Blake E. Dewey
· 3 previous affiliations
- Johns Hopkins UniversitySince 2015
- Assistant Professor · Since 2024
- Postdoc · 2021–2024
- Graduate Student · 2015–2021
- National Institutes of Health2013–2015
- Researcher · 2013–2015
- Vanderbilt University2009–2013
- Undergrad student · 2009–2013
Research Overview
Blake E. Dewey focuses on medical image analysis, specifically the harmonization of multi-site magnetic resonance imaging (MRI) and the enhancement of anisotropic volumetric scans. His trajectory spans statistical modeling for image registration to advanced deep learning techniques for super-resolution and cross-site consistency. Recent work investigates unsupervised quality assurance and anatomy-guided harmonization across diverse imaging modalities.
Research Trajectory
Early work by Dewey centered on statistical modeling and registration techniques to improve the efficiency and availability of quantitative magnetic resonance imaging (MRI). In 2016, he contributed to the development of methods for the Statistical estimation of Trelaxation times using conventional magnetic resonance imaging, which sought to generate reliable T1 maps without requiring specialized, time-consuming acquisition protocols. Building on this theme of computational efficiency, he introduced a novel registration technique in Efficient multi-atlas registration using an intermediate template image (2017). This work demonstrated that using an intermediate target could dramatically reduce the computation time required for multi-atlas label fusion while maintaining predictable segmentation accuracy.
As deep learning became more prevalent in medical image analysis, Dewey's focus shifted toward resolving data inconsistencies caused by varying scanner platforms and acquisition protocols—inconsistencies that often invalidate existing training data. He developed Deep Harmonization of Inconsistent MR Data for Consistent Volume Segmentation (2018), proposing an intensity harmonization method that jointly addressed contrast, resolution, and noise discrepancies. This evolved into a sustained focus on cross-site consistency. In 2020, he presented A Disentangled Latent Space for Cross-Site MRI Harmonization, which utilized limited supervision to harmonize images without relying on paired data from traveling subjects or making strict assumptions about anatomical similarities between populations. He further advanced this paradigm with collaborators in Unsupervised MR harmonization by learning disentangled representations using information bottleneck theory (2021), establishing a unified latent space that significantly improved downstream segmentation consistency. This line of inquiry also extended to multi-contrast synthesis, as seen in his contributions to Bi-directional Synthesis of Pre- and Post-contrast MRI via Guided Feature Disentanglement (2022).
Concurrently, Dewey made significant contributions to the research direction of Volumetric Neural Networks for Anisotropic Spatial Resolution. High-resolution MRI often requires long scan times, leading to a practical reliance on anisotropic acquisitions with high in-plane but low through-plane resolution. To mitigate the resulting aliasing artifacts, he co-developed SMORE: A Self-Supervised Anti-Aliasing and Super-Resolution Algorithm for MRI Using Deep Learning (2021). He later directed research extending these self-supervised super-resolution techniques to handle the challenging scenario of thick slices acquired with physical gaps, detailed in Self-Supervised Super-Resolution for Anisotropic MR Images with and Without Slice Gap (2023), which specifically addressed the domain shifts caused by variable acquisition resolutions. To support these and other downstream applications, he also helped train a StyleGAN3-based model to serve as A deep generative prior for high-resolution isotropic MR head slices (2023). More recently, his work in super-resolution has incorporated generative diffusion models. Recognizing that traditional conditional denoising diffusion probabilistic models (DDPMs) require hundreds of iterations during inference, he participated in the design of a time-strided approach to accelerate this process in TS-SR3: Time-Strided Denoising Diffusion Probabilistic Model for MR Super-Resolution (2024).
In 2025, Dewey's research expanded to address broader challenges in clinical machine learning, including the need for robust quality assurance and cross-modality generalization. He collaborated on An Unsupervised Approach for Artifact Severity Scoring in Multi-Contrast MR Images, introducing an interpretable framework to automate quality control and quantify artifact severity in large-scale, multi-site datasets. Additionally, he contributed to Optical Coherence Tomography Harmonization with Anatomy-Guided Latent Metric Schrödinger Bridges, a method that translates images across different scanner types while preserving underlying biological structures. This recent work reflects his ongoing engagement with the broader area of Addressing Class Imbalance in Clinical Machine Learning, ensuring that automated tools remain equitable, interpretable, and effective across diverse clinical environments and hardware platforms.
Current Directions
The most recent papers in the evidence indicate a continued focus on automating quality assurance and improving the cross-vendor generalization of medical imaging models. Recent work investigates unsupervised frameworks for scoring artifact severity in multi-contrast MRI, addressing the subjectivity and time constraints of manual quality control in high-throughput clinical workflows. Additionally, Dewey is exploring advanced generative frameworks, such as latent metric Schrödinger bridges, to harmonize imaging modalities like optical coherence tomography (OCT). These approaches aim to learn latent spaces where distances represent true anatomical differences rather than scanner-induced variations, ensuring that downstream clinical analysis remains robust across diverse hardware ecosystems.
Profile updated
| Paper | Venue | Year |
|---|---|---|
| Autoencoder based self-supervised test-time adaptation for medical image analysisGitHubheyufan1995/ | Medical Image Analysis | 2021 |
Loading new papers…
Other researchers whose papers cluster into the same research directions — a proxy for overlapping technical interests and shared intellectual neighborhoods.