Abstract
In modern urban residential design, "special-shaped" columns (L, T, or X-shaped) are preferred for their ability to be concealed within wall intersections, thereby increasing usable floor area. However, traditional reinforced concrete special-shaped columns often exhibit poor seismic performance. This research investigates a novel structural solution: L-shaped columns composed of multiple concrete-filled steel tubes (SCFT). This paper presents an experimental and numerical study on the behavior of these columns under axial and eccentric loading, focusing on failure modes, component cooperation, and the development of a simplified design formula.
The Challenge of Special-Shaped Columns
Traditional rectangular columns often protrude into living spaces, creating architectural constraints. While special-shaped columns solve this, standard concrete-filled steel tubular (CFST) designs often require internal tie rods to ensure proper interaction between the steel shell and concrete core, which can be difficult to fabricate. The proposed SCFT design utilizes several smaller "mono-columns" connected by steel plates and stiffeners to achieve high strength and ductility while maintaining a clean architectural profile.
Methodology
The study employed a three-pronged approach to validate the SCFT design:
- Experimental Testing: Three L-shaped specimens were fabricated and tested under different loading conditions: pure axial compression (S-3), uniaxial bending (S-1), and biaxial bending (S-2). The specimens were instrumented with 92 strain gauges and 16 dial meters to monitor deformation and stress distribution.
- Finite Element Analysis (FEA): 3D models were developed using ANSYS, employing SHELL 181 elements for steel and SOLID 65 for concrete. The models accounted for complex contact mechanics, including friction and potential separation between the steel and concrete.
- Analytical Derivation: A simplified calculation formula was derived by treating the multi-tube assembly as a lattice structure, simplifying connection plates into equivalent lacing bars for easier engineering application.
Key Findings
Structural Synergy
The experimental results confirmed that the mono-columns work together effectively as a single unit. The connection plates ensured the assembly acted as a single unit, preventing individual tubes from failing prematurely and ensuring the assembly reached its full structural potential.
Impact of Eccentric Loading
Eccentric loading—where the load is applied off-center—was found to be the critical design condition. The ultimate bearing capacity for specimens under eccentric load (S-1 and S-2) was approximately 57% lower than the axial control specimen (S-3). This reduction is primarily due to instability and buckling rather than material failure.
Predictive Accuracy
The proposed simplified formula demonstrated high accuracy when compared to experimental results, with errors ranging from 0.87% for axial loads to approximately 5.21% for biaxial bending. This validates the formula as a reliable tool for practical structural design.
Conclusion
L-shaped SCFT columns offer a robust and space-efficient alternative to traditional column designs. While eccentric loading significantly impacts their bearing capacity, the predictable nature of their failure and the accuracy of the proposed design formulas make them a viable option for high-performance residential structures. Future research will focus on long-term effects such as creep and fire performance to further refine the design guidelines.
Summary updated