Abstract
In oil and gas gathering and transportation systems, factors such as flow pattern, inertia, and gravity often lead to uneven flow distribution across outlet pipes, impacting economic efficiency and safety. This study develops an experimental device to analyze gas-liquid two-phase flow maldistribution in horizontal pipelines under stratified, slug, and annular flow patterns. Results indicate that slug flow is most conducive to controlling liquid maldistribution in manifolds without flute pipes, while annular flow is optimal for gas distribution control. Surprisingly, the inclusion of internal "flute pipes" often exacerbated maldistribution. These findings provide a reference for field control of multi-phase flow in transportation systems.
Introduction
Efficiently splitting gas-liquid mixtures into multiple branches is a critical challenge in pipeline engineering. Ideally, a manifold should distribute phases proportionally to the branch outlets. However, the inherent differences in density and velocity between gas and liquid phases, coupled with gravitational and inertial forces, lead to "maldistribution." This phenomenon results in downstream processing inefficiencies and potential equipment damage. While hardware solutions like internal perforated "flute pipes" are commonly employed, their effectiveness across different horizontal flow regimes remains poorly understood.
Experimental Methodology
To investigate these dynamics, a specialized experimental rig was constructed. The setup featured a transparent 50mm diameter plexiglass manifold to allow for high-definition visual recording of flow patterns. A key component of the study was the "flute pipe"—a 20mm diameter internal distributor with multiple perforations.
The experiments utilized air and dyed water to simulate multi-phase flow. Liquid distribution was measured using electronic scales, while gas distribution was tracked via anemometers at the outlets. The researchers tested 18 distinct flow conditions, with gas flow rates ranging from 2.09 to 26.64 L/s and liquid flow rates from 0.10 to 0.65 L/s.
Results and Discussion
The study quantified the "maldistribution degree"—the percentage deviation from a perfect split. The data revealed several key insights:
The Flute Pipe Paradox
Contrary to conventional wisdom, adding a flute pipe often worsened distribution. In slug flow, liquid maldistribution jumped from 5.16% to 25.29% upon the addition of the flute pipe. This is attributed to the reduced cross-sectional area within the main pipe, which increases fluid velocity and induces higher turbulence and instability.
Impact of Flow Patterns
Flow regimes played a dominant role in distribution stability:
- Slug Flow: Proved most stable for liquid distribution when no flute pipe was present (average 5.16% maldistribution).
- Annular Flow: Offered the best gas distribution control without a flute pipe (average 3.02% maldistribution).
Non-Linear Distribution Trends
Maldistribution does not follow a linear path relative to gas-liquid ratios. Instead, it exhibits a "zigzag" pattern. For instance, in stratified flow, liquid maldistribution may remain stable before peaking sharply as flow conditions shift, reflecting the complex interplay of forces at the gas-liquid interface.
Conclusion
This research suggests that for horizontal manifolds, the most effective control strategy may be to avoid internal distributors like flute pipes and instead manage flow velocities to maintain favorable regimes (slug for liquid, annular for gas). While these results provide a strong foundation, future work should address the limitations of using air-water mixtures versus real-world hydrocarbons, as well as the effects of pipeline inclination and larger industrial scales.