Greg Zaharchuk

Greg Zaharchuk

Stanford University
1 previous affiliation
383Machine learning papers tracked by Lacuna
Is this you?

Research Overview

Greg Zaharchuk focuses on advanced neuroimaging techniques, integrating magnetic resonance imaging (MRI) and positron emission tomography (PET) to evaluate brain hemodynamics and pathology. His trajectory spans the development of non-invasive perfusion imaging methods to the application of deep learning for medical image synthesis and analysis. Currently, his work addresses the generation of diagnostic-quality imaging from reduced-dose or multi-contrast data using generative artificial intelligence.

Research Trajectory

Zaharchuk’s early research centered on evaluating and refining methods for measuring cerebral hemodynamics. He contributed to foundational comparative evaluations of imaging modalities, such as the Comparative Overview of Brain Perfusion Imaging Techniques, which assessed the respective advantages of PET, SPECT, CT, and MRI for characterizing brain pathology. Building on this foundation, he investigated non-invasive alternatives for vascular assessment. In Arterial Spin-Labeling MRI Can Identify the Presence and Intensity of Collateral Perfusion in Patients With Moyamoya Disease, he demonstrated that arterial spin-labeling (ASL) could reliably predict collateral flow without the need for invasive digital subtraction angiography. Concurrently, he participated in major clinical evaluations of stroke interventions, including the DEFUSE 2 prospective cohort study detailed in MRI profile and response to endovascular reperfusion after stroke (DEFUSE 2).

By 2014, Zaharchuk was guiding the development of novel quantitative imaging techniques. He oversaw the introduction of an MR fingerprinting approach to compute microvascular characteristics, such as cerebral blood volume and oxygenation, in MR vascular fingerprinting: A new approach to compute cerebral blood volume, mean vessel radius, and oxygenation maps in the human brain.

Around 2015, his focus expanded significantly into hybrid imaging modalities, particularly advancing the research direction of Time-of-Flight Localization in Positron Emission Tomography. He led investigations into the clinical advantages of simultaneous Time-of-Flight (TOF) PET-MRI systems over standard PET/CT. In The potential of TOF PET-MRI for reducing artifacts in PET images, his team demonstrated that the superior timing resolution of TOF PET-MRI significantly reduced common image artifacts, particularly near dental implants and the pelvis. This hybrid approach also proved valuable in oncology; in Conspicuity of Malignant Lesions on PET/CT and Simultaneous Time-Of-Flight PET/MRI, the combination of MRI's soft-tissue contrast and TOF-enabled PET sensitivity improved the detection of malignant lesions, especially those with lower metabolic activity. This work naturally intersected with the broader area of Synthetic CT Generation for PET MRI Attenuation Correction. During this period, Zaharchuk also continued his involvement in large-scale stroke research, participating in the landmark DEFUSE 3 trial, which established the efficacy of thrombectomy 6 to 16 hours post-stroke when patients were selected via perfusion imaging, as reported in Thrombectomy for Stroke at 6 to 16 Hours with Selection by Perfusion Imaging.

Beginning in 2018, Zaharchuk began integrating deep learning into neuroradiology to address both clinical efficiency and patient safety. He co-authored a comprehensive review on the transition of convolutional neural networks into clinical practice in Deep Learning in Neuroradiology. Applying these techniques to clinical challenges, he explored methods to minimize chemical contrast agents, demonstrating the feasibility of dose reduction in Deep learning enables reduced gadolinium dose for contrast‐enhanced brain MRI. Recognizing the practical realities of clinical datasets, his group also developed robust models capable of handling incomplete data. In Handling missing MRI sequences in deep learning segmentation of brain metastases: a multicenter study, they utilized input-level dropout to train networks that could accurately segment lesions even when standard MRI sequences were missing, contributing to the research area of Overcoming the Manual Segmentation Bottleneck in Medical Imaging.

In recent years, Zaharchuk has advanced the synthesis of medical images across modalities, a key component of the research direction Fusing Electrophysiological and Hemodynamic Neuroimaging. He directed the development of the Multi-contrast Multi-scale Transformer (MMT) in One Model to Synthesize Them All: Multi-Contrast Multi-Scale Transformer for Missing Data Imputation, framing MRI imputation as a sequence-to-sequence problem to synthesize missing contrasts. His work frequently targets non-invasive diagnostics, particularly in the area of Non-Invasive Perfusion Imaging with Endogenous Magnetic Tracers. He validated early-frame PET/MRI for cerebral blood flow quantification in cognitive impairment in Early-Frame [18F]Florbetaben PET/MRI for Cerebral Blood Flow Quantification in Patients with Cognitive Impairment: Comparison to an [15O]Water Gold Standard. Pushing this concept further, his team synthesized diagnostic 15O-water PET cerebral blood flow maps directly from multi-contrast MRI using attention-based networks in Turning brain MRI into diagnostic PET: 15O-water PET CBF synthesis from multi-contrast MRI via attention-based encoder-decoder networks. They also developed 3D deep learning frameworks to predict Alzheimer's hallmarks from standard MRI in Deep Learning-Based Prediction of PET Amyloid Status Using Multi-Contrast MRI.

By 2025, Zaharchuk's research heavily features generative AI for image enhancement and synthesis, contributing to the direction of Non-Contrast Medical Imaging via Endogenous Signals and Synthesis. His group demonstrated that deep learning could digitally boost contrast in standard brain MRIs to match double-dose imaging without additional gadolinium in Deep-Learning Based Contrast Boosting Improves Lesion Visualization and Image Quality: A Multi-Center Multi-Reader Study on Clinical Performance with Standard Contrast Enhanced MRI of Brain Tumors. They also introduced SPHERE, a physics-grounded framework to reverse-engineer pre-contrast MRI images from post-contrast scans in Staged and Physics-Grounded Learning Framework with Hyperintensity Prior for Pre-Contrast MRI Synthesis. Additionally, they explored score-based diffusion models to synthesize full-dose FDG brain PET from MRI for epilepsy patients in Score-based Generative Diffusion Models to Synthesize Full-dose FDG Brain PET from MRI in Epilepsy Patients. Expanding beyond imaging, Zaharchuk has recently applied large language models to clinical informatics; in COPE: Chain-Of-Thought Prediction Engine for Open-Source Large Language Model Based Stroke Outcome Prediction from Clinical Notes, his team introduced a framework that decouples clinical reasoning from score extraction to predict stroke outcomes directly from unstructured text.

Current Directions

Zaharchuk’s most recent work focuses heavily on the application of generative artificial intelligence to solve complex challenges in medical imaging and clinical informatics. A primary theme is cross-modality image synthesis, where his group uses advanced architectures—such as diffusion models and multi-scale transformers—to generate high-fidelity PET scans from MRI data, or to synthesize pre-contrast images from post-contrast scans. This aligns with a broader effort to reduce patient exposure to radiation and chemical contrast agents while maintaining or improving diagnostic accuracy. Additionally, recent papers indicate an expanding interest in leveraging open-source large language models to extract predictive insights from unstructured clinical notes, creating cost-effective and privacy-preserving tools for clinical decision support.

Profile updated

TitleVenueYear
Evaluation of Image‐Level Harmonization Methods for Multi‐Center <scp>MR</scp> NeuroimagingJournal of Magnetic Resonance Imaging2026
CheXmix: Unified Generative Pretraining for Vision Language Models in Medical ImagingCvpr 2026 Findings2026
Foundational Model for Real-Time Neuroimaging Spatial NormalizationProceedings on Cd-rom - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition2025
Optimization of deep learning–based denoising for arterial spin labeling: Effects of averaging and training strategiesMagnetic2025
Arterial Spin-Labeling MRI Identifies Abnormal Perfusion Metric at the Gray Matter/CSF Interface in Cerebral Small Vessel DiseaseAmerican2025
Score-based Generative Diffusion Models to Synthesize Full-dose FDG Brain PET from MRI in Epilepsy PatientsarXiv2025
Developing a Public Dataset for 15O-H2O PET/MRI with ASL Perfusion in Healthy Controls and Moyamoya Patients: Methods, Validation &amp; ApplicationsProceedings on Cd-rom - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition2025
Impact of Defacement on Deep Learning-based Amyloid Prediction with Multi-contrast MRIProceedings on Cd-rom - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition2025
Abstract WP196: Comparing hypodensity and volume measurements for ischemic stroke patients in admission CT between CTP ischemic core, DWI, and deep learning based CT regions of interestStroke2025
Image SNR Enhancement for a Short Axial FOV Brain PET System Using Generative Deep LearningIEEE Transactions on Radiation and Plasma Medical Sciences2025

Browse all 383 papers

See something wrong? Report a mistake