Abstract: Two barrier RF systems were fabricated, tested, and installed in the Fermilab Main Injector. Each provides 8 kV rectangular pulses at 90 kHz. By combining a stationary barrier with a moving barrier, injected beams from the Booster can be continuously deflected, folded, and stacked in the Main Injector, leading to a doubling of beam intensity. This paper reports on beam experiments using this novel technology.
Introduction
In high-energy physics, beam power is a critical performance metric. Historically, the Fermilab Main Injector (MI) was limited by the number of proton pulses it could accept from the Booster accelerator. Standard operations allowed for only 6 or 7 pulses due to injection timing constraints and the physical longitudinal space each pulse occupied. To support high-intensity projects such as the NOvA experiment, a method was needed to increase the number of protons delivered to targets. While "slip stacking" was under investigation, this research explores the use of RF barriers to physically compress and "fold" the beam, significantly increasing packing density.
Methods and Experimental Setup
The experimental setup involved two specialized barrier RF systems installed in the Main Injector. Unlike traditional RF systems that utilize sine waves to create "buckets," these systems generate 8 kV rectangular pulses at 90 kHz.
The "Fast Stacking" process relies on three primary mechanisms:
- Momentum Offset: The injected beam is intentionally given a momentum offset ($\Delta p/p = -0.196\%$) via a shift in the injection RF frequency. The accelerator's "slip factor" causes particles with different momenta to travel at different speeds, inducing a controlled drift.
- Stationary Barrier: A fixed RF pulse acts as a "reflecting wall," preventing previously injected pulses from drifting into the longitudinal space reserved for subsequent injections.
- Moving Barrier: A second RF pulse moves at a specific velocity (0.8 $\mu$s per Booster cycle) to reduce momentum spread and facilitate tight stacking against the stationary barrier.
By precisely timing these barriers, the researchers successfully reduced the spacing between consecutive pulses from the standard 1.6 $\mu$s to 0.8 $\mu$s.
Key Insights
- Leveraging the Slip Factor: A critical insight involved managing the frequency shift between the Booster and the Main Injector. Because the slip factor has opposite signs in each machine, a higher RF frequency at injection creates the necessary drift for stacking.
- Fast vs. Slow Stacking Efficiency: Unlike "slow" stacking, which relies on gradual adiabatic compression, this "fast" method utilizes the natural drift of a momentum-offset beam, making it highly efficient for high-repetition-rate operations.
- Barrier Diagnostics: The RF barrier serves as a diagnostic tool. By lowering the barrier voltage until particles "leak" over the wall, the beam's momentum spread can be directly measured.
Results and Discussion
The system successfully demonstrated the injection of 12 Booster pulses into the Main Injector, doubling the standard capacity. Experimental data showed that the total width of 6 stacked pulses could be reduced to 5.5 $\mu$s—less than half of their original 9.6 $\mu$s footprint.
The stacked beam was successfully recaptured by the primary 53 MHz RF system and accelerated to 120 GeV. Furthermore, the "barrier penetration" method allowed the team to measure the Booster beam's energy spread at $\pm 6.1$ MeV.
Limitations and Future Directions
The primary challenge identified was beam loss during the transition to the main acceleration RF. This loss is attributed to "dc beam"—particles that were not captured into the 53 MHz RF buckets. Future work will focus on optimizing the RF recapture procedure through refined simulations and experiments to eliminate these losses, ensuring the system's viability for routine high-power operations.
Summary updated