HACA3: A unified approach for multi-site MR image harmonization

Lianrui Zuo, Yihao Liu, Yuan Xue, Blake E. Dewey, Samuel W. Remedios, Savannah Hays, Murat Bilgel, Ellen M. Mowry, Scott D. Newsome, Peter A. Calabresi, Susan M. Resnick, Jerry L. Prince, Aaron Carass · DOI

Introduction

Magnetic Resonance (MR) imaging is a cornerstone of modern neuroimaging, yet it suffers from a significant lack of standardization. Variations in scanner hardware, field strengths, and pulse sequences across different clinical sites lead to "domain shift." This variability introduces bias into automated analysis tools, such as those used for brain volumetry or lesion segmentation, complicating multi-site clinical studies and longitudinal monitoring.

Figure 1: Comparison of inter-site and intra-site data scenarios for MR image harmonization, illustrating the challenges of domain shift across different subjects and scanner protocols.

Existing harmonization techniques often rely on rigid assumptions, such as the "identical anatomy" fallacy—the idea that different MR contrasts (e.g., T1-w and T2-w) of the same individual contain perfectly redundant anatomical information. Furthermore, many models are sensitive to image artifacts and require a fixed set of input modalities, limiting their real-world utility.

The HACA3 Framework

To address these limitations, we present HACA3 (Harmonization with Attention-based Contrast, Anatomy, and Artifact Awareness). HACA3 is an "encoder-attention-decoder" framework designed to disentangle image components and fuse them intelligently for high-fidelity synthesis.

Disentangled Representations

HACA3 employs three specialized encoders to decompose an input image into three distinct latent spaces:

  • Anatomy (β): Captures the underlying structural information.
  • Contrast (θ): Represents the site-specific and sequence-specific appearance.
  • Artifacts (η): Explicitly models noise and hardware-induced distortions.

Contrastive Learning for Anatomy

Rather than forcing anatomical representations from different contrasts to be identical, HACA3 utilizes contrastive learning. This approach encourages the model to recognize that patches from the same anatomical location in the same subject are similar, while still allowing for the unique tissue properties highlighted by different pulse sequences.

Attention-based Fusion and Dropout

The "secret sauce" of HACA3 is its Query-Key attention mechanism. During synthesis, the model evaluates the quality of available source images. If a specific contrast (e.g., a FLAIR scan) is corrupted by motion artifacts, the attention module automatically down-weights its anatomical contribution, relying instead on cleaner available contrasts like a T1-weighted image. To ensure flexibility, "attention dropout" is used during training, enabling the model to perform harmonization even when some input contrasts are missing at inference time.

Experimental Validation

The framework was validated using a comprehensive dataset spanning 21 different sites, including 11 public repositories (e.g., IXI, OASIS3, BLSA) and 10 clinical centers. The data encompassed both healthy controls and patients with Multiple Sclerosis (MS), covering four standard contrasts: T1-w, T2-w, PD-w, and FLAIR. A "gold standard" validation was performed using 12 "traveling subjects" who were scanned across multiple sites, providing a ground truth for direct numerical comparison.

Key Results and Impact

HACA3 demonstrates state-of-the-art performance across several metrics:

  • Image Fidelity: HACA3 significantly outperformed unsupervised methods like CycleGAN and supervised approaches like DeepHarmony in terms of Structural Similarity Index (SSIM) and Peak Signal-to-Noise Ratio (PSNR).
  • Clinical Utility: In a cross-site MS lesion segmentation task, domain shift originally caused Dice scores to drop from 0.593 to 0.348. HACA3 harmonization restored the score to 0.590, effectively neutralizing site-related bias.
  • Longitudinal Consistency: The model improved the Intra-class Correlation (ICC) for brain volume measurements, ensuring that observed changes reflect biological reality rather than scanner variability.

Conclusion and Future Work

HACA3 provides a robust, flexible solution for MR image harmonization. By explicitly modeling artifacts and leveraging attention-based fusion, it overcomes the rigidity of previous methods. Future work will explore spatial attention mechanisms—allowing the model to select anatomical details from different contrasts for specific brain regions—and extending the framework to other modalities such as CT or PET.

Reference: Zuo, L., et al. "HACA3: A unified approach for multi-site MR image harmonization." Preprint submitted to Elsevier (2023).

Summary updated

Abstract

Highlights•A unified harmonization approach that disentangles contrast and anatomy, while respecting inherent anatomical difference between MR contrasts.•A novel attention mechanism optimally processes anatomical information based on image contrast and artifacts.•Extensive evaluations on 21 imaging sites with diverse acquisition parameters and image quality.
BibTeX
@article{zuo2023haca,
  author = {Lianrui Zuo and Yihao Liu and Yuan Xue and Blake E. Dewey and Samuel W. Remedios and Savannah Hays and Murat Bilgel and Ellen M. Mowry and Scott D. Newsome and Peter A. Calabresi and Susan M. Resnick and Jerry L. Prince and Aaron Carass},
  title = {{HACA3: A unified approach for multi-site MR image harmonization}},
  journal = {Comput. Medical Imaging Graph.},
  year = {2023},
  doi = {10.1016/j.compmedimag.2023.102285},
}
Figure