NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Revisiting MAE Pre-training for 3D Medical Image Segmentation

Tassilo Wald, Constantin Ulrich, Stanislav Lukyanenko, Andrei Goncharov, Alberto Paderno, Maximilian Miller, Leander Maerkisch, Paul F. Jaeger, Klaus H. Maier-Hein

Introduction

In the domain of medical imaging, the scarcity and high cost of expert-labeled data remain significant barriers to developing robust deep learning models. While Self-Supervised Learning (SSL) has fundamentally transformed fields like Natural Language Processing (NLP) and Computer Vision (CV) by leveraging vast quantities of unlabeled data, its impact on 3D medical image segmentation has been comparatively muted. Most practitioners continue to rely on training from scratch using the nnU-Net framework, as previous SSL attempts often failed to provide a consistent or meaningful performance boost over well-optimized baselines.

This research "revisits" Masked Autoencoders (MAE) for 3D medical imaging, identifying three critical pitfalls that have previously hindered SSL's progress: limited dataset sizes (often under 10,000 volumes), the use of outdated or sub-optimal backbones, and insufficient evaluation across diverse datasets. To address these, the authors introduce Spark3D, a framework that scales pre-training to nearly 40,000 brain MRI volumes and utilizes a modern Residual U-Net backbone, finally proving that SSL can substantially outperform the gold-standard nnU-Net baseline.

Spark3D: Optimizing MAE for 3D CNNs

The core of the Spark3D approach is the adaptation of the Masked Autoencoder (MAE) paradigm for 3D Convolutional Neural Networks (CNNs). While MAE was originally popularized using Vision Transformers (ViTs), CNNs present unique challenges—specifically, their inability to naturally handle the "holes" or missing data created by masking.

To overcome this, Spark3D incorporates several architectural innovations:

  • Sparse Convolutions: By employing sparse convolutions, the network is forced to process only the visible (unmasked) voxels, preventing the "leakage" of information from masked regions during the encoding phase.
  • Mask Tokens and Densification: Before the decoder stage, learnable mask tokens are inserted to fill the gaps. A specialized "densification convolution" layer (3x3x3) facilitates the transition from sparse encoder features to a dense representation suitable for the decoder's reconstruction task.
  • Dynamic Masking: Rather than using a static masking ratio, Spark3D employs a dynamic range, masking between 60% and 90% of the image. This variability during pre-training enhances the model's robustness and feature representation.

The choice of backbone is equally critical. Spark3D uses a Residual Encoder U-Net integrated directly into the nnU-Net framework. This ensures that the base model is already at the state-of-the-art level before any self-supervised pre-training is applied, providing a rigorous foundation for evaluating SSL gains.

Large-Scale Pre-training and Evaluation

The scale of the data used in this study sets a new benchmark for the field. The authors curated a massive pre-training dataset consisting of 39,168 3D brain MRI volumes sourced from clinical examinations across 44 different centers. This scale is roughly four times larger than typical SSL studies in this domain.

Evaluation was equally comprehensive. To ensure the generalizability of the learned representations, Spark3D was tested on 13 different downstream datasets (5 for development and 8 for final testing). These datasets cover a wide array of clinical scenarios, including multiple sclerosis lesion segmentation, brain metastases detection, stroke lesion (ISLES) and carotid vessel (Cosmos) segmentation, and anatomical structures like the hippocampus.

Performance and Ranking Stability

The results demonstrate a clear and consistent advantage for Spark3D. Across all primary test tasks, Spark3D outperformed the highly optimized nnU-Net baseline by an average of approximately 3 Dice points.

Spark3D achieves a significant improvement in Average DSC compared to both dynamic and fixed nnU-Net baselines and other SSL methods.

Beyond simple average improvements, the researchers conducted a head-to-head comparison with other popular SSL methods, including Models Genesis (MG), Volume Contrastive (VoCo), and Volume Fusion (VF). Spark3D consistently secured the top rank across nearly every benchmark, demonstrating superior stability and generalization.

Ranking distributions across 11 diverse datasets (D1-D11) show that Spark3D (green) consistently ranks as the top-performing method compared to other SSL approaches.

Furthermore, Spark3D showed exceptional data efficiency. In "low-data" regimes—where only 10 to 40 labeled images are available—the pre-trained model provided a massive performance boost over training from scratch. This makes the framework particularly valuable for clinical research involving rare diseases where labeled data is extremely scarce.

Discussion and Future Directions

The success of Spark3D offers several key insights for the medical imaging community. First, it highlights that the perceived failure of SSL in the past was largely due to sub-optimal backbones and insufficient data scale. When applied to a "well-configured" architecture like nnU-Net, the benefits of SSL become undeniable. Second, it proves that CNNs, when properly adapted with sparse convolutions, are just as capable as Transformers for MAE-style pre-training.

However, some limitations remain. The current pre-training is focused on Head and Neck MRIs. While generalization within brain pathologies was excellent, future work is needed to determine how these representations transfer to other anatomical regions like the abdomen or thorax. Additionally, the authors suggest that more refined data curation and the exploration of hybrid SSL objectives could further push the boundaries of 3D medical image segmentation.

Summary updated

BibTeX
@inproceedings{wald2025revisiting,
  author = {Tassilo Wald and Constantin Ulrich and Stanislav Lukyanenko and Andrei Goncharov and Alberto Paderno and Maximilian Miller and Leander Maerkisch and Paul F. Jaeger and Klaus H. Maier-Hein},
  title = {{Revisiting MAE Pre-training for 3D Medical Image Segmentation}},
  booktitle = {IEEE/CVF Conference on Computer Vision and Pattern Recognition},
  year = {2025},
  doi = {10.1109/cvpr52734.2025.00489},
}
Figure