Revisiting MAE pre-training for 3D medical image segmentation

Tassilo Wald, Constantin Ulrich, Stanislav Lukyanenko, Andrei Goncharov, Alberto Paderno, Leander Maerkisch, Paul F. Jäger, Klaus H. Maier-Hein · DOI

TL;DR

This paper revisits Masked Autoencoders (MAEs) for 3D medical image segmentation, a field where self-supervised learning (SSL) has lagged behind NLP and 2D vision. By addressing key limitations like small datasets, outdated architectures, and poor evaluation practices, they achieve state-of-the-art performance, outperforming even a strong, dynamically configured nnU-Net baseline by ~3 Dice points.

What Problem Does This Paper Address?

Self-supervised learning (SSL) has revolutionized many AI domains by enabling models to learn from vast amounts of unlabeled data. However, its adoption in 3D medical image segmentation has been hampered by several critical issues:

  1. Limited Pre-training Data: Many SSL methods for medical imaging rely on relatively small datasets, hindering their ability to learn robust, generalizable representations.
  2. Outdated Architectures: Existing SSL approaches often use older or transformer-based architectures, which may not be optimal for 3D medical image analysis compared to well-established Convolutional Neural Networks (CNNs) like U-Nets.
  3. Insufficient Evaluation: A lack of rigorous and standardized evaluation practices makes it difficult to compare methods fairly, leading to unclear conclusions about their true efficacy.

These pitfalls have prevented SSL from reaching its full potential in unlocking the value of abundant, yet unlabeled, clinical data.

Methods

The authors tackle these challenges by developing a robust MAE pre-training framework for 3D CNNs, specifically using a Residual Encoder U-Net architecture within the nnU-Net framework. Their approach involves:

  • Large-Scale Pre-training Dataset: They leverage a proprietary dataset of 39,168 3D brain MRI volumes, significantly larger than datasets used in many prior SSL studies.
  • State-of-the-Art Architecture: They employ a Residual Encoder U-Net, a proven architecture for 3D medical segmentation, ensuring their SSL method benefits from a strong foundation.
  • Optimized MAE for CNNs: They adapt the MAE concept to CNNs by introducing specific techniques like sparse convolutions, mask tokens, and densification convolutions to handle masked regions effectively.
  • Rigorous Development Framework: A systematic approach involving 5 development and 8 testing datasets allowed for performance-driven design decisions and disentangled the impact of pre-training from architectural choices.
  • Fine-tuning Strategies: They explore various fine-tuning strategies, including weight transfer (encoder/decoder), learning rate schedules, and warm-up phases, to optimize performance.

Datasets

The paper utilizes a comprehensive set of datasets for both development and evaluation:

  • Pre-training Dataset: A proprietary dataset of 39,168 3D brain MRI volumes from 44 centers, including T1, T2, T1 FLAIR, and T2 FLAIR modalities.
  • Development Datasets (5): MS FLAIR (D1), Brain Mets (D2), Hippocampus (D3), Atlas22 (D4), and CrossModa (D5) were used for iterative design and hyperparameter tuning.
  • Testing Datasets (8): Cosmos (D6), ISLES22 (D7), HaNSeg (D8), HNTS-MRG24 (D9), BraTS Africa (D10), T2 Aneurysms (D11), TOF Angiography Aneurysms (D12), and BraTS Mets (D13) were used for final evaluation.

Key Insights and Ideas

  • MAE's True Potential in 3D Medical: The study demonstrates that MAEs, when properly configured for 3D CNNs and trained on sufficient data, can achieve performance levels previously unseen in SSL for this domain.
  • Architecture Matters: Using a strong, established CNN backbone (ResEnc U-Net) is crucial for SSL success in 3D medical imaging, outperforming older architectures or transformer-based methods in many cases.
  • Evaluation is Key: The paper highlights the importance of diverse and rigorous evaluation across multiple datasets to truly assess the generalization capabilities and effectiveness of SSL methods.
  • Dynamic vs. Fixed Configurations: While dynamic configurations (adapting to each dataset) can be beneficial for from-scratch training, pre-training can often bridge the performance gap, sometimes even surpassing dynamic setups.
  • Fine-tuning is Critical: The choice of fine-tuning strategy (e.g., learning rate, warm-up, weight transfer) significantly impacts the final performance, and a full fine-tuning schedule is generally superior to shorter ones.

Key Results

  • State-of-the-Art Performance: The proposed MAE pre-trained model (Spark3D) achieved an average of approximately +3 Dice points improvement over the strong nnU-Net baseline across 11 test datasets.
  • Outperforming Baselines: Spark3D consistently outperformed other SSL methods (VoCo, VF, MG) and from-scratch baselines (No Dyn., No Fixed) on most test datasets.
  • Low-Data Regime Benefits: Even with as few as 40 labeled images, the pre-trained model achieved performance comparable to a from-scratch model trained on the full dataset.
  • Generalization: Pre-training improved generalization to unseen modalities (e.g., TOF MRI) and across different clinics.
  • Masking Strategy: Dynamic masking ratios between 60-90% performed well, and specific adaptations for CNNs (sparse convolutions, mask tokens) were beneficial.

Limitations and Future Work

  • Limited to Brain MRI: The current work focuses on brain MRI. Expanding to encompass the entire body across multiple imaging modalities would require substantially more data.
  • Pre-training Dataset Size: While their dataset is large for SSL in this domain, further scaling could potentially yield even greater improvements.
  • Intensity Augmentations: The success of Model Genesis with intensity augmentations suggests exploring similar techniques for MAEs to improve generalization across MRI sequences.
  • Data-Centric Approach: Future work could focus on data-centric approaches, such as more sophisticated filtering of raw clinical data, to enhance the quality and effectiveness of the pre-training process.

Summary updated

BibTeX
@inproceedings{wald2025revisiting,
  author = {Tassilo Wald and Constantin Ulrich and Stanislav Lukyanenko and Andrei Goncharov and Alberto Paderno and Leander Maerkisch and Paul F. Jäger and Klaus H. Maier-Hein},
  title = {{Revisiting MAE pre-training for 3D medical image segmentation}},
  booktitle = {IEEE/CVF Conference on Computer Vision and Pattern Recognition},
  year = {2025},
  doi = {10.1109/cvpr52734.2025.00489},
}