Make-A-Volume: Leveraging Latent Diffusion Models for Cross-Modality 3D Brain MRI Synthesis

Lingting Zhu, Zeyue Xue, Zhenchao Jin, Xian Liu, Jingzhen He, Ziwei Liu, Lequan Yu

Abstract

Cross-modality synthesis in medical imaging is a critical task for clinical diagnostics, particularly when specific scans are unavailable due to time constraints, patient contraindications, or hardware limitations. However, existing synthesis methods often suffer from a "dimensionality dilemma": 2D models lack volumetric consistency, while 3D models are computationally prohibitive. This paper introduces Make-A-Volume, a novel two-stage diffusion framework designed to synthesize high-fidelity 3D medical images. By combining the efficiency of 2D Latent Diffusion Models (LDMs) with specialized volumetric layers, Make-A-Volume achieves superior 3D consistency and image quality compared to traditional GAN-based or purely 2D approaches.

Introduction

In clinical practice, obtaining a comprehensive suite of medical imaging—such as both T1-weighted and T2-weighted MRI scans—is often impractical. Cross-modality synthesis offers a solution by using one available scan to predict the appearance of another. Despite its potential, current methods face significant hurdles. 2D-based models, while computationally efficient, process slices independently, leading to "jittery" or inconsistent structures when reconstructed into a 3D volume. Conversely, full 3D models attempt to capture volumetric context but require massive GPU memory and are notoriously difficult to train, often leading to instability or mode collapse in GAN-based architectures.

The Make-A-Volume Framework

Make-A-Volume addresses these challenges through a two-stage approach that bridges the gap between 2D efficiency and 3D coherence.

Stage 1: Slice-wise Latent Diffusion

To manage the high computational cost of diffusion models, Make-A-Volume operates in a compressed latent space. The model utilizes a pretrained autoencoder to map high-resolution raw pixels into a lower-dimensional representation. A diffusion model is then trained to perform cross-modality translation within this latent space. This strategy significantly reduces memory requirements while preserving the intricate details necessary for medical diagnostics.

Stage 2: Volumetric Integration

To resolve the inter-slice inconsistency common in 2D approaches, the researchers introduced specialized volumetric layers into the 2D U-Net architecture. These layers, consisting of 1D convolutions, are designed to capture dependencies across the z-axis (the depth of the volume).

A critical innovation in this stage is the use of Timestep Consistency. During the fine-tuning of these volumetric layers, the diffusion timestep ($t$) is kept identical for every slice within a single volume. This ensures that the model treats the stack of slices as a unified object, encouraging the network to learn the structural relationships between neighboring slices rather than treating them as isolated images.

Experimental Evaluation

The framework was evaluated on two distinct brain MRI tasks:

  1. SWI-to-MRA (S2M): An in-house dataset of 111 patients featuring complex blood vessel structures. This dataset serves as a rigorous test for volumetric consistency, as any misalignment between slices becomes immediately apparent in the vascular rendering.
  2. RIRE (Retrospective Image Registration Evaluation): A public benchmark dataset for T1-to-T2 weighted MRI synthesis, providing a standard for cross-modality performance.

Results and Discussion

Make-A-Volume demonstrated significant improvements over several baselines, including Pix2pix (2D and 3D), Palette (a 2D diffusion model), and CycleGAN 3D.

Quantitative Performance

On the challenging S2M dataset, Make-A-Volume achieved a Mean Absolute Error (MAE) of 4.801, a substantial improvement over Pix2pix 3D (6.234) and the 2D Palette model (26.806). The model also outperformed competitors in Structural Similarity (SSIM) and Peak Signal-to-Noise Ratio (PSNR), indicating higher fidelity to the ground truth.

Qualitative Consistency

Visually, Make-A-Volume eliminates the "staircase" artifacts typically seen in 2D synthesis methods when viewed from the coronal or sagittal planes. The synthetic volumes produced by the framework exhibit smooth, continuous anatomical structures. This is particularly evident in the fine branching of blood vessels in MRA scans, which remain coherent across the entire 3D stack.

Conclusion and Future Work

Make-A-Volume represents a significant step forward in making 3D-aware diffusion models computationally feasible for medical imaging. By leveraging latent space and pseudo-3D convolutional layers, the framework provides a scalable solution for high-quality cross-modality synthesis.

Future research will focus on increasing the resolution of the synthesized volumes beyond the current 256x256 standard and improving inference speeds. While diffusion models offer superior stability and quality compared to GANs, their iterative nature remains a bottleneck for real-time clinical applications. Investigating accelerated sampling methods for volumetric data will be a priority for future iterations of the framework.

Summary updated

BibTeX
@inproceedings{zhu2023make,
  author = {Lingting Zhu and Zeyue Xue and Zhenchao Jin and Xian Liu and Jingzhen He and Ziwei Liu and Lequan Yu},
  title = {{Make-A-Volume: Leveraging Latent Diffusion Models for Cross-Modality 3D Brain MRI Synthesis}},
  booktitle = {International Conference on Medical Image Computing and Computer-Assisted Intervention},
  year = {2023},
  doi = {10.1007/978-3-031-43999-5\_56},
}
Figure