Decision-Native Multimodal Clinical Modeling via Anatomical Grounding and Confidence Calibration

Juntao Jiang, Wenqi Zhong, Guangyu Guo, Dexia Chen, Yilong Hu, Yunhao Bai, Zhenyu Yi, Jianwei Xu, Tony C. W. Mok, Muxuan Gao, Ling Zhang, Yong Liu, Jiangning Zhang, Zhongwei Qiu

TL;DR

When AI reads a 3D CT scan, generating a chatty paragraph is easy, but knowing when to trust its own judgment is remarkably hard. Radev replaces standard text generation with a "decision-native" architecture that zeroes in on the exact organ being queried and produces genuinely calibrated probabilities in a single pass. That means when Radev says it is 62% sure about a diagnosis, it actually gets it right about 62% of the time—giving clinicians a reliable dial to automate clear-cut cases and flag ambiguous ones for human review.

Generative VLMs vs. Decision-Native VLMs

What Problem Does This Paper Address?

Imagine asking a medical Vision-Language Model (VLM), "Is hepatic steatosis present in the liver?" Most existing models treat this as an open-ended writing prompt, autoregressively predicting one word at a time. In high-stakes clinical workflows, this setup hits three major roadblocks:

  1. Overconfident hallucinations: Token-by-token probabilities are notoriously poorly calibrated. Models routinely output wrong answers with near-100% mathematical certainty, making it impossible to automatically flag uncertain cases for a radiologist.
  2. The 3D-to-2D squeeze: Volumetric CT scans contain hundreds of slices—too many tokens for standard LLMs. Compressing the whole 3D volume loses tiny lesions on 2D slices, while sampling raw 2D slices loses 3D anatomical context.
  3. Shortcut learning: Models supervised only on final answers often cheat, relying on spurious background correlations (like fluid elsewhere in the abdomen or scanner artifacts) rather than actually inspecting the queried organ.

Methods

Instead of generating free text, Radev reframes CT interpretation as a single-pass, closed-set decision over explicit candidate options (e.g., Yes/No, multiple-choice attributes, or severity levels 0–4) built atop a standard Qwen3.5 backbone and a frozen 3D segmentation-and-encoding network (RADAR). Two novel mechanisms drive the system:

  • Organ-Grounded Visual Compression: First, the frozen 3D encoder extracts features for 36 distinct organs plus one global volume slot, storing them in a compact, reusable "organ ledger." When a clinical question arrives, a text router identifies the target organ(s). Only those specific organ tokens use cross-attention to pull in high-resolution 2D slice details—strictly bounded within that organ's 3D box. The LLM receives a tiny set of rich, anatomy-specific visual tokens and scores all candidate answers in one forward pass.
  • Counterfactual-Calibrated Training (CCT): After standard alignment and fine-tuning (using cross-entropy, Brier score, and ranked probability losses), Radev undergoes an intervention-based bootcamp. For every question, the model sees four realities: Factual (intact scan), Control-Ablated (a random unrelated organ erased), Target-Ablated (the queried organ erased), and Evidence-Blind (all image features erased). By supervising ablated views against the true label and applying a margin penalty on the blind view, CCT teaches Radev to stay confident when irrelevant organs vanish, temper its confidence toward empirical priors when the target organ is missing, and drop confidence sharply when blinded.
Framework of Radev and Counterfactual-Calibrated Training

Datasets

To test structured clinical decisions rather than free-text prose, the authors introduce CT-Verdict, a new benchmark built by parsing radiology reports into structured records and verifying them with multiple LLM readers and human audits:

  • CT-Verdict-IID (In-Distribution): Sourced from Merlin-CT (25,270 abdominal CT studies for training and testing). The test split spans 56,825 binary, multiple-choice, and ordinal severity questions across 17 organ systems and 30 clinical findings.
  • CT-Verdict-OOD (Out-of-Distribution): An external, multi-center test cohort sourced from AMOS-MM (421 CT studies, 2,055 questions across 12 organ systems) to test robustness across different hospitals and scanners.

Key Insights and Ideas

  • Most medical VLMs have worse-than-useless confidence scores: When decomposing calibration quality, 14 out of 22 baseline models performed worse than a "constant-confidence" dummy baseline that simply reports its overall average accuracy on every single case. High task accuracy does not imply trustworthy uncertainty.
  • Erasing evidence naturally cures overconfidence: During CCT, Radev isn't fed artificial "50/50" soft labels when target organs are hidden. Simply supervising indistinguishable target-ablated views with the original ground-truth labels mathematically pulls the model's predictions back toward the natural disease prevalence—organically curing overconfidence.
  • Anatomy-gated fusion beats brute-force tokens: Simply concatenating 2D slices and 3D features barely improves over a 3D encoder alone. Restricting 2D cross-attention strictly inside 3D organ bounding boxes lets Radev scale up to 32 slices with steady accuracy gains and zero token dilution.

Key Results

Across 22 open- and closed-source baselines (including GPT-5.4, Merlin, ClinFusion-8B, and 2D decision models), Radev dominates in both accuracy and calibration:

  • State-of-the-art accuracy: On CT-Verdict-IID, Radev-2B hits 83.75% overall accuracy (90.08% on binary, 71.33% on multiple-choice, and 0.39 MAE on 0–4 severity), outperforming much larger 7B–9B models and beating closed-source GPT-5.4 by ~19% overall. Even the tiny Radev-0.8B beats every baseline.
  • Order-of-magnitude better calibration: Radev slashes Expected Calibration Error (ECE) down to 0.01–0.02 across tasks (a 10× to 100× error reduction over top baselines).
  • Actionable clinical deferral: If a hospital configures Radev-2B to defer its least confident 20%, 40%, or 50% of cases to human radiologists, accuracy on the automated cases climbs smoothly from 83.8% to 90.0%, 95.2%, and 97.0% (compared to just 77.6% at 50% deferral for the strongest baseline).
  • Zero-shot external generalization: On the external AMOS-MM cohort (CT-Verdict-OOD), Radev-2B achieves 72.72% binary and 69.29% multiple-choice accuracy (+9% and +16% over GPT-5.4), while cutting ordinal probabilistic error (KRPS) by 3.8× compared to the best baseline.

Limitations and Future Work

Because Radev is purpose-built as a closed-set decision engine, it exposes no free-text generation path—it is designed for structured clinical verdicts rather than open-ended report writing. Furthermore, its current 36-slot organ ledger and evaluations are focused on abdominal CT scans. The authors plan to expand both the organ-grounded ledger and counterfactual calibration framework to broader anatomical regions (such as chest or head/neck) and other complex volumetric modalities, particularly multi-sequence MRI.

Summary updated

Abstract

Structured clinical decisions from volumetric computed tomography (CT) require anatomically grounded predictions and calibrated confidence estimates. However, existing 3D medical multimodal models often suffer from uncalibrated autoregressive decoding and shortcut reliance on irrelevant anatomical regions. We introduce Radev, a decision-native multimodal model that integrates anatomy-guided visual compression, direct candidate prediction, and counterfactual confidence supervision. To bridge global context with fine-grained slice details, a frozen 3D encoder extracts reusable organ-level features, which are dynamically selected by the query to attend to 2D slice features within predicted anatomical bounds. The resulting compact visual tokens enable the language backbone to estimate candidate probabilities in a single forward pass without autoregressive decoding. We further propose Counterfactual-Calibrated Training (CCT) to compare predictions under intact and intervened organ representations. CCT encourages confidence to decrease when removing target-organ evidence degrades decision quality, while penalizing excessive confidence drops under unrelated-organ removal. To facilitate rigorous evaluation, we construct CT-Verdict, a comprehensive benchmark spanning binary finding presence, multiple-choice questions, and ordinal severity assessment across both in-distribution and external cohorts. Extensive experiments demonstrate that Radev significantly outperforms state-of-the-art methods in both decision accuracy and confidence calibration, while generalizing robustly under distribution shifts. Project page at https://juntaojianggavin.github.io/projects/Radev/
BibTeX
@misc{jiang2026decision,
  author = {Juntao Jiang and Wenqi Zhong and Guangyu Guo and Dexia Chen and Yilong Hu and Yunhao Bai and Zhenyu Yi and Jianwei Xu and Tony C. W. Mok and Muxuan Gao and Ling Zhang and Yong Liu and Jiangning Zhang and Zhongwei Qiu},
  title = {{Decision-Native Multimodal Clinical Modeling via Anatomical Grounding and Confidence Calibration}},
  year = {2026},
  eprint = {2611.32993},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.32993},
}
Figure