Non-rigid Registration of 3D Multi-channel Microscopy Images of Cell Nuclei

Siwei Yang, Daniela Köhler, Kathrin Teller, Thomas Cremer, Patricia Le Baccon, Edith Heard, Roland Eils, Karl Rohr

Abstract

We present an intensity-based non-rigid registration approach for normalizing 3D multi-channel microscopy images of cell nuclei. A main problem with cell nuclei images is that the intensity structure of different nuclei differs very much, thus an intensity-based registration scheme cannot be used directly. Instead, we first perform a segmentation of the images, smooth them by a Gaussian filter, and then apply an intensity-based algorithm. To improve the convergence rate of the algorithm, we propose an adaptive step length optimization scheme and also employ a multi-resolution scheme. Our approach has been successfully applied using 2D cell-like synthetic images, 3D phantom images as well as 3D multi-channel microscopy images representing different chromosome territories and gene regions (BACs). We also describe an extension of our approach which is applied for the registration of 3D+t (4D) image series of moving cell nuclei.
BibTeX
@inproceedings{yang2006non,
  author = {Siwei Yang and Daniela Köhler and Kathrin Teller and Thomas Cremer and Patricia Le Baccon and Edith Heard and Roland Eils and Karl Rohr},
  title = {{Non-rigid Registration of 3D Multi-channel Microscopy Images of Cell Nuclei}},
  booktitle = {International Conference on Medical Image Computing and Computer-Assisted Intervention},
  year = {2006},
  doi = {10.1007/11866565\_111},
}