Proposal for an Electron Antineutrino Disappearance Search Using High-Rate 8Li Production and Decay

Adriana Bungau, Andreas Adelmann, J. Alonso, William A. Barletta, R. J. Barlow, L. Bartoszek, L. Calabretta, A. Calanna, D. Campo, J. M. Conrad, Z. Djurcic, Y. Kamyshkov, M. H. Shaevitz, I. Shimizu, Tess Smidt, J. Spitz, M. O. Wascko, L. A. Winslow, Jianjun Yang

Abstract

This paper introduces a novel, high-intensity source of electron antineutrinos from the production and subsequent decay of $^8$Li. When paired with an existing ~1 kton scintillator-based detector, this $\approx$ 6.4 MeV source opens a wide range of possible searches for beyond standard model physics via studies of the inverse beta decay interaction. In particular, the experimental design described here has unprecedented sensitivity to electron antineutrino disappearance at $\Delta m^2 \sim 1 \text{ eV}^2$ and features the ability to distinguish between the existence of zero, one, and two sterile neutrinos.

Introduction

The Standard Model of particle physics describes neutrinos as existing in three distinct "flavors." However, persistent anomalies from experiments such as LSND and MiniBooNE have hinted at the existence of a fourth, "sterile" neutrino. Such a particle would not interact via the weak force but would participate in flavor oscillations at a mass scale of $\Delta m^2 \sim 1 \text{ eV}^2$. Confirming these oscillations requires an exceptionally intense neutrino source and a short-baseline detector setup to minimize systematic uncertainties.

The IsoDAR Experimental Design

The proposed IsoDAR (Isotope Decay-At-Rest) experiment addresses these requirements through a high-flux cyclotron and a specialized target system. The process begins with a compact cyclotron accelerating 5 mA of $H_2^+$ ions to 60 MeV/amu—a significant technical advancement over current commercial capabilities.

Schematic of the IsoDAR target assembly, showing the beam striking a beryllium target surrounded by a lithium-7 sleeve to produce lithium-8.

As shown in the figure above, the ion beam strikes a Beryllium ($^9$Be) target, generating a high neutron flux. These neutrons are captured by a surrounding sleeve of isotopically pure Lithium-7 ($^7$Li), producing Lithium-8 ($^8$Li). The subsequent beta decay of $^8$Li releases electron antineutrinos ($\bar{\nu}_e$) with a high average energy of 6.4 MeV and an endpoint near 13 MeV, effectively placing the signal above most natural backgrounds.

Detecting the "Oscillation Wave"

By positioning this compact source approximately 16 meters from a massive liquid scintillator detector like KamLAND, the experiment can measure neutrino flux as a function of distance ($L$) and energy ($E$). The primary signature of sterile neutrinos in this setup is the "oscillation wave"—a distinct pattern of peaks and valleys in neutrino disappearance across the detector volume.

Comparison of predicted oscillation signatures for (3+1) and (3+2) sterile neutrino models, demonstrating the distinct L/E dependence.

Because the $L/E$ dependence is so characteristic, the analysis can rely on the "shape" of the data rather than absolute flux measurements. This makes the discovery robust against common systematic errors associated with neutrino source intensity.

Expected Performance and Discovery Potential

Simulations using GEANT4 and established KamLAND detector parameters indicate that IsoDAR could collect over 820,000 inverse beta decay (IBD) interactions over a five-year period. This massive dataset would allow for:

  • Rapid Discovery: Ruling out current sterile neutrino models at a $5\sigma$ confidence level within just four months of operation.
  • Model Differentiation: The high statistics enable the experiment to distinguish between models containing one (3+1) versus two (3+2) sterile neutrinos, as illustrated by the differing oscillation patterns in the simulated data.
  • High Sensitivity: Reaching a sensitivity of $20\sigma$ for the current best-fit sterile neutrino parameters after five years.

Conclusion

While the engineering of a 5 mA cyclotron beam presents challenges regarding space-charge effects, the potential scientific payoff is immense. IsoDAR offers a definitive path to resolving the sterile neutrino anomaly and provides a high-precision sample of neutrino-electron scatters to probe other electroweak physics beyond the Standard Model.

Summary updated

Abstract

This paper introduces a novel, high-intensity source of electron antineutrinos from the production and subsequent decay of 8Li. When paired with an existing ~1 kton scintillator-based detector, this =6.4 MeV source opens a wide range of possible searches for beyond standard model physics via studies of the inverse beta decay interaction. In particular, the experimental design described here has unprecedented sensitivity to electron antineutrino disappearance at $Δm^2\sim$ 1 eV$^2$ and features the ability to distinguish between the existence of zero, one, and two sterile neutrinos.
BibTeX
@inproceedings{bungau2012proposal,
  author = {Adriana Bungau and Andreas Adelmann and J. Alonso and William A. Barletta and R. J. Barlow and L. Bartoszek and L. Calabretta and A. Calanna and D. Campo and J. M. Conrad and Z. Djurcic and Y. Kamyshkov and M. H. Shaevitz and I. Shimizu and Tess Smidt and J. Spitz and M. O. Wascko and L. A. Winslow and Jianjun Yang},
  title = {{Proposal for an Electron Antineutrino Disappearance Search Using High-Rate 8Li Production and Decay}},
  booktitle = {Physical},
  year = {2012},
  doi = {10.1103/physrevlett.109.141802},
}
Figure