Non-inferiority of Deep Learning Model to Segment Acute Stroke on Non-contrast CT Compared to Neuroradiologists

Sophie Ostmeier, Jeremy J. Heit, Brian Axelrod, Li-Jia Li, Greg Zaharchuk, Benjamin F. J. Verhaaren, Abdelkader Mahammedi, Soren Christensen, Maarten G. Lansberg

Abstract

In the management of acute ischemic stroke (AIS), rapid and accurate identification of the ischemic core is critical for treatment decisions. While non-contrast CT (NCCT) is the most accessible imaging modality, its interpretation is challenged by subtle early changes and high inter-observer variability. This study presents a 3D convolutional neural network (CNN) designed to segment stroke lesions on NCCT by leveraging brain symmetry. Using a non-inferiority framework, the researchers demonstrate that the model's performance is comparable to that of expert neuroradiologists, suggesting its potential as a reliable tool for standardizing stroke assessment in emergency settings.

Introduction

"Time is brain" is the guiding principle in treating Acute Ischemic Stroke. Determining the extent of the "ischemic core"—irreversibly damaged brain tissue—is essential for selecting patients for therapies like mechanical thrombectomy. Although MRI and CT Perfusion are the gold standards for core estimation, they are often unavailable in resource-limited settings. Consequently, NCCT remains the primary imaging tool in over 65% of cases. However, the low signal-to-noise ratio of early ischemic changes on NCCT leads to significant variability in interpretation, even among specialists. This research explores whether a deep learning model can provide automated, expert-level segmentation of these subtle lesions.

Methods

The study utilized a 3D nnU-Net architecture, a robust framework for medical image segmentation. Two key technical innovations were implemented:

  • Symmetry Awareness: Recognizing that stroke typically manifests as an asymmetry between brain hemispheres, the model was provided with two input channels: the original NCCT and its mirrored version. This allows the network to explicitly learn features of hemispheric asymmetry.
  • Non-Inferiority Framework: The evaluation focused on whether the model's agreement with an expert was statistically non-inferior to the agreement between two human experts.
  • Loss Function Optimization: A combination of Soft Dice and Focal Loss was used to address the class imbalance inherent in segmenting small stroke lesions within the large volume of the brain.

Dataset and Patient Characteristics

The model was trained and evaluated using data from the DEFUSE 3 trial, involving 232 patients with large vessel occlusion strokes. The dataset was split into 200 patients for training/validation and 32 patients for independent testing. Ground truth segmentations were provided by three independent neuroradiologists (Experts A, B, and C), with Expert A's labels serving as the primary training target.

Table 1: Patient characteristics and imaging volumes for the training and testing datasets derived from the DEFUSE 3 trial.

Results

The primary finding of the study is that the deep learning model achieved non-inferiority to human experts across various metrics. For the primary performance metrics, the model achieved a Surface Dice at 5mm tolerance (SDT 5mm) of 0.46 ± 0.09 and a Dice score of 0.47 ± 0.13 when compared to Expert A.

Table 2: Performance metrics comparing model-expert agreement to inter-expert agreement, showing non-inferiority across multiple categories.

Statistical analysis confirmed that model-expert agreement was non-inferior to inter-expert agreement (p < 0.05) for volume, overlap, and distance metrics. Notably, the correlation between model-predicted volumes and expert volumes (R=0.75 to 0.79) often exceeded the correlation between the human experts themselves (R=0.63 to 0.74), highlighting the model's consistency. The inclusion of mirrored inputs was a critical factor, significantly improving performance over a standard 3D baseline.

Discussion and Limitations

The results suggest that deep learning can act as a "consistent peer" to neuroradiologists, potentially democratizing specialist-level NCCT interpretation. However, several limitations remain:

  • Sample Size: The independent test set of 32 patients is relatively small.
  • Selection Bias: Data was limited to the DEFUSE 3 trial cohort (6-16 hours post-stroke), and performance on "ultra-early" strokes (under 6 hours) is unknown.
  • Subjectivity of Ground Truth: The inherent variability in expert interpretation means that defining an absolute gold standard remains challenging.

Future work should focus on prospective clinical validation to determine if automated segmentation improves treatment speed and patient outcomes in real-world emergency departments.

Summary updated

Abstract

To determine if a convolutional neural network (CNN) deep learning model can accurately segment acute ischemic changes on non-contrast CT compared to neuroradiologists. Non-contrast CT (NCCT) examinations from 232 acute ischemic stroke patients who were enrolled in the DEFUSE 3 trial were included in this study. Three experienced neuroradiologists independently segmented hypodensity that reflected the ischemic core on each scan. The neuroradiologist with the most experience (expert A) served as the ground truth for deep learning model training. Two additional neuroradiologists (experts B and C) segmentations were used for data testing. The 232 studies were randomly split into training and test sets. The training set was further randomly divided into 5 folds with training and validation sets. A 3-dimensional CNN architecture was trained and optimized to predict the segmentations of expert A from NCCT. The performance of the model was assessed using a set of volume, overlap, and distance metrics using non-inferiority thresholds of 20%, 3ml, and 3mm. The optimized model trained on expert A was compared to test experts B and C. We used a one-sided Wilcoxon signed-rank test to test for the non-inferiority of the model-expert compared to the inter-expert agreement. The final model performance for the ischemic core segmentation task reached a performance of 0.46+-0.09 Surface Dice at Tolerance 5mm and 0.47+-0.13 Dice when trained on expert A. Compared to the two test neuroradiologists the model-expert agreement was non-inferior to the inter-expert agreement, p < 0.05. The CNN accurately delineates the hypodense ischemic core on NCCT in acute ischemic stroke patients with an accuracy comparable to neuroradiologists.