Improving segmentation of calcified and non-calcified plaques on CCTA-CPR scans via masking of the artery wall

Antonio Tejero-de-Pablos, Hiroaki Yamane, Yusuke Kurose, Junichi Iho, Youji Tokunaga, Makoto Horie, Keisuke Nishizawa, Yusaku Hayashi, Yasushi Koyama, Tatsuya Harada

TL;DR

This paper introduces a novel method to improve the segmentation of coronary artery plaques (both calcified and non-calcified) in CCTA scans by masking out irrelevant parts of the artery wall. This "masking" approach significantly boosts segmentation accuracy, especially for challenging non-calcified plaques, by focusing the analysis on the critical artery wall region.

What Problem Does This Paper Address?

Coronary artery disease, often diagnosed through CCTA scans, is a major health concern. Detecting plaques within the arteries is crucial, but distinguishing between calcified and non-calcified plaques can be difficult. Non-calcified plaques are particularly problematic because their intensity values can be similar to surrounding tissues (like fat or background noise), making them hard to segment accurately. Existing deep learning methods, while powerful, still struggle with this ambiguity, leading to missed detections and imprecise plaque shapes, which hinders accurate vulnerability assessment. The core challenge is to reliably isolate and segment these plaques, especially the less stable non-calcified ones, by overcoming the noise and intensity ambiguities present in CCTA scans.

Methods

The proposed methodology centers on a two-step process. First, an "artery wall mask" is generated. This mask effectively isolates the voxels belonging to the artery wall, excluding background, lumen, and other surrounding tissues. The authors explore different levels of mask accuracy, from ground truth to imperfect masks generated by a state-of-the-art artery wall segmentation method (HybridResUNet) and even masks with added noise. Second, this generated mask is used to preprocess the input CCTA-CPR (Curved Planar Reformation) volumes before feeding them into a plaque segmentation network. The plaque segmentation network itself is an adaptation of HybridResUNet, modified with a weighted Dice loss function that prioritizes less common classes (like non-calcified plaques) and uses four output channels (background, artery wall, calcified plaque, non-calcified plaque) when imperfect masks are used.

Datasets

The study utilizes a private, non-public dataset of 100 CCTA scans. CPR volumes were extracted for the LAD, LCX, and RCA coronary arteries. Each voxel in the dataset was annotated by three expert radiologists into one of five classes: background, lumen, artery wall, calcified plaque, and non-calcified plaque. A subset of 25 scans was randomly selected for testing, ensuring an even distribution of plaques.

Key Insights and Ideas

  • Masking is Key: The central hypothesis, that masking irrelevant voxels (i.e., focusing on the artery wall) significantly improves plaque segmentation, is strongly supported. This is particularly true for challenging non-calcified plaques.
  • Artery Wall as a Boundary: By explicitly defining the artery wall region, the method effectively ignores ambiguous voxels from surrounding fat or lumen, reducing false positives and improving the precision of plaque detection.
  • Mask Accuracy Matters: While even imperfect artery wall masks provide a substantial improvement over no masking, the accuracy of the mask directly correlates with the quality of the plaque segmentation. Highly accurate masks lead to the best results.
  • Non-Calcified Plaque Challenge: The paper highlights the persistent difficulty in segmenting non-calcified plaques due to their intensity similarity with surrounding tissues, and demonstrates how the masking approach helps overcome this.

Key Results

  • Quantitative Improvement: Table 1 shows significant improvements in Dice scores across all plaque classes when using masked inputs compared to the unmasked approach (configuration (e)). For instance, the Dice score for non-calcified plaques increases from 0.49 (no mask) to 0.73 (GT mask). Even the less accurate HybridResUNet mask (d) outperforms the unmasked case.
  • Qualitative Success: Figure 2 visually demonstrates the effectiveness of the masking approach. The outputs with masked inputs (a, b, c, d) show more accurate plaque shapes and better containment within the artery wall compared to the unmasked output (e), which exhibits incomplete artery walls and plaques protruding outwards.
  • Handling Noise: The method shows robustness even with noisy masks, with configuration (c) (GT mask + large noise) still producing a shape closer to the ground truth than the unmasked case.

Limitations and Future Work

  • Mask Accuracy Dependency: The paper acknowledges that highly inaccurate artery wall masks can lead to false positive plaques, necessitating post-processing.
  • End-to-End Training: The authors suggest that training the artery wall segmentation and plaque segmentation networks together in an end-to-end manner could further improve performance for both tasks. This integrated approach is identified as a direction for future work.
  • Dataset Specificity: The study uses a private dataset, and further validation on larger, publicly available datasets would be beneficial.
  • Post-processing: While the paper mentions post-processing for false positives from inaccurate masks, details on specific post-processing techniques are deferred to a future manuscript.

Summary updated

BibTeX
@inproceedings{tejerodepablos2023improving,
  author = {Antonio Tejero-de-Pablos and Hiroaki Yamane and Yusuke Kurose and Junichi Iho and Youji Tokunaga and Makoto Horie and Keisuke Nishizawa and Yusaku Hayashi and Yasushi Koyama and Tatsuya Harada},
  title = {{Improving segmentation of calcified and non-calcified plaques on CCTA-CPR scans via masking of the artery wall}},
  booktitle = {Medical Imaging: Computer-Aided Diagnosis},
  year = {2023},
  url = {https://openreview.net/forum?id=pFC3VT7cYf},
}
Figure