SQUID G.A.M.E.: Gamma, Atmospheric, and Mono-Energetic Neutron Effects on Quantum Devices

Gioele Casagranda, Elizabeth C. Auden, Carlo Cazzaniga, Maria Kastriotou, Christopher Frost, Marzio Vallero, Flavio Vella, Paolo Rech

Abstract

Quantum devices are a promising solution to many research applications, including medical imaging, precision magnetic field measurements, condensed matter physics, and overcoming the limits of classical computing. Among the available implementations, the superconducting technology is the current focus of scientific research and industrial applications, excelling in performance and scalability. Despite this, superconducting quantum systems are extremely prone to decoherence, and in particular, they are highly sensitive to radiation events. In this paper, we analyze the response of a superconducting device (SQUID) to radiation. We expose the SQUID to beams of monoenergetic 14 MeV neutrons (NILE - ISIS), atmospheric 1-800 MeV neutrons (ChipIR - ISIS), and gamma rays with 1.25 MeV average energy (CALLIOPE - ENEA). These experiments show that the SQUID is sensitive to the two neutron fields, while gamma rays at 1.25 MeV leave it mostly unaffected. Following our experiments with neutrons, it is possible to characterize the SQUID's response and even classify faults according to their shape and duration. We identify two categories: bursts (long lasting) and peaks (short lived). To investigate the different responses to neutrons and gamma rays, we employ Geant4 simulations, which highlight differences in the deposition spectra and the energy propagation, but likewise predict the vulnerability of the SQUID in both cases.

Introduction

Superconducting quantum computers are scaling up rapidly, but they share a fundamental Achilles' heel: extreme sensitivity to environmental noise. Specifically, ionizing radiation from cosmic rays and trace radioactive materials can break "Cooper pairs"—the bound electrons that enable superconductivity—causing decoherence and transient faults. While it is known that radiation is a bottleneck, the exact microscopic relationship between specific impinging particles (like neutrons vs. gamma rays) and the resulting electrical faults remains poorly understood. This paper systematically characterizes these radiation-induced faults on a Superconducting QUantum Interference Device (SQUID), the foundational building block of superconducting qubits.

Experimental Methodology

The researchers tested a commercial high-temperature YBCO-based SQUID, cooled to 77 K using liquid nitrogen, across three different radiation facilities: NILE (14 MeV mono-energetic neutrons), ChipIR (1-800 MeV atmospheric-like neutrons), and CALLIOPE (1.25 MeV gamma rays from a Cobalt-60 source).

Experimental setup and microscopic views of the YBCO-based SQUID device used in the radiation tests.

To isolate the effects of radiation, the team developed a deterministic filtering technique to separate true radiation-induced faults from stochastic background noise. True radiation events perturbed both the current and voltage channels, whereas environmental noise typically only affected voltage in specific "sawtooth" or oscillating patterns. To supplement physical experiments, Geant4 and the G4CMP toolkit were used to simulate energy deposition and the subsequent propagation of phonons and charge pairs within the device's substrate.

Radiation-Induced Fault Characterization

Radiation events manifest as distinct electrical signatures rather than generic noise. The study categorized these into two types: Bursts (long-lasting perturbations around 100 $\mu s$) and Peaks (short-lived spikes around 100 ns). Both types exhibit similar voltage amplitudes ranging from 50 to 250 mV.

Time-domain output monitoring current and voltage channels to identify radiation-induced transients against trigger thresholds.

The type of radiation dictates the fault signature. Atmospheric neutrons (ChipIR) produced a high ratio of "peak" faults (~60% of total events), whereas 14 MeV mono-energetic neutrons (NILE) almost exclusively produced "bursts." The SQUID's sensitivity to neutrons was quantified with cross-sections of $\sigma_n \approx 2.0 \times 10^{-9} \text{ cm}^2$ for 14 MeV neutrons and $1.1 \times 10^{-9} \text{ cm}^2$ for atmospheric neutrons.

The Gamma Ray Anomaly and Simulation Insights

Simulations predicted that gamma rays should cause frequent faults; however, the live gamma experiment recorded zero transient events. Surprisingly, weeks later, the SQUID became hyper-sensitive to basic electromagnetic noise, rendering it virtually unusable. This implies that while gamma rays might not trigger immediate measurable transient Cooper-pair breaking in this setup, the accumulated dose causes severe, potentially permanent structural damage.

Geant4 simulations revealed that for equal fluence, neutrons deposit about 1.33x more energy into the substrate than gamma rays. Furthermore, in approximately 25% of neutron interactions, the energy released in the device is greater than the initial energy of the gamma rays tested.

Discussion and Future Work

The failure to detect transient gamma-ray faults was likely an artifact of the facility setup, where 30-meter coaxial cables attenuated ultra-fast, low-voltage signals. Additionally, testing at 77 K introduces significant thermal noise compared to the millikelvin temperatures of actual quantum computers. Future research should utilize signal amplifiers placed directly at the SQUID interface and 0 K-capable cryostats to drastically reduce thermal noise and improve signal fidelity during irradiation.

Summary updated

Abstract

Quantum devices are a promising solution to many research applications, including medical imaging, precision magnetic field measurements, condensed matter physics, and overcoming the limits of classical computing. Among the available implementations, the superconducting technology is the current focus of scientific research and industrial applications, excelling in performance and scalability. Despite this, superconducting quantum systems are extremely prone to decoherence, and in particular, they are highly sensitive to radiation events. In this paper, we analyze the response of a superconducting device (SQUID) to radiation. We expose the SQUID to beams of monoenergetic 14 MeV neutrons (NILE - ISIS), atmospheric 1-800 MeV neutrons (ChipIR - ISIS), and gamma rays with 1.25 MeV average energy (CALLIOPE - ENEA). These experiments show that the SQUID is sensitive to the two neutron fields, while gamma rays at 1.25 MeV leave it mostly unaffected. Following our experiments with neutrons, it is possible to characterize the SQUID's response and even classify faults according to their shape and duration. We identify two categories: bursts (long lasting) and peaks (short lived). To investigate the different responses to neutrons and gamma rays, we employ Geant4 simulations, which highlight differences in the deposition spectra and the energy propagation, but likewise predict the vulnerability of the SQUID in both cases.
BibTeX
@article{casagranda2026squid,
  author = {Gioele Casagranda and Elizabeth C. Auden and Carlo Cazzaniga and Maria Kastriotou and Christopher Frost and Marzio Vallero and Flavio Vella and Paolo Rech},
  title = {{SQUID G.A.M.E.: Gamma, Atmospheric, and Mono-Energetic Neutron Effects on Quantum Devices}},
  journal = {IEEE Transactions on Nuclear Science},
  year = {2026},
  doi = {10.1109/tns.2026.3657307},
}
Figure