Abstract
Musculoskeletal diseases such as sarcopenia and osteoporosis are major obstacles to health during aging. Although dual-energy X-ray absorptiometry (DXA) and computed tomography (CT) can be used to evaluate musculoskeletal conditions, frequent monitoring is difficult due to the cost and accessibility (as well as high radiation exposure in the case of CT). We propose a method (named MSKdeX) to estimate fine-grained muscle properties from a plain X-ray image, a low-cost, low-radiation, and highly accessible imaging modality, through musculoskeletal decomposition leveraging fine-grained segmentation in CT. We train a multi-channel quantitative image translation model to decompose an X-ray image into projections of CT of individual muscles to infer the lean muscle mass and muscle volume. We propose the object-wise intensity-sum loss, a simple yet surprisingly effective metric invariant to muscle deformation and projection direction, utilizing information in CT and X-ray images collected from the same patient. While our method is basically an unpaired image-to-image translation, we also exploit the nature of the bone's rigidity, which provides the paired data through 2D-3D rigid registration, adding strong pixel-wise supervision in unpaired training. Through the evaluation using a 539-patient dataset, we showed that the proposed method significantly outperformed conventional methods. The average Pearson correlation coefficient between the predicted and CT-derived ground truth metrics was increased from 0.460 to 0.863.
Introduction
As populations age, musculoskeletal conditions like sarcopenia (loss of muscle mass) and osteoporosis (loss of bone density) present significant public health challenges. While Computed Tomography (CT) and Dual-energy X-ray Absorptiometry (DXA) are the current clinical standards for body composition analysis, they are limited by cost, radiation exposure, and accessibility. DXA, while more accessible than CT, provides only a 2D total body composition, failing to distinguish between overlapping anatomical structures.
Plain X-rays are ubiquitous and low-cost but traditionally lack the depth information required for quantitative muscle analysis. MSKdeX addresses this by extracting 3D-like quantitative muscle data from a standard 2D X-ray. The core idea is to "un-stack" the anatomy, allowing for the estimation of individual muscle properties even when they are obscured by other tissues in a standard projection.
Methods: Musculoskeletal Decomposition
The MSKdeX framework utilizes a multi-channel quantitative image translation model based on a CycleGAN architecture with an HRNet backbone. The model is designed to decompose a single X-ray image into multiple 2D projections, termed Digitally Reconstructed Radiographs (DRRs), for individual muscles and bones.
The model predicts three distinct DRR types:
- Volume DRR (VDRR): Represents muscle volume.
- Mass DRR (MDRR): Represents lean muscle mass.
- Weighted Volume DRR (WVDRR): Maintains structural consistency by representing weighted attenuation.
A key innovation is the Object-Wise Intensity-Sum (OWIS) Loss. Recognizing that while muscles deform with posture, their total mass and volume remain constant, OWIS enforces that the sum of pixel intensities in the predicted 2D projections matches the ground-truth values derived from 3D CT. Additionally, the model leverages the rigidity of bones. By performing 2D-3D rigid registration between X-rays and CT scans, the researchers provide "anchored" pixel-wise supervision for bones, which stabilizes the training for the surrounding, non-rigid muscle tissues.
Experimental Results
The method was evaluated on a dataset of 539 patients (primarily hip arthroplasty cases) with paired pre-operative X-rays and 3D CT scans. Ground truth labels were generated via automated fine-grained segmentation of the CT scans.
MSKdeX demonstrated a substantial improvement over conventional deep-learning baselines. The average Pearson Correlation Coefficient (PCC) between predicted metrics and CT-derived ground truth increased from 0.460 to 0.863. For specific muscles like the gluteus medius, the PCC reached 0.877.
Beyond correlation, the Mean Absolute Error (MAE) for both muscle mass and volume was approximately halved compared to standard methods. Qualitative analysis confirmed that MSKdeX produces high-fidelity projections that closely match reference data, avoiding the "hallucinations" common in standard GAN-based translations.
Conclusion and Future Work
MSKdeX represents a significant step toward accessible, low-radiation musculoskeletal monitoring. By combining physics-inspired loss functions with anatomical decomposition, it achieves high-accuracy muscle quantification from standard X-rays.
Future work will focus on addressing the demographic bias in the current dataset, which primarily featured older female patients. Expanding the anatomical scope beyond the pelvic region and validating the model in broader clinical settings are essential steps toward making this a standard diagnostic tool for aging-related musculoskeletal diseases.
Reference: Gu, Y., Otake, Y., et al. "MSKdeX: Musculoskeletal (MSK) decomposition from an X-ray image for fine-grained estimation of lean muscle mass and muscle volume." arXiv:2305.19920v2, 2023.
Summary updated