Abstract
This paper develops a new vascular respiratory motion compensation algorithm, Motion-Related Compensation (MRC), to conduct vascular respiratory motion compensation by extrapolating the correlation between invisible vascular and visible non-vascular. Robot-assisted vascular intervention can significantly reduce the radiation exposure of surgeons. In robot-assisted image-guided intervention, blood vessels are constantly moving/deforming due to respiration, and they are invisible in the X-ray images unless contrast agents are injected. The vascular respiratory motion compensation technique predicts 2D vascular roadmaps in live X-ray images. When blood vessels are visible after contrast agents injection, vascular respiratory motion compensation is conducted based on the sparse Lucas-Kanade feature tracker. An MRC model is trained to learn the correlation between vascular and non-vascular motions. During the intervention, the invisible blood vessels are predicted with visible tissues and the trained MRC model. Moreover, a Gaussian-based outlier filter is adopted for refinement. Experiments on in-vivo data sets show that the proposed method can yield vascular respiratory motion compensation in 0.032 sec, with an average error 1.086 mm. Our real-time and accurate vascular respiratory motion compensation approach contributes to modern vascular intervention and surgical robots.
Introduction
In robot-assisted vascular surgery, such as stent placement or tumor treatment, surgeons rely on X-ray fluoroscopy for guidance. However, a major challenge is that blood vessels are only visible when a contrast agent is injected, and these agents wash away quickly. Once the vessels disappear, surgeons are left with a "static roadmap"—a fixed overlay of the vessel structure.
The primary obstacle to maintaining an accurate roadmap is respiratory motion. As the patient breathes, organs like the liver move and deform, causing the static roadmap to become unaligned with the actual vessels. This paper introduces Motion-Related Compensation (MRC), a real-time algorithm that predicts the movement of "invisible" blood vessels by tracking the motion of visible surrounding tissues, thereby maintaining a dynamic and accurate roadmap.
Methodology
The MRC algorithm employs a three-stage pipeline to achieve high-accuracy compensation with low computational latency:
- Sparse Corners Alignment: To ensure real-time performance (31 Hz), the system avoids dense pixel tracking. Instead, it uses Shi-Tomasi corner detection to identify salient features in the tissue and tracks them using the Lucas-Kanade (LK) optical flow method.
- Motion-Related Model (MRC): This core component learns the correlation between vascular and non-vascular motions. While the contrast agent is visible, the system calculates the Pearson correlation coefficient between the motion of vascular points and non-vascular points, building a linear regression model to predict vessel movement from visible tissue displacement.
- Gaussian-based Outlier Filtering (GOF): To handle tracking noise, a refinement step assumes predicted motions follow a Gaussian distribution. A $3\sigma$ bound is used to discard outliers, ensuring the final roadmap remains stable.
Experimental Results
The algorithm was evaluated using 13 in-vivo sequences, including human data from hepatic vascular surgeries (TACE and TIPS procedures) and animal data from a porcine model. Ground truth was established by manual labeling of vascular centerlines on 222 frames.
The MRC method achieved a processing speed of 0.032 seconds (31 Hz), meeting the requirements for live surgery. Quantitatively, the average tracking error was 1.086 mm, significantly outperforming previous methods like WSSD and CRD. Clinical scoring by two clinicians also favored the MRC method, which received a mean score of 3.962/5.
Discussion and Conclusion
The success of the MRC algorithm stems from the insight that while vascular and non-vascular tissues do not move identically, their motions are highly correlated. By learning this linear relationship, the model provides a robust and fast solution for respiratory compensation. Unlike non-linear methods such as Gaussian Process Regression (GPR), the linear MRC model is computationally efficient enough for real-time surgical applications.
Future work will aim to fuse multiple frames for a more complete vascular mask and incorporate heartbeat-induced motion compensation to support cardiac interventions. In conclusion, the MRC approach offers a real-time, accurate solution that significantly contributes to the advancement of robot-assisted vascular surgery.
Summary updated