Influence of Motion Restrictions in an Ankle Exoskeleton on Gait Kinematics and Stability in Straight Walking

Miha Dezman, Charlotte Marquardt, Adnan Ugur, Tamim Asfour

TL;DR

Ankle exoskeletons often simplify joint mechanics to reduce weight, but these kinematic restrictions can significantly disrupt natural gait. This study demonstrates that increasing an ankle exoskeleton's degrees of freedom (DoF) from one to three improves gait kinematics and stability, with the most substantial benefits occurring when transitioning from a single-axis (sagittal plane only) to a dual-axis design.

What Problem Does This Paper Address?

The human ankle is a complex joint with three degrees of freedom: plantar-/dorsiflexion (up/down), in-/eversion (side-to-side), and internal/external rotation (twisting). While most exoskeleton designs focus solely on the sagittal plane (up/down) to minimize mechanical complexity and weight, this simplification imposes rigid constraints on the user.

Existing research has extensively covered how the weight of an exoskeleton affects metabolic cost and gait, but there is less clarity on how kinematic restrictions—the physical blocking of natural joint rotations—impact a user's stability and walking patterns. The authors seek to quantify these effects to inform better trade-offs between mechanical simplicity and biological compatibility.

Methods

The researchers conducted a pilot study with six healthy participants using a custom-designed, rigid-frame ankle exoskeleton. The key innovation was the device's modularity: by adding or removing specific fixture elements (blocking parts), the researchers could toggle the device between three configurations:

  • Exo1DoF: Only allows plantar-/dorsiflexion.
  • Exo2DoF: Adds in-/eversion.
  • Exo3DoF: Adds internal/external rotation.
The three exoskeleton configurations: Exo3DoF, Exo2DoF, and Exo1DoF. The kinematic structure comprises various joint types.

Participants walked a 3-meter path under four conditions: without the exoskeleton (NoExo) and in each of the three ExoXDoF configurations. Data was collected using an optical motion capture (MOCAP) system and heel switches to segment the gait into individual strides. The team analyzed gait parameters (stride length, time, and width), joint kinematics (RMSE similarity to natural walking), and stability (calculated via trunk acceleration stabilograms).

Key Insights and Ideas

  • The Diminishing Returns of DoF: The transition from 1 DoF to 2 DoF yielded a much larger improvement in gait metrics than the transition from 2 DoF to 3 DoF. This suggests that for straight-line walking, accommodating in-/eversion is a critical "minimum requirement" for kinematic compatibility.
  • Soft Tissue Compliance: Even when the exoskeleton was mechanically locked in the internal/external rotation axis (Exo1DoF and Exo2DoF), the user's leg still exhibited some rotation. The authors measured this as "cuff rotation"—the leg twisting inside the device's shank cuff. As more DoFs were unlocked, this relative sliding decreased, indicating the device was better following the body's natural motion.
  • The Stability Paradox: Wearing the exoskeleton generally reduced the magnitude of trunk accelerations compared to natural walking. While lower acceleration might sound "stable," the authors interpret this as users adopting a "cautious walking style" to compensate for the device. Adding DoFs moved these stability values back toward the natural (NoExo) baseline.

Key Results

  • Kinematic Similarity: The Exo3DoF configuration was the most similar to natural walking across all three axes. For the primary walking motion (PF/DF), the RMSE dropped from 2.63° in the 1 DoF case to 2.33° in the 3 DoF case.
  • Gait Parameters: Stride time increased when wearing the exoskeleton but showed slight improvements (moving closer to NoExo) as DoFs were added. Stride width also increased with more DoFs, suggesting a more natural base of support.
  • Range of Motion (RoM): The most dramatic improvement was seen in internal/external rotation RoM, which was nearly restored to natural levels in the 3 DoF configuration.
RoM for all three ankle rotations during straight walking for all configurations.

Limitations and Future Work

The authors identify several hardware-related hurdles:

  • Weight and Inertia: At 1.8 kg, the exoskeleton is heavy enough to negatively impact gait regardless of the DoF settings.
  • Rigid Sole: The device uses a rigid sole, which causes noticeable phase delays in the gait cycle compared to natural walking.
  • Short Walking Path: The 3-meter path may have prevented users from reaching a truly stable, steady-state gait.

Future Work: The team is already developing a second iteration of the device. This new version will feature a lighter frame, a flexible sole to improve roll-over characteristics, and an extension to include a knee joint, which they expect will make the 3rd DoF (rotation) even more critical for user comfort and performance.

Summary updated

Abstract

Exoskeleton devices impose kinematic constraints on a user's motion and affect their stability due to added mass but also due to the simplified mechanical design. This paper investigates how these constraints resulting from simplified mechanical designs impact the gait kinematics and stability of users by wearing an ankle exoskeleton with changeable degree of freedom (DoF). The exoskeleton used in this paper allows one, two, or three DoF at the ankle, simulating different levels of mechanical complexity. This effect was evaluated in a pilot study consisting of six participants walking on a straight path. The results show that increasing the exoskeleton DoF results in an improvement of several metrics, including kinematics and gait parameters. The transition from 1 DoF to 2 DoF is shown to have a larger effect than the transition from 2 DoF to 3 DoF for an ankle exoskeleton. However, an exoskeleton with 3 DoF at the ankle featured the best results. Increasing the number of DoF resulted in stability values closer the values when walking without the exoskeleton, despite the added weight of the exoskeleton.
BibTeX
@misc{dezman2024influence,
  author = {Miha Dezman and Charlotte Marquardt and Adnan Ugur and Tamim Asfour},
  title = {{Influence of Motion Restrictions in an Ankle Exoskeleton on Gait Kinematics and Stability in Straight Walking}},
  year = {2024},
  eprint = {2406.06054},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2406.06054},
}
Figure