NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Improving segmentation of calcified and non-calcified plaques on CCTA-CPR scans via masking of the artery wall

Antonio Tejero-de-Pablos, Hiroaki Yamane, Yusuke Kurose, Junichi Iho, Youji Tokunaga, Makoto Horie, Keisuke Nishizawa, Yusaku Hayashi, Yasushi Koyama, Tatsuya Harada · DOI

TL;DR

This paper introduces a spatial masking strategy to significantly improve the automated detection of coronary artery plaques in CT scans. By restricting the search space of a deep learning model to just the artery wall, the researchers effectively filtered out background noise and ambiguous tissue intensities, leading to a dramatic performance boost—especially for dangerous, hard-to-detect non-calcified plaques.

What Problem Does This Paper Address?

Coronary artery disease is a leading cause of death, often driven by the buildup of plaques that narrow the arteries. Clinicians use Coronary Computed Tomography Angiography (CCTA) to identify these plaques. While "calcified" plaques (hardened by calcium) are bright and easy to spot, "non-calcified" plaques are much more dangerous because they are unstable and prone to rupture.

Unfortunately, non-calcified plaques are notoriously difficult for AI to segment. Their voxel intensities in CT scans often overlap with surrounding fat, background tissues, and imaging artifacts. Standard deep learning models frequently get "confused" by this noise, leading to missed detections or inaccurate shapes. The authors hypothesize that by providing the model with the anatomical context of the artery wall, they can eliminate these confounding factors.

Methods

The authors propose a two-step pipeline for plaque segmentation:

  1. Artery Wall Masking: The system first identifies the inner and outer surfaces of the artery wall. This creates a binary mask that isolates the wall itself. The researchers tested several mask types: perfect ground-truth masks, masks with added synthetic noise (small and large), and masks generated by a state-of-the-art automated detector called HybridResUNet.
  2. Plaque Segmentation: The input CCTA volume is multiplied by this mask, effectively "blacking out" everything except the artery wall. This masked volume is then fed into a second HybridResUNet model.
Figure 1. Overview of our methodology. The artery wall is extracted prior to segmentation and used to create a mask. The mask removes voxels with ambiguous intensities facilitating the segmentation.

The task is modeled as a 4-class segmentation problem: background/lumen, artery wall, calcified plaque, and non-calcified plaque. To handle the fact that plaques are much rarer than healthy tissue, the authors used a weighted Dice loss, where less common classes are given higher importance during training.

Datasets

The study utilized a non-public dataset consisting of:

  • 100 CCTA scans, yielding 291 individual coronary arteries (LAD, LCX, and RCA).
  • 102,983 total slices (cross-sections).
  • Expert Annotations: Each voxel was labeled by three expert radiologists into one of five categories (background, lumen, artery wall, calcified plaque, or non-calcified plaque).

The data was processed using Curved Planar Reformation (CPR), which "straightens" the coronary arteries to make them easier to analyze.

Key Insights and Ideas

  • Spatial Context Overcomes Intensity Ambiguity: The most important takeaway is that knowing where to look is just as important as what the pixels look like. By removing the "distraction" of surrounding fat and nearby vessels, the model can focus on the subtle intensity differences that signal a non-calcified plaque.
  • Robustness to Noise: Interestingly, even when the artery wall mask was imperfect (containing synthetic noise or generated by an automated tool), the plaque segmentation performance remained significantly higher than using no mask at all.
  • Clinical Validation: Radiologists confirmed that the masked methodology was able to identify real plaques that were actually missing from the original manual annotations, suggesting the model might even assist experts in finding subtle lesions.

Key Results

The quantitative results, measured by the Dice score (a metric for overlap between predicted and ground-truth shapes), show a clear advantage for masking:

Table 1. Class-wise Dice score comparison of different masking configurations in our methodology. The ground-truth wall configuration does not use a background class.
  • Non-calcified Plaques: The Dice score jumped from 0.49 (no mask) to 0.73 (ground-truth mask). Even with an automated wall detector (HybridResUNet), the score was 0.58, outperforming the unmasked baseline.
  • Calcified Plaques: Performance improved from 0.73 (no mask) to 0.83 (ground-truth mask).
  • Qualitative Improvement: As seen in Figure 2, the masked models produced much cleaner plaque shapes that stayed strictly within the artery wall, whereas the unmasked model (e) often produced "leaky" segmentations that protruded into the surrounding tissue.
Figure 2. Sample results for different mask configurations: (a) GT mask, (b) GT mask + small noise, (c) GT mask + large noise, (d) Wall segmentation (HybridResUNet), (e) No mask. The upper row shows the ground-truth (GT).

Limitations and Future Work

The primary limitation is the dependency on the quality of the initial artery wall detection. If the mask is significantly off-center or inaccurate, it can lead to false positives (e.g., mistaking lumen voxels for calcified plaque).

The authors suggest that the next logical step is to train both the wall detection and plaque segmentation models together in an end-to-end fashion. This would allow the two tasks to inform each other, potentially leading to even higher accuracy and more robust clinical tools.

Summary updated

BibTeX
@inproceedings{tejerodepablos2023improving,
  author = {Antonio Tejero-de-Pablos and Hiroaki Yamane and Yusuke Kurose and Junichi Iho and Youji Tokunaga and Makoto Horie and Keisuke Nishizawa and Yusaku Hayashi and Yasushi Koyama and Tatsuya Harada},
  title = {{Improving segmentation of calcified and non-calcified plaques on CCTA-CPR scans via masking of the artery wall}},
  booktitle = {Medical Imaging: Computer-Aided Diagnosis},
  year = {2023},
  url = {https://openreview.net/forum?id=pFC3VT7cYf},
}
Figure