Abstract: The steel-concrete composite bridge tower serves as the primary load-bearing component in long-span cable-supported bridges. The connection design between concrete and steel elements requires meticulous consideration during structural engineering practice. To investigate the load transfer mechanism and elastic-plastic behavior of steel-concrete connections, this study develops a refined finite element model using the ABAQUS platform. Through analysis of stress distribution patterns across components under various design load combinations, the ultimate elastic-plastic capacity and plastic deformation characteristics were evaluated against conventional configurations. Results demonstrate that concrete elements and shear connectors maintain effective within the elastic range. During progressive plastification phases, pronounced stress concentrations develop at the steel-concrete interface, particularly in connector weldment zones.
Introduction
In modern long-span cable-stayed bridges, composite towers—which combine the compressive strength of concrete with the tensile strength and stiffness of steel—are becoming the structural standard. However, the most vulnerable part of these structures is the transition zone: the specific section where the upper steel-concrete composite segment connects to the lower pure-concrete segment. Because these materials behave differently under stress, the load transfer mechanism at this interface is incredibly complex. This research utilizes refined finite element analysis to investigate these transition zones, revealing significant safety margins alongside intense stress concentrations at material interfaces during extreme loading.
Methodology and Modeling
The study developed a high-fidelity 3D simulation using the ABAQUS finite element platform. The modeling approach employed specialized elements for different materials: shell elements (S4R) for steel plates, solid hexahedral elements (C3D8R) for the concrete core and shear studs, and truss elements (T3D2) for internal rebar.
To capture realistic behavior, the authors used a Concrete Damaged Plasticity (CDP) model, accounting for cracking under tension and crushing under compression, including stiffness recovery during cyclic loading. The simulation also accounted for physical friction and "hard contact" between steel plates and concrete, as well as the integrated relationship of the shear studs. The model was subjected to combined axial forces and bending moments to simulate unfavorable real-world conditions.
Case Study Parameters
The simulation was based on a real-world cable-stayed bridge tower with the following specifications:
- Materials: Q355D steel plate, HRB400 reinforcement bars, and C50 grade concrete.
- Geometry: A 10-meter tall segment consisting of a 5m composite section and a 5m concrete section.
Key Insights and Structural Performance
Analysis of the model revealed several critical behaviors of the connection section:
- The "Corset" Effect: The outer steel plate acts as a rigid restraint for the concrete core. Near ultimate load, the upper composite section exhibits minimal lateral deformation because the steel casing holds the concrete in place, whereas the lower, unreinforced concrete segment deforms significantly more.
- Stiffness vs. Capacity: The composite connection section has lower structural stiffness in the elastic stage compared to a standard section, deforming about 30% more before reaching its elastic limit, despite its high ultimate capacity.
- Stress Hotspots: Failure is non-uniform. Pronounced stress concentrations occur specifically at transition points, particularly near the fillet welds of connectors and the ends of stiffeners.
Results and Safety Evaluation
Under standard design loads, all components remain well within their elastic range. The maximum Mises stress in the steel was recorded at 139.4 MPa, significantly below the 355 MPa yield point. The elastic ultimate capacity was measured at $6.93 \times 10^5$ kN, while the plastic ultimate capacity reached $1.19 \times 10^6$ kN. Compared to standard sections, the connection's plastic capacity is approximately 8.5% lower, but it demonstrates 7.7% more displacement before failure, indicating higher ductility.
Conclusion and Future Recommendations
The study identifies the abrupt end of the steel casing as a primary source of stress concentration. To mitigate this, the authors suggest extending longitudinal stiffeners from the upper steel box further into the lower concrete segment. Furthermore, given the massive safety reserves identified ($1.19 \times 10^6$ kN capacity vs. design loads), there is significant potential to downsize these structures to save materials and reduce the environmental footprint of bridge construction.