NeurIPS 2026Coming to NeurIPS in Sydney?Explore papers, orals & directions

Manifold-Guided Stereo-Monocular Refinement for Endoscopic Stereo Disparity Estimation

Jiewen Yang, Yi Zhong, Bin Pu, Xingbo Dong, Ming Zheng, Qika Lin, Kai He, Xuechen ZhangNeurIPS 2026

TL;DR

Inside the human body, shiny wet tissue, smoke, and featureless surfaces constantly blind standard 3D stereo cameras used in robotic surgery. Manifold-Stereo solves this by treating monocular depth AI like a surgical co-pilot: it gently molds the AI’s scale-blind "intuition" to fit real stereo geometry, and then uses a spatial "trust gate" to let that intuition take over only in pixels where traditional stereo matching breaks down. The result is crisp, metrically accurate 3D surgical perception that knows when to trust physics and when to lean on context.

What Problem Does This Paper Address?

To navigate safely or overlay augmented reality during minimally invasive surgery, computers need dense 3D depth maps. This is usually done via stereo disparity estimation—measuring how many pixels a physical point shifts between a left and right camera view.

In natural outdoor scenes, stereo matching works wonders. Inside an illuminated surgical cavity, however, correspondence reliability is wildly uneven within the exact same frame. Textured tissue yields rock-solid metric depth, right next to glaring specular highlights, surgical smoke, or smooth, homogeneous organs where matching completely fails.

Recent methods bring in monocular depth priors (like foundation models that guess 3D shape from a single 2D image) to help fill in the blanks. The catch? Monocular models don't know true metric scale, and existing pipelines tend to blend stereo and monocular features globally or blindly. This creates a frustrating catch-22: rely too much on stereo, and you propagate garbage matches across shiny or textureless regions; rely too much on the monocular prior, and its uncalibrated guesses overwrite precise, trustworthy stereo measurements.

Figure 1: Motivation for reliability-aware stereo-monocular refinement. Stereo matching provides metric correspondence evidence where left-right alignment is reliable, while a locally refined monocular candidate can support regions with ambigu- ous correspondence.

Methods

Manifold-Stereo refuses to use fixed global weights. Instead, it builds a pipeline around two novel ideas: geometric-guided monocular correction and reliability-gated fusion.

Figure 2: Pipeline of Manifold-Stereo for endoscopic stereo disparity estimation. Given a rectified stereo pair, stereo and monocular disparity candidates are constructed from cost-volume geometry and monocular context. A conditional latent residual flow refines the monocular candidate in an image-aligned local correction space, and geometric consistency-gated recurrent refinement controls its contribution to calibrated stereo updates.
  1. Standard Candidate Construction: First, a CNN stereo branch builds a standard 3D cost volume (measuring left-right feature correlations across possible pixel shifts) to get an initial disparity map. Simultaneously, a frozen Vision Transformer (ViT) monocular branch looks at a single view to predict an uncalibrated, big-picture disparity candidate.
  2. Conditional Latent Residual Flow (What's New): Before letting the monocular candidate anywhere near the final output, it needs to respect the stereo camera's geometry. The authors compress the stereo cost volume into a 2D spatial latent space—an operational "manifold" anchored to stereo evidence. They then refine the monocular candidate by integrating a learned vector field over 8 Runge-Kutta (RK4) steps (acting like a Neural ODE, not generative diffusion). Regularizers keep this trajectory from wandering too far, producing a spatially smooth disparity offset that fixes local monocular distortions.
  3. Per-Pair Scale Calibration & Reliability Gating (What's New): Because the refined monocular map still lacks true scale, the model runs a quick least-squares fit (without ground truth) to align its scale and offset to the current stereo estimate. Finally, during iterative RAFT-style updates, a geometric consistency gate takes charge. It warps the right camera's features into the left view using the current stereo disparity. Where left and right features align cleanly, the gate trusts the stereo branch ($w_{\text{stereo}} \approx 1$). Where alignment fails—like on a blinding reflection—the gate smoothly dials up the calibrated monocular candidate ($w_{\text{mono}} = 1 - w_{\text{stereo}}$).

Datasets

No new datasets are introduced; the authors train and evaluate on three established endoscopic benchmarks:

  • SCARED: Rectified stereo images of porcine cadavers captured via a da Vinci Xi surgical robot with structured-light 3D ground truth. Used for training, validation, and in-domain testing.
  • SERV-CT: 16 stereo pairs of porcine torsos with CT-derived ground truth, used strictly for zero-shot cross-domain testing.
  • Hamlyn: 22 challenging real-world surgical videos featuring dynamic tissue deformation, surgical tools, and smoke occlusion, also used for zero-shot evaluation.

Key Insights and Ideas

  • Don't just add a head—walk the path: In ablations, evaluating the latent vector field in a single step increased pixel error (EPE) from 3.05 px to 3.55 px, and removing path-energy regularization spiked it to 3.84 px. Smoothly stepping through the cost-volume-anchored space is what stops monocular corrections from hallucinating.
  • Dynamic gating beats uniform mixing: Replacing the left-right consistency gate with fixed, uniform mixing degraded accuracy noticeably. Similarly, skipping the simple least-squares scale alignment caused errors to balloon (EPE jumped from 3.05 px to 4.32 px), proving that monocular context is toxic to stereo updates unless metrically calibrated first.
  • Suppressing catastrophic outliers: On zero-shot video transfers, Manifold-Stereo occasionally trails slightly on ultra-tight 1-pixel error thresholds (Bad1), yet wins on average error (EPE) and larger outlier metrics (Bad3). Why? Because the gate selectively steps in to crush massive, wild correspondence failures in shiny or occluded zones while leaving good pixels alone.

Key Results

Manifold-Stereo achieves state-of-the-art average disparity accuracy in-domain and transfers remarkably well zero-shot without any fine-tuning:

  • SCARED (In-Domain): Achieves the best performance across all aggregate metrics, hitting 2.53 mm mean Depth MAE and 3.05 px End-Point Error (EPE)—improving over StereoMamba (3.39 px)—while claiming the lowest D1 outlier rate at 24.33%.
  • SERV-CT (Zero-Shot): Sweeps every single metric by a wide margin, slashing EPE from StereoMamba's 2.63 px down to 1.70 px, and dropping D1 outliers from 14.86% to 8.96%.
Table 2: Zero-shot SERV-CT results. Dynamic- Stereo requires sequences and is inapplicable to these static pairs.
  • Hamlyn (Zero-Shot): Takes first place in EPE (4.24 px) and Bad3 (27.96%), and ranks a close second in D1 (27.49%) behind RRESM, producing visually continuous organ surfaces without mottled border artifacts.

Limitations and Future Work

  • Frame-by-frame amnesia: Manifold-Stereo processes each stereo pair independently. In real surgical videos, ignoring temporal continuity leaves free performance on the table.
  • Total blackout scenarios: If a region is so severely degraded (e.g., thick smoke or extreme tool occlusion) that both stereo matching and monocular priors fail, the gate cannot magically invent geometry—garbage in still equals garbage out.
  • Future Directions: The authors plan to extend their latent-flow refinement into the spatio-temporal domain to handle dynamic, deforming endoscopic video sequences seamlessly.

Summary updated

Abstract

Dense stereo disparity estimation provides the geometric basis for 3D perception in computer-assisted endoscopy. Endoscopic stereo matching is difficult because reliable tissue correspondences often appear next to weak-texture, specular, occluded, or deformed regions within the same frame. Existing stereo and stereo-monocular methods improve cost aggregation or introduce monocular priors, but they often treat monocular guidance as a global feature source or an independently predicted candidate. Without evaluating the local support of the current stereo match during refinement, the update can reinforce corrupted correspondences in ambiguous regions or allow monocular priors to override reliable metric matches. To tackle these problems, we introduce Manifold-Stereo, a reliability-gated latent-flow framework for endoscopic stereo disparity estimation. The method refines a monocular disparity candidate through a conditional latent residual flow on an image-aligned correction space induced by stereo cost-volume geometry, then calibrates the corrected candidate to the current stereo disparity scale. A geometric consistency gate computed from left-right feature alignment regulates the candidate contribution during recurrent refinement, preserving stereo estimates in well-matched regions while supplying monocular context where local matching is ambiguous. Experiments on in-domain SCARED and zero-shot SERV-CT and Hamlyn show strong average disparity accuracy and competitive thresholded outlier rates against recent stereo and endoscopic baselines.
BibTeX
@inproceedings{yang2026manifold,
  author = {Jiewen Yang and Yi Zhong and Bin Pu and Xingbo Dong and Ming Zheng and Qika Lin and Kai He and Xuechen Zhang},
  title = {{Manifold-Guided Stereo-Monocular Refinement for Endoscopic Stereo Disparity Estimation}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=iGyOrOrioU},
}
Figure