Magnetic Resonance Unpaired Image Translation with Pseudometric Schrödinger Bridges

Shuwen Wei, Samuel W. Remedios, Zhangxing Bian, Shimeng Wang, Jinwei Zhang, Junyu Chen, Yihao Liu, Lianrui Zuo, Muhammad Faizyab Ali Chaudhary, Blake E. Dewey, Aaron Carass, Jerry L PrinceNeurIPS 2026

TL;DR

Translating MRI scans from one contrast (style) to another without paired training examples usually risks warping or hallucinating brain structures—a nightmare for clinical use. This paper introduces the Pseudometric Schrödinger Bridge (PMSB), a framework that maps different MRI contrasts into a shared, geometry-preserving anatomical space where identical brains can literally occupy the exact same coordinate. By closing the mathematical gap between domains before running diffusion, PMSB achieves state-of-the-art structural accuracy in unpaired medical image translation.

What Problem Does This Paper Address?

In multi-center medical studies, MRI datasets are notoriously messy: scanners vary, protocols differ, and certain contrast sequences (like $\text{T}_1$-weighted, $\text{T}_2$-weighted, or FLAIR) are often missing. Image translation fixes this by synthesizing missing contrasts. Because paired scans of the exact same patient are scarce, researchers rely on unpaired image translation.

Modern generative approaches like Diffusion Schrödinger Bridge Matching (DSBM) are great at matching overall image distributions. However, DSBM implicitly minimizes pixel-wise Euclidean distance. In MRI, two scans of the exact same brain under $\text{T}_1$-w (where fluid is dark) and $\text{T}_2$-w (where fluid is bright) are miles apart in Euclidean pixel space! Forcing a direct bridge between them causes the model to shift, warp, or hallucinate brain tissue.

A recent precursor, Latent Metric Schrödinger Bridge (LMSB), tried mapping images into an anatomy-guided latent space first. However, because it used a single shared mapping, it formed a strict metric space—forcing identical anatomies with different contrasts to remain separated by an artificial "transport gap."

Methods

PMSB eliminates this residual gap by generalizing the latent space from a strict metric space into a pseudometric space (where two distinct inputs are mathematically allowed to have a distance of zero).

Bidirectional translation pipeline using independent mappings and a latent bridge.

Here is how the two-stage recipe works:

  1. Independent Geometric Mappings (New): Instead of one shared encoder, PMSB trains two independent, invertible networks ($f_0$ and $f_1$) to map each MRI contrast toward a domain-agnostic anatomical target: discrete 4-class brain segmentation maps generated by an off-the-shelf tool (SynthSeg).
  2. Strict Function Constraints (New): Segmentation maps are blocky and lack microscopic detail. If $f_0$ and $f_1$ simply crushed the MRIs into flat cartoons, fine anatomy would be lost forever. To prevent this, the authors build $f_0$ and $f_1$ as volume-preserving diffeomorphisms using reversible affine coupling layers (borrowed from normalizing flows, where the Jacobian determinant is strictly $1$). Furthermore, they inject slight Gaussian noise into the inputs during training, which mathematically acts as a penalty encouraging approximate local isometry—preventing the network from stretching or squishing local anatomical distances.
  3. Bridging the Micro-Gap (Standard): Because $f_0$ and $f_1$ preserve fine details, they don't collapse all the way onto the coarse segmentation map; they land in closely overlapping latent spaces ($\Omega'_0$ and $\Omega'_1$). Standard DSBM (solved via Iterative Markovian Fitting and an ODE sampler) is then trained only across this tiny remaining gap. To translate an image, you push it forward into the latent space with $f_0$, hop across the short Schrödinger bridge, and invert it into the target contrast via $f_1^{-1}$.
LMSB keeps domains separate via a shared map, whereas PMSB uses independent maps to let domains overlap.

Datasets

The authors do not introduce new datasets, evaluating instead on two established public benchmarks:

  • OASIS-3: 402 unique subjects per task, split into unpaired training/validation slices (5,010 and 510 slices per domain) and 1,020 paired testing slices. They test pure contrast translation ($\text{T}_1$-w $\leftrightarrow \text{T}_2$-w, both 1 mm isotropic) and simultaneous contrast- plus resolution-translation ($\text{T}_1$-w $\leftrightarrow$ highly anisotropic FLAIR).
  • BraTS20: Used in an appendix evaluation to test generalizability on brains with severe tumor-induced deformations.

Key Insights and Ideas

  • Why Pseudometrics Matter: Under a strict metric, distance $d(x, y) = 0$ if and only if $x = y$. By switching to independent domain mappings ($f_0 \neq f_1$), the pullback metric becomes a pseudometric: a $\text{T}_1$-w scan and a $\text{T}_2$-w scan of the same brain are distinct images ($x_0 \neq x_1$), yet can map to the exact same latent coordinate ($f_0(x_0) = f_1(x_1)$), shrinking the work the diffusion model has to do.
  • Geometry Rescues Coarse Proxies: You don't need pixel-perfect anatomical ground truth to guide the latent space. Because invertible, volume-preserving, isometric networks literally cannot destroy volume or severely warp distances, fine brain folds and unsegmented details survive the trip into the latent space even though the training target is just a coarse 4-label segmentation map.
  • Noise as a Geometric Regularizer: Adding simple Gaussian noise to the input of a regression network isn't just data augmentation here—the authors prove it penalizes the trace of $df^\top df$, softly enforcing local Euclidean isometry without expensive Jacobian computations.

Key Results

Across the OASIS-3 tasks, PMSB establishes a new state-of-the-art in structural consistency, outperforming SynDiff, ContourDiff, UNSB, DSBM, and LMSB:

  • Overall Structural Metrics: PMSB achieves a mean PSNR of 26.70 dB, SSIM of 86.05%, and LNCC (local normalized cross-correlation) of 23.95%.
  • Biggest Gains on Hard Tasks: On the wide-gap $\text{T}_1$-w $\to \text{T}_2$-w task, PMSB hits 88.71% SSIM and 25.03 dB PSNR, trouncing vanilla DSBM (53.54% SSIM, 16.17 dB PSNR) and its direct predecessor LMSB (61.14% SSIM, 18.79 dB PSNR), while visually eliminating tissue hallucinations.
  • The Realism vs. Fidelity Trade-off: Direct pixel-space DSBM still wins on distribution-level realism (FID of 17.21 vs. PMSB's 23.75), and SDE sampling beats ODE sampling on FID—confirming a known trade-off where strict structural preservation slightly tempers raw generative sharpness.
  • Robustness: PMSB holds up well without pre-registration to an MNI template, tolerates artificially degraded (dilated) segmentation targets, and generalizes to tumor-heavy BraTS20 scans.

Limitations and Future Work

  • 2D Only (For Now): PMSB currently processes 2D axial slices independently, which can cause out-of-plane flickering or inconsistencies when stacked into a 3D volume. Scaling the invertible networks and diffusion bridge to full 3D volumes is a top priority.
  • Downstream Clinical Validation: While structural metrics look great, the synthesized scans still need to be validated on actual downstream clinical tasks (like automated disease diagnosis or volumetric measurements).
  • Architectural Quirks & Theory: The checkerboard spatial splitting used in the invertible layers introduces minor artifacts that require post-processing (upsampling/pooling) to smooth out. Future work aims to find cleaner invertible architectures, construct continuous latent manifolds directly without discrete segmentation proxies, and mathematically bound the exact magnitude of any remaining anatomical shift.

Summary updated

Abstract

Unpaired image translation is a critical preprocessing strategy for synthesizing missing sequences and harmonizing contrast variability in magnetic resonance imaging (MRI). However, in medical image processing, distribution-level translation is insufficient. It is vitally important that the anatomy is not distorted, corrupted, or lost after translation. Previous methods, like diffusion Schrödinger bridge matching (DSBM), achieve unpaired image translation, but do not preserve anatomy. We introduce the pseudometric Schrödinger bridge (PMSB), which trains two independent volume-preserving, isometry-regularized diffeomorphisms to map data from each domain to a latent anatomical pseudometric space. Then, DSBM is used within that space, explicitly minimizing the transport gap while preserving anatomy. Extensive experiments on the multi-contrast OASIS-3 dataset demonstrate that PMSB establishes a new state-of-the-art in structural consistency for cross-contrast synthesis. PMSB outperforms other leading methods and drastically reduces anatomical hallucinations, notably yielding a mean PSNR of 26.70 dB, a mean SSIM of 0.86, and a mean LNCC of 0.24.
BibTeX
@inproceedings{wei2026magnetic,
  author = {Shuwen Wei and Samuel W. Remedios and Zhangxing Bian and Shimeng Wang and Jinwei Zhang and Junyu Chen and Yihao Liu and Lianrui Zuo and Muhammad Faizyab Ali Chaudhary and Blake E. Dewey and Aaron Carass and Jerry L Prince},
  title = {{Magnetic Resonance Unpaired Image Translation with Pseudometric Schrödinger Bridges}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=ROSqb47snS},
}
Figure