Abstract
Purpose: Long-leg-radiography (LLR) is commonly used for measurement of lower limb alignment. However, limb rotations during radiography may interfere with the alignment measurement. This study examines the effect of limb rotation on the accuracy of measurements based on the mechanical and anatomical axes of the femur and tibia, with variations in knee flexion and coronal deformity. Methods: Forty-five lower limbs of thirty patients were scanned with CT. Virtual LLRs simulating 5 rotational positions (neutral, ±10°, and ±20° internal rotation) were generated from the CT images. Changes in the hip-knee-ankle angle (HKA) and the femorotibial angle (FTA) were measured on each image with respect to neutral values. These changes were related to knee flexion and coronal deformity under both weight- and non-weight-bearing conditions. Results: The measurement error of the HKA and FTA derived from limb rotation were up to 4.84±0.66° and 7.35±0.88° respectively, and were correlated with knee flexion (p<0.001) and severe coronal deformity (p≤0.001). Compared with non-weight-bearing position, coronal deformity measured in weight-bearing condition was 2.62° greater. Conclusion: Flexion and severe coronal deformity have significant influence on the measurement error of lower limb alignment. Errors can be amplified in the weight-bearing condition. The error of measurement of the anatomic axis is greater than the mechanical axis.
Introduction
In orthopedic surgery, particularly for Total Knee Arthroplasty (TKA) or osteotomies, precise alignment is critical for successful outcomes. Surgeons traditionally rely on Long-Leg Radiography (LLR) to measure the mechanical and anatomical axes of the leg to plan surgical interventions. The gold standard measurement is the Hip-Knee-Ankle (HKA) angle.
However, an LLR is a 2D projection of a 3D structure. If a patient’s leg is rotated internally or externally during the X-ray, the projected angles change. This study addresses a critical gap: how existing deformities—such as a knee that cannot fully straighten (flexion contracture) or a severely bowed leg—interact with limb rotation to worsen these measurement errors. For patients with advanced osteoarthritis, these errors can lead to a misdiagnosis of their actual alignment.
Methods and Materials
The researchers combined clinical imaging with computational modeling to isolate the effects of rotation. The study utilized a clinical dataset of 30 patients (45 lower limbs) recruited between 2018 and 2019, with a median age of 67.
Using 3D CT data, the team generated "virtual LLRs" to precisely control limb rotation at five specific increments: neutral (0°), ±10°, and ±20° of internal rotation. They measured two primary angles:
- HKA (Hip-Knee-Ankle): The angle between the mechanical axes of the femur and tibia.
- FTA (Femorotibial Angle): The angle between the anatomical axes (the midshafts) of the bones.
The virtual (non-weight-bearing) images were also compared to real standing weight-bearing LLRs to determine how joint loading affects measurements.
Key Results
Anatomical vs. Mechanical Axis Sensitivity
The study found that the anatomical axis (FTA) is significantly more sensitive to rotational errors than the mechanical axis (HKA). Limb rotation caused measurement errors of up to 4.84° ± 0.66° for the HKA and 7.35° ± 0.88° for the FTA.
The "Deformity Multiplier"
A critical finding is that rotation error is not constant; it is amplified by the severity of existing deformities. Errors were highly correlated with knee flexion ($p < 0.001$) and severe coronal deformity ($p \leq 0.001$). Patients in the "severe" deformity categories showed dramatically higher error ranges, indicating that the most complex cases are also the most difficult to measure accurately with 2D X-rays.
Weight-Bearing Amplification
Standing up (weight-bearing) increased the measured coronal deformity by an average of 2.62° compared to non-weight-bearing virtual models. Furthermore, the correlation between deformity and rotation-induced error was found to be stronger in weight-bearing conditions.
Discussion and Conclusion
While LLR is the clinical gold standard, this study quantifies that in severe cases, measurements can be off by nearly 5 degrees—a significant margin when surgical targets often aim for a precision of ±3°.
Limitations include the use of supine CT scans for the virtual models and a relatively small sample of patients with severe deformities. Future work should explore more rigorous standardized positioning protocols or 3D imaging for patients with complex, multi-planar deformities to avoid surgical planning errors. In conclusion, surgeons should be particularly attentive to potential errors in weight-bearing radiographs of patients with severe knee deformities.
Summary updated