Field tests of airfield lighting cable connections

James Davis1963 · DOI

Abstract

This report summarizes a four-year longitudinal study conducted by the National Bureau of Standards (NBS) beginning in 1963. The research investigated the long-term insulation resistance of various airfield lighting cable connections buried in soil. By tracking performance under real-world conditions, the study identified critical factors in connection longevity, including the surprising impact of cable preparation techniques and the resilience of standard connector types against continuous electrical stress.

Introduction

In the early 1960s, airfield lighting systems faced a persistent challenge: cable connections that passed initial specifications often failed prematurely once buried. These systems, which utilize series circuits at potentials up to 5,000V, are the literal lifelines of runway safety. To address the lack of longitudinal data on buried insulation performance, the NBS initiated a multi-year field test to determine how moisture, soil exposure, and electrical potential affect the integrity of cable splices over time.

Experimental Methodology

The researchers established a controlled 10x10 foot burial plot, excavated to a depth of two feet. Thirteen test units were installed, representing three primary connection technologies of the era:

  1. Molded Rubber Connectors: A'G'A Style E plug-and-receptacle units.
  2. Resin-Cast Splices: 3M "Scotchcast" epoxy resin kits.
  3. Vulcanized Splices: Portable vulcanizer units from Joy Manufacturing.

To isolate the electrical leakage occurring specifically at the connection points, the team employed a guard circuit with guard rings on the cable ends. A subset of the units was subjected to a continuous 2,400V potential to simulate operational stress. Measurements were recorded every spring and autumn to account for seasonal fluctuations in soil moisture.

The "Pencilling" Paradox

One of the study's most significant findings challenged standard installation practices. It was common for technicians to "pencil" (taper) cable insulation before applying tape, aiming for a smooth transition. However, the NBS data revealed that square-cut cable ends actually provided superior protection. Taping over a sharp corner created a more effective mechanical seal against moisture ingress than taping over a long, tapered slope, which tended to allow more electrical leakage.

Long-Term Performance and Safety Margins

Over the course of four years, the insulation resistance of the molded connectors typically degraded by approximately 50%, dropping from initial values of ~60,000 megohms to ~30,000 megohms. Despite this significant decrease, the performance remained well within safety parameters.

Key results included:

  • Resilience: All connections maintained resistance levels between 8,000 and 50,000 megohms, far exceeding the 3,000 megohm minimum required by Military and FAA specifications.
  • Voltage Stress: The application of a continuous 2,400V potential did not accelerate deterioration, suggesting that environmental factors like moisture ingress are more critical than constant electrical potential.
  • Leakage Sources: The study demonstrated that the majority of measured leakage in airfield circuits often originates from the cable jacket or buried ends rather than the splices themselves.

Conclusion

The NBS field tests confirmed that properly installed airfield lighting connections are robust enough to withstand years of burial. The study highlighted that field failures are more likely the result of poor "care and cleanliness" during installation—such as trapping dirt or oils under tape—rather than inherent design flaws. While the study did not account for thermal cycling from load currents, it provided a vital baseline for the maintenance and specification of airfield electrical infrastructure.

Summary updated

Abstract

Functions and ActivitiesI'he functions of the National Bureau of Standards include the development and maintenance of the national standards of measurement and the provision of means and methods for making measure ments consistent with these standards; the determination of physical constants and properties of materials; the development of methods and instruments for testing materials, devices, and struc- tures; advisory services to government agencies on scientific and technical problems; invention and development of devices to serve special needs of the Government; and the development of standard practices, codes, and specifications, including assistance to industry, business and con- sumers in the development and acceptance of commercial standards and simplified trade practice recommendations.The work includes basic and applied research, development, engineering, instrumentation, testing, evaluation, calibration services, and various consultation and information serv- ices.Research projects are also performed for other government agencies when the work relates to and supplements the basic program of tbe Bureau or when the Bureau's unique competence is re- quired.The scope of activities is suggested by the listing of divisions and sections on the inside of the back cover. PublicationsTbe results of the Bureau's research are published either in the Bureau's own series of publi- cations or in the journals of professional and scientific societies.The Bureau itself
BibTeX
@misc{davis1963field,
  author = {James Davis},
  title = {{Field tests of airfield lighting cable connections}},
  year = {1963},
  doi = {10.6028/nbs.rpt.8106},
}
Figure