Noncontact Detection of Respiration Rate Based on Forward Scatter Radar

Fan Yang, Zhiming He, Yuanhua Fu, Liang Li, Kui Jiang, Fangyan Xie

TL;DR

This paper introduces a novel noncontact respiration rate detection system using Forward Scatter Radar (FSR). By analyzing changes in Radar Cross Section (RCS) due to breathing, the system accurately measures respiration rates even when the subject is not perfectly oriented towards the radar, overcoming a key limitation of existing methods.

What Problem Does This Paper Address?

Accurate, noncontact monitoring of human respiration is crucial for various applications, including medical diagnostics (e.g., sleep apnea, SIDS detection) and safety systems (e.g., in-car monitoring). While radar-based methods offer advantages over contact sensors, existing techniques often struggle with subjects in random orientations. This is because many rely on detecting subtle chest wall micromotions, which are highly dependent on precise antenna alignment with the chest. When a person moves, sleeps on their side, or twists, the radar's ability to capture these micro-movements diminishes, leading to detection errors. This paper aims to solve this by proposing a method that is less sensitive to orientation, focusing instead on the overall change in the body's radar signature during breathing.

Methods

The core of the proposed method is a Forward Scatter Radar (FSR) system. Unlike traditional radar, FSR utilizes a bistatic configuration where the transmitter and receiver are positioned on opposite sides of the target. The key insight is that human respiration causes changes in chest and abdominal volume, which in turn alters the body's Radar Cross Section (RCS). This change in RCS directly affects the amplitude of the received signal.

The authors derive a theoretical model relating the received signal's amplitude to the RCS changes during inhalation and exhalation. They then propose using envelope detection on the received signal to extract a "respiration curve." This curve, representing the amplitude modulation caused by breathing, can then be analyzed to determine the respiration rate. The system uses a single-frequency continuous wave (CW) signal, simplifying the hardware compared to Ultra-Wideband (UWB) systems.

Datasets

The paper does not explicitly mention or use pre-existing datasets for training or evaluation. Instead, the authors conducted their own experiments to collect data.

Key Insights and Ideas

  • RCS Modulation as a Breathing Indicator: The fundamental idea that breathing-induced changes in body shape lead to measurable variations in Radar Cross Section (RCS) is central. This shifts the focus from micro-motions to macro-changes in the radar signature.
  • Orientation Insensitivity of FSR: The FSR configuration, particularly with a bistatic angle approaching 180°, proves to be less sensitive to the subject's orientation compared to monostatic systems relying on chest micromovements. This is a significant advantage for real-world applications where subject posture is unpredictable.
  • Envelope Detection for Respiration Curve: Using envelope detection on the amplitude-modulated received signal is an effective way to isolate the breathing pattern, even with low signal power.
  • Robustness to Clothing: The FSR system demonstrates robustness to different clothing types and thicknesses, as shown by experiments conducted in both winter and summer with varying layers of clothing. This is attributed to the FSR's sensitivity to overall body shape changes rather than surface details.

Key Results

The paper presents experimental results from two main scenarios: an anechoic chamber and a common room.

  • Anechoic Chamber: The FSR system successfully detected respiration rates. The received signal showed clear amplitude modulation corresponding to breathing. Envelope detection yielded a respiration curve that matched the theoretical model.
  • Common Room: The system was tested with a subject at various orientation angles (0°, 30°, 60°, 90°). The FSR system accurately detected respiration rates across all tested angles, demonstrating its orientation insensitivity. For example, at 0°, the respiration rate was 22.5 breaths per minute, and at 90°, it was 19.2 breaths per minute.
  • Comparison with Contact Sensor: When compared with a PVDF contact sensor, the FSR system showed good agreement in respiration rate detection, even at a 90° orientation. While waveform differences were observed at 90° due to RCS variations with orientation, the fundamental breathing pattern was still captured.
  • Theoretical Model Validation: The experimental results generally aligned well with the derived theoretical model, with a small error attributed to the human body not being a perfect conductor.

Limitations and Future Work

  • Low Signal Amplitude: The received signal power in the experiments was noted to be very low (in the microvolt range), which might pose challenges for practical implementation in noisy environments.
  • Distinguishing Random Motion: While the paper states that random physical motion is distinguishable from respiration due to its shorter duration, further work might be needed to robustly filter out all types of unwanted motion artifacts.
  • Future Applications: The authors suggest that this FSR technique has significant practical value for applications such as sleep monitoring (integrating with cell phones and routers) and driver monitoring systems (cooperating with car systems). Further development could focus on miniaturization and integration into everyday devices.

Summary updated

Abstract

Bioradar-based noncontact breathing detection technology has been widely studied due to its superior detection performance. In this paper, a breath detection mechanism based on the change in radar cross section (RCS) is proposed by using a forward scatter radar and the deduction of the mathematical model of the received signal. Furthermore, we completed human breathing detection experiments in an anechoic chamber and in an ordinary chamber; we obtained the breathing rate through envelope detection in cases where the human orientation angle was 0, 30, 60, and 90°. The analysis of the measured data shows that the theoretical model fits well with the measured results. Compared with the existing single-base radar detection schemes, the proposed scheme can detect human respiratory rates in different orientations.
BibTeX
@inproceedings{yang2019noncontact,
  author = {Fan Yang and Zhiming He and Yuanhua Fu and Liang Li and Kui Jiang and Fangyan Xie},
  title = {{Noncontact Detection of Respiration Rate Based on Forward Scatter Radar}},
  booktitle = {Sensors},
  year = {2019},
  url = {https://openreview.net/forum?id=poz80Bx1fri},
}
Figure