Abstract
With the expansion of floating photovoltaics (FPV), rigid connectors offer advantages over polyester ropes by reducing the relative motion of floats and simplifying the layout of the connection system. However, the overall stability and safety of the floating photovoltaic system may be compromised if a wave crest occurs at the connection point of the rigid connector during motion. Furthermore, the rigid connectors with different degrees of freedom significantly impact the motion of the floats and their connection loads. In this study, three types of single-rod rigid connector models with varying constraints are established through numerical simulation to explore the feasibility of applying single-rod rigid connectors with different degrees of freedom in photovoltaic systems. Based on their degrees of freedom, these connectors are classified as cardan, purely rigid, and hinged. An analysis of float motion and connector loads in two-floating, four-floating, and eight-floating systems shows that as the number of floats increases, the axial distance between them decreases, resulting in more intense motion. Despite this, the eight-floating system maintains a certain safety distance. The maximum load on the connectors occurs in the middle of the multi-floating system, and releasing degrees of freedom can help mitigate some of the load effects.
Introduction: The Shift to Rigid Connectors
As the global energy transition accelerates, land scarcity is driving the deployment of photovoltaic (PV) arrays onto water bodies. Traditional floating photovoltaic (FPV) systems typically rely on complex networks of polyester ropes to link individual floats. However, as these "solar islands" scale up, rope-based systems become increasingly difficult to manage and allow for excessive relative motion, which increases the risk of collisions between floats.
Rigid steel connectors present a more stable and organized alternative. While they simplify the layout and improve collision safety, they introduce significant structural challenges. A connector that is too stiff may fail under intense wave forces, while one that is too flexible might compromise system stability. This research investigates the "Goldilocks" zone of connector design, balancing mechanical flexibility with structural integrity.
Methodology and Connector Modeling
The study utilizes a numerical simulation framework to evaluate the hydrodynamic performance of FPV modules under combined wave, wind, and current loads.
The researchers employed 3D Potential Flow Theory to calculate float motion and interactions, while the Lumped Mass Method was used to model the dynamic response of the mooring system. A central focus of the methodology was the comparison of three distinct single-rod rigid connector types, defined by their degrees of freedom (DOF):
- Purely Rigid: Zero DOFs released; maximum constraint.
- Hinged: One DOF (pitch) released.
- Cardan: Two DOFs (pitch and lateral rotation) released.
Simulations were conducted for arrays of two, four, and eight octagonal high-density polyethylene (HDPE) floats to analyze how system scaling impacts hydrodynamic loads.
Key Insights: Structural Vulnerabilities and Trade-offs
The analysis revealed several critical engineering considerations for large-scale FPV arrays:
- Central Load Concentration: In multi-float systems, the maximum connector loads consistently occur at the center of the array. These central connectors act as structural pivot points, making them the most vulnerable to failure as the system expands.
- The Cardan Paradox: While Cardan joints theoretically reduce loads by allowing more movement, they are susceptible to "self-locking" or jamming under specific wave conditions. This can lead to sudden spikes in bending moments that exceed those of simpler hinged joints.
- Collision Prevention: Rigid connectors are significantly more effective than polyester ropes at maintaining safe distances between floats. A rod length of 1.2m was found to effectively prevent collisions even in dense 8-float configurations.
- DOF Benefits: Moving from a purely rigid to a hinged design significantly reduces vertical loads and longitudinal bending moments, which is vital for extending the operational lifespan of steel components.
Results and Performance Metrics
- Moment Reduction: Cardan connectors reduced longitudinal moments by approximately 4.86 times compared to purely rigid setups, though they showed increased sensitivity to oblique waves.
- Optimal Dimensions: A connector length of 1.2m was identified as the optimal balance; shorter connectors (0.5m) led to instantaneous loads and collisions, while longer ones (1.9m) risked structural fracture due to insufficient stiffness.
- Scaling Impact: As the array grew from two to eight floats, the axial distance between floats decreased significantly, indicating that larger systems require either more robust external constraints or increased air gaps between modules.
Limitations and Future Outlook
While this study provides a foundation for rigid connector design, several challenges remain. The "self-locking" behavior of Cardan joints must be addressed to ensure reliability in harsh offshore environments. Furthermore, future research should incorporate long-term fatigue analysis for submerged steel components and expand the scope from 1D strings of floats to complex 2D grid arrangements typical of commercial FPV farms.
Summary updated