Error assessment of microwave holography inversion for shallow buried objects

Emanuele Vivoli, Luca Bossi, Marco Bertini, Pierluigi Falorni, Lorenzo Capineri

Abstract

Holographic imaging is a technique that uses microwave energy to create a three-dimensional image of an object or scene. This technology has potential applications in land mine detection, as the long-wavelength microwave energy can penetrate the ground and create an image of hidden objects without the need for direct physical contact. However, the inversion algorithms commonly used to digitally reconstruct 3D images from holographic images, such as Convolution, Angular Spectrum, and Fresnel, are known to have limitations and can introduce errors in the reconstructed image. Despite these challenges, the use of holographic radar at around 2 GHz in combination with holographic imaging techniques for land mine detection allows to recover size and shape of buried objects. In this paper, we estimate the reconstruction error for the convolution algorithm based on hologram imaging simulation and assess these errors recommending an increase in the scanner area, considering the limitations that the system has and the expected error reduction.

Introduction

Holographic Subsurface Radar (HSR) is a promising tool for non-contact detection of buried land mines. By moving a radar antenna over a grid to create a "synthetic aperture," the system generates holographic data that can be mathematically inverted to reconstruct 3D images of subsurface objects. However, the accuracy of these images is often compromised by two primary factors: the inherent limitations of standard reconstruction algorithms (like Convolution or Angular Spectrum) in the near-field, and the physical constraints of portable robotic scanning platforms.

Conceptual diagram of Holographic Subsurface Radar (HSR) scanning a buried landmine, showing the scanning grid plane and depth $Z_0$.

In holography, the scanning area acts as a spatial filter. A small scanner effectively functions as a "pinhole," filtering out high-frequency spatial data necessary for defining sharp object edges. This research quantifies how the physical size of the scanning area affects reconstruction accuracy, aiming to identify an optimal balance between image fidelity and robotic portability.

Methods

The study employed a simulation-based approach using the HoloPy Python library to model forward wave propagation and backward reconstruction. The researchers focused on microwave holography at 2 GHz, validating the physics against optical-scale simulations.

Reconstruction and Metrics

The Convolution and Angular Spectrum methods were evaluated for their performance in near-field imaging. To quantify reconstruction quality, a dual-loss error metric was used:

  1. Classical L2 Loss: Measures the overall difference between the original object and its reconstruction.
  2. $L2_{loss\_zero}$: A specialized metric focusing on noise and artifacts in the "empty" space surrounding the target, which is critical for distinguishing mines from background clutter.

Data Sources

Simulations were performed on polystyrene spheres to establish baseline error curves. These findings were then compared with real-world holographic data from a PMN4 landmine and a terracotta vessel, collected using the "UGO-1st" robotic platform.

Results and Discussion

The analysis revealed that error reduction is non-linear. A significant "local minimum" in the error curve suggests that specific increases in scanner size yield disproportionately large gains in clarity.

A simulated microwave hologram (left) and its corresponding reconstruction at a depth of z=4.5 (right), illustrating the noise and artifacts inherent in the inversion process.

Key findings include:

  • The 11 cm Breakthrough: Increasing the detector dimension by 11 cm (adding 22 pixels to the grid) resulted in a 63.7% reduction in reconstruction error.
  • Optimal Dimensions: For objects buried at approximately 8 cm, a scanner dimension of 63 x 73 cm is recommended for high-fidelity imaging.
  • Practical Constraints: While a 50 cm increase would further reduce error by 71.7%, such a change is mechanically unfeasible for current portable robots like the UGO-1st. The 11 cm increase represents the most practical engineering recommendation.

Conclusion

This study demonstrates that modest increases in the scanning aperture of HSR systems can dramatically improve the detection and identification of buried objects. While real-world errors remain higher than simulations due to soil complexity and hardware noise, optimizing the scanner geometry provides a clear path forward. Future work will focus on testing these optimized dimensions in diverse soil conditions and mitigating the mechanical impact of larger scanning frames on robotic stability.

Summary updated

Abstract

Holographic imaging is a technique that uses microwave energy to create a three-dimensional image of an object or scene. This technology has potential applications in land mine detection, as the long-wavelength microwave energy can penetrate the ground and create an image of hidden objects without the need for direct physical contact. However, the inversion algorithms commonly used to digitally reconstruct 3D images from holographic images, such as Convolution, Angular Spectrum, and Fresnel, are known to have limitations and can introduce errors in the reconstructed image. Despite these challenges, the use of holographic radar at around 2 GHz in combination with holographic imaging techniques for land mine detection allows to recover size and shape of buried objects. In this paper, we estimate the reconstruction error for the convolution algorithm based on hologram imaging simulation and assess these errors recommending an increase in the scanner area, considering the limitations that the system has and the expected error reduction.
BibTeX
@misc{vivoli2023error,
  author = {Emanuele Vivoli and Luca Bossi and Marco Bertini and Pierluigi Falorni and Lorenzo Capineri},
  title = {{Error assessment of microwave holography inversion for shallow buried objects}},
  year = {2023},
  eprint = {2303.15335},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2303.15335},
}
Figure