, the internal geometry of high-performance sensors often obscures the fluid behavior, creating an "invisible" measurement environment.
Methodology
The researchers addressed the challenge of internal flow visualization through a multi-faceted approach involving sensor design, numerical simulation, and experimental validation.
Sensor Design
A "combined" tri-electrode capacitive sensor was developed, featuring a center electrode rod, an intermediate metal layer electrode, and an outer shell. This configuration increases the contact area and resolution compared to traditional coaxial sensors.
Numerical Simulation and Validation
Computational Fluid Dynamics (CFD) using FLUENT software was employed to build a 2D axisymmetric model of the sensor’s internal annular pipeline. To ensure realism, the model included "slits" in the center electrode to mimic 3D fluid bypass behavior. Validation was performed using a transparent Plexiglas DN20 pipe and high-speed cameras to correlate observed flow patterns with simulation results.
Dynamic Loop Testing
The sensor prototype was tested at a major oil and gas testing center in Daqing, China. The experimental setup utilized a full-scale flow loop with D110 white oil and water, covering flow rates from 3 to 30 m³/d and water-cuts from 10% to 100%. Tests were conducted at inclination angles of 0°, +5°, and -5° to simulate typical horizontal well deviations.
Results and Discussion
The study revealed several critical insights into the sensor's performance and the physics of horizontal oil-water flow.
Sensor Response and Sensitivity
The sensor successfully measured water-cut across the entire 0% to 100% range. It demonstrated higher resolution at low-to-medium water-cuts. As the flow rate increased, the sensitivity improved, evidenced by a wider gap between response curves at higher flow rates.
The Shielding Effect and Inclination Sensitivity
A significant finding was the "shielding" effect at high water-cuts (above 90%). Due to water's high dielectric constant and conductivity, it can effectively blind the sensor to residual oil, causing the output to jump to a "full water" state prematurely.
Additionally, even minor inclination angles (±5°) significantly affected the "slip" between oil and water phases. At low flow rates, positive tilts biased the sensor toward oil, while negative tilts biased it toward water, highlighting the necessity for inclination-specific calibration.
Conclusion
The new tri-electrode capacitive sensor provides a robust solution for water-cut measurement in horizontal wells, with CFD models accurately predicting behavior in "invisible" pipelines. While the shielding effect at very high water-cuts remains a limitation, the sensor's performance in bubble-like flow regimes at high flow rates is excellent. Future work will focus on developing real-time inclination compensation algorithms and exploring materials to mitigate the shielding effect.
Summary updated