Abstract
Robotic-assisted surgery allows surgeons to conduct precise surgical operations with stereo vision and flexible motor control. However, the lack of 3D spatial perception limits situational awareness during procedures and hinders mastering surgical skills in the narrow abdominal space. Depth estimation, as a representative perception task, is typically defined as an image reconstruction problem. In this work, we show that depth estimation can be reformed from a 3D surface perspective. We propose a loss function for depth estimation that integrates the surface-aware constraints, leading to a faster and better convergence with the valid information from spatial information. In addition, camera parameters are incorporated into the training pipeline to increase the control and transparency of the depth estimation. We also integrate a specularity removal module to recover more buried image information. Quantitative experimental results on endoscopic datasets and user studies with medical professionals demonstrate the effectiveness of our method.
Introduction
In robotic-assisted surgery, surgeons rely on stereo vision to navigate the narrow, complex environment of the human abdomen. However, human eyes are prone to depth perception errors, and automated systems struggle with the unique "hostile" environment of the body. Endoscopic images are notoriously difficult for AI to process due to textureless surfaces, specular highlights, and a prevalent 2D bias in existing models that ignore underlying 3D physical structures.
Methods
The proposed modular pipeline treats depth estimation as a 3D surface recovery problem rather than a simple pixel-matching task.
Specularity Removal
Before depth estimation, a dedicated neural network module identifies and "cleans" specular reflections. This recovers underlying tissue texture previously hidden by glare, facilitating better feature extraction.
Oriented Point (OP) Loss
The core innovation is the Oriented Point (OP) Loss. Instead of just comparing predicted depth values to ground truth in 2D, the model uses camera parameters to "back-project" pixels into 3D space. The OP loss consists of two primary components:
- Point Distance Loss ($L_{p2p}$): Ensures the 3D coordinates of the predicted surface match the ground truth.
- Normal Similarity Loss ($L_{n2n}$): Ensures the orientation (surface normal) of the predicted surface is correct, respecting local smoothness and curvature.
Backbone Architecture
The system utilizes a lightweight Stereo-Transformer (STTR) as the base model, demonstrating that the OP loss can significantly boost the performance of existing architectures.
Experimental Results
The study utilized the SCARED and Hamlyn datasets for evaluation. Quantitative improvements were dramatic, particularly on the SCARED dataset.
As shown in the results table, the baseline STTR model had a Mean Average Error (MAE) of 68.95mm on the SCARED dataset. By incorporating the OP Loss, the error plummeted to 20.33mm—a nearly 70% improvement. The Root Mean Square Error (RMSE) also dropped significantly (from 69.38mm to 25.92mm), indicating higher consistency and fewer outliers.
A user study with 10 experienced surgeons further validated these findings. Surgeons rated the OP Loss-generated depth maps higher for spatial perception and point cloud quality, noting that the results were closer to the actual surgical ground truth.
Conclusion
By shifting the focus from 2D image reconstruction to 3D surface geometry, this research provides a more robust framework for endoscopic depth estimation. Incorporating camera parameters and surface normals allows the model to learn physical constraints, leading to smoother and more accurate reconstructions. Future work will explore end-to-end integration of the specularity removal module and the incorporation of more complex geometric features like isocontours.
Summary updated