Influence of Motion Restrictions in an Ankle Exoskeleton on Gait Kinematics and Stability in Straight Walking

Miha Dežman, Charlotte Marquardt, Tobias Moeller, Tamim Asfour

TL;DR

This study investigates how limiting the ankle's movement with an exoskeleton affects walking. By testing exoskeletons with one, two, or three degrees of freedom (DoF), researchers found that more freedom generally leads to better walking kinematics and stability, with the three-DoF version performing best. This suggests that while exoskeletons can aid movement, their design's kinematic compatibility is crucial for natural gait.

What Problem Does This Paper Address?

Ankle exoskeletons are designed to assist with walking, but they can also impose kinematic constraints on the user's natural movement. These constraints, along with the added weight and inertia of the device, can negatively impact gait and stability. While previous research has focused on the effects of weight and inertia, this paper specifically addresses the impact of kinematic restrictions imposed by the exoskeleton's design. The authors aim to understand how varying the degrees of freedom (DoF) in an ankle exoskeleton influences a user's gait kinematics, stability, and how these changes compare to walking without any assistive device. This is important because ankle exoskeletons need to balance providing assistance with maintaining natural and stable movement for everyday activities.

Methods

The core of this study involved a custom-designed ankle exoskeleton that could be configured to allow one, two, or three degrees of freedom (DoF) for the ankle joint. The three configurations were:

  • Exo1DoF: Restricted to only plantarflexion/dorsiflexion (PF/DF).
  • Exo2DoF: Allowed PF/DF and inversion/eversion (IN/EV).
  • Exo3DoF: Allowed PF/DF, IN/EV, and internal/external rotation (IR/ER), mimicking the natural ankle movement.

These restrictions were implemented by immobilizing specific joints of the exoskeleton using fixture elements. The researchers conducted a user study with six healthy participants who walked on a straight path under four conditions:

  1. NoExo: Walking without any exoskeleton (baseline).
  2. Exo1DoF: Wearing the 1-DoF exoskeleton on the right leg.
  3. Exo2DoF: Wearing the 2-DoF exoskeleton on the right leg.
  4. Exo3DoF: Wearing the 3-DoF exoskeleton on the right leg.

To account for the exoskeleton's weight and sole thickness, participants also wore a foot frame on their left leg. Motion capture data was collected using an optical system to analyze gait kinematics and stability. Key metrics included:

  • Kinematics: Range of Motion (RoM) and Root Mean Squared Error (RMSE) for PF/DF, IN/EV, and IR/ER ankle rotations. Cuff rotation was also measured to assess the influence of soft tissue compliance.
  • Gait Parameters: Stride length, stride width, stride time, and foot height.
  • Stability: Trunk roll and pitch accelerations, analyzed using stabilograms and instability RMS values.

Datasets

Not discussed in the paper. The study utilized data collected from a user study with six participants.

Key Insights and Ideas

  • More DoF, Better Gait: The study strongly suggests that increasing the degrees of freedom in an ankle exoskeleton generally leads to improved gait kinematics and stability, bringing them closer to natural walking patterns.
  • The 1-to-2 DoF Transition is Key: The transition from a 1-DoF to a 2-DoF exoskeleton showed a more significant improvement in gait metrics than the transition from 2-DoF to 3-DoF. This highlights the importance of enabling at least inversion/eversion alongside plantar/dorsiflexion.
  • 3-DoF is Optimal (for this study): While the 1-to-2 DoF jump was substantial, the 3-DoF configuration ultimately yielded the best results, most closely resembling the baseline (NoExo) condition in terms of stability and kinematics.
  • Stability Benefits from More DoF: Wearing the exoskeleton, even with restrictions, generally reduced trunk accelerations compared to the NoExo condition. However, the 3-DoF configuration provided the highest instability values (closest to baseline), indicating better dynamic stability.
  • IR/ER Restrictions are Less Critical for Straight Walking: Restricting internal/external rotation (IR/ER) had a less pronounced effect on straight-line walking compared to restricting inversion/eversion. This is likely due to the compliance of soft tissues around the ankle allowing for some IR/ER movement even when mechanically restricted.
  • Weight vs. Kinematics Trade-off: While the exoskeleton's weight (1.8 kg) is acknowledged as a limitation, the study's findings suggest that kinematic compatibility (DoF) plays a significant role in mitigating negative effects, even with added mass.

Key Results

  • Kinematics: The 3-DoF exoskeleton showed the highest similarity (lowest RMSE) to the NoExo condition for PF/DF and IR/ER. For IN/EV, the 3-DoF also performed best, though the 1-DoF was also quite similar. RoM for PF/DF and IR/ER improved with increasing DoF, with the 3-DoF configuration closely matching the NoExo RoM.
  • Gait Parameters: Stride time increased slightly with the exoskeleton, but improved towards the NoExo condition with more DoF. Stride length decreased for the exoskeleton leg, but was less affected by DoF changes. Stride width increased with more DoF, and its standard deviation decreased. Foot height remained largely consistent across conditions, with some fluctuation in the left foot.
  • Stability: Wearing the exoskeleton (all DoF configurations) generally reduced trunk accelerations. The 3-DoF configuration resulted in the smallest Gaussian ellipsoids for trunk accelerations, indicating reduced instability and higher similarity to the NoExo condition. Instability RMS values increased with DoF, with the 3-DoF condition showing the highest instability (closest to baseline).

Limitations and Future Work

  • Exoskeleton Weight: The 1.8 kg weight of the exoskeleton is a significant limitation that negatively impacts gait. The authors note that previous studies have shown weight to increase stride length and time and decrease step height, though their results showed longer stride times and shorter stride lengths.
  • Short Walking Path: The study used a short walking path, which may have prevented participants from fully adapting to the exoskeleton and achieving a stable gait. A longer path would allow for more natural adaptation.
  • Rigid Sole: The rigid sole of the exoskeleton is identified as another hardware limitation that can cause short phase delays in gait curves.
  • Participant Variability: While the exoskeleton reduced variability between participants, the NoExo condition showed higher variability in stability measures.
  • Future Work: The authors plan to develop a second iteration of the exoskeleton with a lighter frame, a flexible sole, and a knee joint extension. This will allow for further investigation into the findings of this study and explore the combined effects of ankle and knee exoskeletons. They also suggest that IR/ER becomes more relevant when an ankle exoskeleton is combined with a knee joint.

Summary updated

Abstract

Exoskeleton devices may impose kinematic constraints on a user’s motion and affect their stability due to added mass and inertia, but also due to the simplified mechanical design. This study explores the impact of kinematic constraints imposed by exoskeletons on user gait, stability, and perceived discomfort. Specifically, it examines how the varying degrees of freedom (DoF) in an ankle exoskeleton influence these factors. The exoskeleton utilized in this study can be configured to allow one, two, or three DoF, thereby simulating different levels of mechanical complexity and kinematic compatibility. A pilot study was conducted with six participants walking on a straight path to evaluate these effects. The findings indicate that increasing DoF of the exoskeleton improves several criteria, including kinematics and stability. In particular, the transition from 1 DoF to 2 DoF yielded a larger improvement than the transition from 2 DoF to 3 DoF, although the 3 DoF configuration produced the best overall results. Higher DoF configurations also resulted in stability values that resemble more closely those of walking without the exoskeleton, despite the added weight. Subjective feedback from participants corroborated these results, indicating the lowest discomfort with the 3 DoF ankle exoskeleton.
BibTeX
@misc{dezman2024influence,
  author = {Miha Dežman and Charlotte Marquardt and Tobias Moeller and Tamim Asfour and Tamim Asfour},
  title = {{Influence of Motion Restrictions in an Ankle Exoskeleton on Gait Kinematics and Stability in Straight Walking}},
  year = {2024},
  eprint = {2406.06054},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2406.06054},
}
Figure