Abstract: Clinically reliable perception of surgical scenes is essential for advancing intelligent, context-aware intraoperative assistance such as instrument handoff guidance, collision avoidance, and workflow-aware robotic support. Existing surgical tool benchmarks primarily evaluate category-level segmentation, requiring models to detect all instances of predefined instrument classes. However, real-world clinical decisions often require resolving references to a specific instrument instance based on its functional role, spatial relation, or anatomical interaction capabilities not captured by current evaluation paradigms. We introduce GroundedSurg, the first language-conditioned, instance-level surgical grounding benchmark. Each instance pairs a surgical image with a natural-language description targeting a single instrument, accompanied by structured spatial grounding annotations including bounding boxes and point-level anchors. The dataset spans ophthalmic, laparoscopic, robotic, and open procedures, encompassing diverse instrument types, imaging conditions, and operative complexities. By jointly evaluating linguistic reference resolution and pixel-level localization, GroundedSurg enables a systematic and realistic evaluation of vision-language models in clinically realistic multi-instrument scenes. Extensive experiments demonstrate substantial performance gaps across modern segmentation and VLMs, highlighting the urgent need for clinically grounded vision-language reasoning in surgical AI systems.
Introduction
In a real operating room, a surgeon doesn't just need an AI to identify all forceps in a scene. They need the system to understand which forceps are currently retracting tissue versus which are idle. Existing benchmarks primarily focus on category-level segmentation, identifying all instances of a predefined class. However, clinical decision-making requires instance-level grounding: resolving references to a specific tool based on its interaction with anatomy or its spatial position.
To address this gap, we introduce GroundedSurg, a new benchmark designed to move surgical AI from simple object detection to context-aware reasoning. By pairing surgical images with natural language descriptions (e.g., "the scissors dissecting the stomach tissue"), it challenges models to identify and segment specific instrument instances based on their functional roles and spatial relationships.
Methodology
The GroundedSurg benchmark formalizes surgical tool perception as a language-conditioned, instance-level segmentation task. The data was curated using a semi-automated pipeline where a Vision-Language Model (VLM), specifically Qwen-2.5, generated initial queries based on image content and spatial data. These queries were then rigorously reviewed and refined by clinicians to ensure semantic correctness and remove ambiguity.
Models are evaluated in a zero-shot setting using a "grounding-then-segmenting" approach. They must predict structured localization outputs, such as bounding boxes and center points, which are then projected onto a frozen Segment Anything Model (SAM) backend to generate final pixel-level masks. Evaluation metrics include both region-based measures (IoU, Dice) and localization metrics (BBox IoU, Normalized Distance Error) to assess how well the model understood the linguistic reference.
The GroundedSurg Dataset
GroundedSurg aggregates and re-annotates samples from several public sources, including InSeg, SISVE, EndoVis, and CholecInstanceSeg.
- Scale: ~612 surgical images and 1,071 tool-level annotations.
- Diversity: Covers four major procedure types: ophthalmic, laparoscopic, robotic, and open surgery.
- Uniqueness: Unlike previous datasets like CaDIS or AutoLaparo, GroundedSurg is the first to support multi-procedure data paired with natural language conditioning and explicit spatial grounding.
Key Results and Insights
Extensive experiments reveal a significant performance gap in current VLMs when applied to complex surgical scenes.
- Reasoning vs. Scale: "Reasoning-oriented" models, such as VisionReasoner-7B, consistently outperformed general-purpose VLMs, achieving the best spatial precision (BBox IoU of 0.34). Qwen2.5-VL-7B showed the strongest coarse grounding ([email protected] of 0.52).
- The Performance Gap: Performance plummets when evaluated at stricter thresholds ([email protected] and beyond). While AI can often "see" the tool in a general sense, it struggles with the precise boundary delineation required for safe surgery.
- Qualitative Failures: General VLMs often suffer from "contextual leakage," where the predicted mask bleeds into adjacent instruments or anatomical structures—a dangerous error in a surgical context.
Conclusion
GroundedSurg highlights that current state-of-the-art models are still far from being "clinically reliable." The results suggest that grounding—the ability to link text to a specific visual instance—is a distinct reasoning skill not automatically acquired through general medical pretraining. Future work must focus on architectures that better integrate linguistic reasoning directly into spatial perception layers and extend these capabilities to real-time video grounding for intraoperative assistance.
Summary updated