On Retrospective k-space Subsampling schemes For Deep MRI Reconstruction

George Yiasemis, Clara I. Sánchez, Jan-Jakob Sonke, Jonas TeuwenarXiv 2023

TL;DR

This paper explores how different k-space sampling patterns affect the quality of MRI reconstructions when using deep learning. They found that non-rectilinear and non-Cartesian sampling schemes consistently produce better results, especially at higher acceleration factors, suggesting a path towards faster and higher-quality MRI scans.

What Problem Does This Paper Address?

Magnetic Resonance Imaging (MRI) is a powerful diagnostic tool, but acquiring high-resolution images takes a long time because it involves collecting a lot of data in k-space. To speed this up, researchers often "subsample" the k-space data, meaning they collect less data and then use algorithms to reconstruct the full image. A common subsampling method is rectilinear Cartesian, where data is collected in a grid-like fashion. However, this can lead to imprecise reconstructions, particularly at high acceleration factors (meaning a lot of data is skipped). This paper investigates whether alternative k-space sampling patterns, beyond the standard rectilinear approach, can lead to significantly better deep learning-based MRI reconstructions.

Methods

The authors employed a state-of-the-art deep learning model called the Recurrent Variational Network (RecurrentVarNet) for MRI reconstruction. This model is designed to iteratively solve the inverse problem of reconstructing an image from undersampled k-space data. They retrospectively applied eight different k-space subsampling schemes to fully-sampled MRI data. These schemes included:

  • Four Cartesian-rectilinear schemes: Random, Equispaced, Equispaced+, and Gaussian 1D. These are variations on the standard grid-like sampling.
  • Two Cartesian non-rectilinear schemes: Variable Density Poisson Disk (VDPD) and Gaussian 2D. These sample points on a Cartesian grid but with varying densities, often favoring the center.
  • Two non-Cartesian schemes: Radial and Spiral. These sample k-space along spokes or helical paths, respectively, which are not aligned with a grid.

They conducted experiments in two frameworks:

  1. Scheme-specific: A separate RecurrentVarNet was trained and evaluated for each specific subsampling scheme and dataset.
  2. Multi-scheme: A single RecurrentVarNet was trained on data subsampled by any of the eight schemes and then evaluated on data subsampled by all schemes.

Datasets

The study utilized three publicly available, large-scale MRI datasets:

  • fastMRI Knee dataset: Contains knee MRI scans.
  • fastMRI Brain dataset: Contains brain MRI scans.
  • Calgary-Campinas (CC) brain dataset: Another brain MRI dataset.

All datasets consisted of 2D multi-coil, fully-sampled Cartesian k-space data. No new datasets were introduced.

Key Insights and Ideas

  • Non-rectilinear is generally better: The most significant finding is that deep learning models trained and evaluated on data subsampled with non-rectilinear (VDPD, Gaussian 2D) or non-Cartesian (Radial, Spiral) schemes consistently produced higher-quality reconstructions compared to those trained on rectilinear schemes, especially at higher acceleration factors (R=4 and R=8).
  • Why non-rectilinear works: These non-standard schemes allow for more "incoherent" sampling, meaning the missing data points are less correlated and less predictable. This reduces the reliance on specific sampling patterns and allows for better center oversampling, which contains crucial information like image contrast and overall shape.
  • Multi-scheme training helps rectilinear: While non-rectilinear schemes excel on their own, training a single model on data from all schemes (multi-scheme setup) significantly improved the reconstruction quality for data that was rectilinearly subsampled, compared to training a scheme-specific model. This suggests a way to leverage the benefits of diverse sampling for improving standard acquisition methods.
  • Model choice matters less than sampling: The study also showed that these findings held true even when using a different deep learning architecture (Recurrent Inference Machine - RIM), indicating that the subsampling scheme itself is a primary driver of reconstruction quality.

Key Results

  • Quantitative improvements: Non-rectilinear schemes (VDPD, Gaussian 2D) consistently outperformed rectilinear schemes across various metrics (SSIM, PSNR, SNR, HFEN, NMSE) for all datasets and acceleration factors. For example, at R=8, models trained on VDPD or Gaussian 2D achieved higher average SSIM and PSNR values.
  • Qualitative improvements: Visual inspection of reconstructed images (Figures 5, 6, A.1) clearly showed that reconstructions from non-rectilinearly subsampled data had fewer artifacts and were sharper, especially at higher acceleration factors, compared to rectilinear subsampling.
  • Multi-scheme benefits: In the multi-scheme setup, reconstructions of rectilinearly subsampled data showed noticeable improvements (e.g., SSIM/pSNR increase, HFEN/NMSE decrease) compared to scheme-specific training, as detailed in Table 1.

Limitations and Future Work

  • Retrospective vs. Prospective: The study relied on retrospective subsampling, meaning they simulated undersampling on already fully-sampled data. The authors acknowledge that prospective subsampling (where data is actually collected with a specific pattern) might introduce different challenges and trade-offs, especially concerning acquisition speed and hardware constraints.
  • ACS Region Sampling: The way the Autocalibration Signal (ACS) region was handled in the retrospective setup might differ from prospective scenarios, potentially affecting contrast.
  • Future Directions: The authors suggest future work should involve prospective subsampling experiments to validate these findings in real-world acquisition settings. They also propose exploring advanced non-Cartesian trajectories and investigating how to handle non-Cartesian data within a deep learning pipeline.

Summary updated

Abstract

Acquiring fully-sampled MRI $k$-space data is time-consuming, and collecting accelerated data can reduce the acquisition time. Employing 2D Cartesian-rectilinear subsampling schemes is a conventional approach for accelerated acquisitions; however, this often results in imprecise reconstructions, even with the use of Deep Learning (DL), especially at high acceleration factors. Non-rectilinear or non-Cartesian trajectories can be implemented in MRI scanners as alternative subsampling options. This work investigates the impact of the $k$-space subsampling scheme on the quality of reconstructed accelerated MRI measurements produced by trained DL models. The Recurrent Variational Network (RecurrentVarNet) was used as the DL-based MRI-reconstruction architecture. Cartesian, fully-sampled multi-coil $k$-space measurements from three datasets were retrospectively subsampled with different accelerations using eight distinct subsampling schemes: four Cartesian-rectilinear, two Cartesian non-rectilinear, and two non-Cartesian. Experiments were conducted in two frameworks: scheme-specific, where a distinct model was trained and evaluated for each dataset-subsampling scheme pair, and multi-scheme, where for each dataset a single model was trained on data randomly subsampled by any of the eight schemes and evaluated on data subsampled by all schemes. In both frameworks, RecurrentVarNets trained and evaluated on non-rectilinearly subsampled data demonstrated superior performance, particularly for high accelerations. In the multi-scheme setting, reconstruction performance on rectilinearly subsampled data improved when compared to the scheme-specific experiments. Our findings demonstrate the potential for using DL-based methods, trained on non-rectilinearly subsampled measurements, to optimize scan time and image quality.

Empirical ResultsBrowse all benchmarks →

BenchmarkMethodMetricScoreProtocol / Evidence
fastMRI kneeRecurrentVarNet, multi-scheme trainingSSIM0.7%split: test · training=multi-scheme · acceleration=R=8 · sampling-scheme=rectilinear
Source quote
L415: \multirow{2}{*}{FastMRI Knee} │ Rectilinear │ 0.1% │ 0.5% │ -0.7% │ 0.3% │ 0.8% │ -3.2% │ 0.7% │ 1.4% │ -9.4%
Calgary-Campinas · Calgary CampinasRecurrentVarNet, multi-scheme trainingSSIM3.7%split: test · training=multi-scheme · acceleration=R=8 · sampling-scheme=rectilinear
Source quote
L419: \multirow{2}{*}{Calgary Campinas} │ Rectilinear │ 0.3% │ 1.6% │ -13.9% │ 1.2% │ 2.7% │ -18.5% │ 3.7% │ 5.0% │ -26.0%
fastMRI kneeRecurrentVarNet, multi-scheme trainingpSNR1.4%split: test · training=multi-scheme · acceleration=R=8 · sampling-scheme=rectilinear
Source quote
L415: \multirow{2}{*}{FastMRI Knee} │ Rectilinear │ 0.1% │ 0.5% │ -0.7% │ 0.3% │ 0.8% │ -3.2% │ 0.7% │ 1.4% │ -9.4%
fastMRI BrainRecurrentVarNet, multi-scheme trainingpSNR0.7%split: test · training=multi-scheme · acceleration=R=8 · sampling-scheme=rectilinear
Source quote
L417: \multirow{2}{*}{FastMRI Brain} │ Rectilinear │ 0.0% │ 0.3% │ -2.6% │ 0.1% │ 0.2% │ -1.6% │ 0.3% │ 0.7% │ -4.8%
Calgary-Campinas · Calgary CampinasRecurrentVarNet, multi-scheme trainingpSNR5.0%split: test · training=multi-scheme · acceleration=R=8 · sampling-scheme=rectilinear
Source quote
L419: \multirow{2}{*}{Calgary Campinas} │ Rectilinear │ 0.3% │ 1.6% │ -13.9% │ 1.2% │ 2.7% │ -18.5% │ 3.7% │ 5.0% │ -26.0%
BibTeX
@misc{yiasemis2023retrospective,
  author = {George Yiasemis and Clara I. Sánchez and Jan-Jakob Sonke and Jonas Teuwen},
  title = {{On Retrospective k-space Subsampling schemes For Deep MRI Reconstruction}},
  year = {2023},
  eprint = {2301.08365},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2301.08365},
}