Who Got the FISH Test? Auditing Verification Bias in Retrospective HER2 Prediction

Hospitals keep large archives of routine tissue slides, and machine-learning models are now trained on those archives to predict a tumor's genetic status, for example whether the HER2 gene is amplified in breast cancer. The label these models learn from usually comes from fluorescence in situ hybridization (FISH). FISH is a lab test in which glowing DNA probes stick to a specific gene, so a pathologist can count its copies inside each cell nucleus. FISH is expensive, and doctors do not order it at random. They order it mostly when the cheaper protein stain is ambiguous, or when something else about the case worries them.

As a result, the patients in a retrospective cohort (a study built backward from existing hospital records) who have a FISH result differ systematically from those who do not. Any accuracy number computed on "cases with FISH available" describes that selected group, not the patients the model would actually screen. Epidemiologists call this verification bias. This note proposes to measure how large the bias is for HER2 prediction from slide images, and to test which statistical corrections remove it. The test uses something retrospective studies almost never have: a small, randomly chosen audit sample of archived tissue blocks that receive FISH after the fact, whatever their original test history.

Core Claim

Published accuracy figures for image-based HER2 prediction come from cohorts filtered by clinical testing decisions. The HEROHE challenge (HEROHE Challenge: predicting HER2 status…) is one example. It deliberately enriched its data for equivocal (IHC 2+) cases, inflated the share of positive cases, and excluded tumors with mixed HER2 status. The GrayMap+CNN study (Using Whole Slide Gray Value Map to Predict HER2 Expression and FISH Status in Breast Cancer) is another: it kept only the 228 cases with complete IHC and FISH results.

We claim three things. First, these filtered figures can be biased by an amount that matters clinically in the full population of biopsied patients. Second, the bias depends on what drove FISH ordering, and the protein-stain score may not be the only driver. Third, standard inverse-probability weighting, which reweights each tested case by how likely it was to be tested, can recover the population figures, but only when the model of who gets tested includes the true drivers. The audit sample is what makes these claims checkable rather than assumed.

The new part is not the correction method. Weighting by the probability of receiving an intervention is routine in outcome studies. Tewari et al. used propensity matching to balance surgery and conservative arms in prostate cancer (Evaluating Clinical Outcomes Using Historical Patient Cohorts). What is new is treating the FISH test itself as the non-randomly assigned exposure in a diagnostic-AI evaluation, and validating the correction against ground truth that the field currently lacks.

Why this gap is real

The research file contains direct evidence that molecular testing in real-world cohorts follows clinical judgment. In 21,991 National Cancer Database patients with intermediate 21-gene scores, Chen et al. found that chemotherapy decisions tracked age, grade and tumor size more than genomic risk (Practice patterns and outcomes…). For example, the adjusted odds ratio for patients over 80 versus under 40 was 0.07. This paper motivates the proposal: it shows that clinicians' downstream decisions are driven by non-genomic features. It does not show the same for test ordering, which is exactly what we will estimate.

FISH-based retrospective studies routinely run analyses only on the patients with complete results. Lim et al.'s neuroblastoma cohort is a typical case: it profiled 173 of 212 patients and did not model why the remaining patients lacked complete cytogenetics (Clinical Significance of Segmental Chromosomal Aberrations in Patients with Neuroblastoma). The FISH image-analysis models YOLO-SEM (Deep learning method for detecting fluorescence spots…) and SEAM-Unet++ (An Improved Nested U-Net Network for FISH Cell Image Segmentation) automate the FISH reading itself. They report only image metrics on small single-center sets. We use them as tools, not targets: they make audit FISH reading cheap and consistent. Propensity Score Alignment (Propensity Score Alignment of Unpaired Multimodal Data) uses propensity scores to pair unpaired data types. Our use is different and simpler. The score estimates who was tested, not which samples correspond.

Research Program

We will assemble a retrospective cohort from one or more pathology archives. It will include every invasive breast biopsy over a fixed period, with the H&E slide, the IHC score, and whatever FISH result exists. It will also include candidate drivers of FISH ordering: age, grade, tumor size, center, year, ordering pathologist, and insurance or referral source where available.

Let $V=1$ indicate that a case received clinical FISH. Let $\pi(x)=P(V=1\mid X=x)$ be the probability of testing given covariates $X$. Let $D$ be true amplification status and $T$ be the model's positive call. The weighted sensitivity estimate is

$$\widehat{\text{Sens}}=\frac{\sum_i V_i T_i D_i/\hat\pi(x_i)}{\sum_i V_i D_i/\hat\pi(x_i)},$$

with specificity, AUC and calibration weighted the same way. This estimator is unbiased only if testing depends on nothing beyond $X$, an assumption the audit sample is designed to test.

The audit draws a stratified random sample of archived blocks that never received FISH, from IHC 0, 1+ and 3+, plus heterogeneous tumors. Clinical labels in those strata are currently inferred from IHC alone. Each audit block receives FISH, read by two blinded cytogeneticists. YOLO-SEM-style spot counting serves as a third reader to flag disagreements. The audit yields design-based population estimates of the model's accuracy that require no assumption about why clinicians ordered tests. All corrections are compared against these estimates.

Two prediction models will be evaluated. One is an H&E multiple-instance model trained in the HEROHE style. The other is a reimplementation of the GrayMap+CNN pipeline on IHC slides. Each is trained twice: unweighted, and with the training loss reweighted by $1/\hat\pi$. This separates bias in evaluation from bias in training.

Baselines

The naive reference point is complete-case evaluation. It reports accuracy, F1 and AUC on cases that have clinical FISH, which is how HEROHE and GrayMap+CNN report results. Its deviation from the audit estimate is the quantity we are measuring.

The strongest existing methods supply the image-model numbers. HEROHE reports an overall test F1 of 0.68 and an equivocal-subset F1 of 0.79 (Team Macaroon), and an equivocal-subset AUC of 0.88 (Team Arontier_HYY) (HEROHE Challenge: assessing HER2 status…). GrayMap+CNN reports FISH-status accuracy of 0.921 ± 0.029 under five-fold cross-validation. We will reproduce these models on our archive with the same tuning budget and splits. We expect complete-case figures roughly in this range, which would confirm faithful reimplementation before any correction is applied.

The strongest competing correction is IHC-stratified reweighting. This reweights FISH-tested cases so that the IHC-score distribution matches the full cohort. It is the obvious alternative and is correct if IHC is the only driver of testing. A third correction imputes the missing FISH labels from IHC and covariates.

Our full-covariate weighting counts as beating these alternatives if its estimates fall closer to the audit estimates for sensitivity, specificity and calibration slope, by more than the audit's own bootstrap interval. The key ablation drops covariates one at a time from $\hat\pi$ to identify which drivers matter. A second ablation compares weighted and unweighted training, to show whether correcting evaluation is enough or training must change too.

Why not just…?

Why not just trust held-out test sets like HEROHE's? HEROHE's own design rules this out as a population estimate. It enriched for IHC 2+ cases, inflated prevalence, and excluded heterogeneous tumors, and the reported F1 rises from 0.68 overall to 0.79 on the 2+ subset. So performance clearly depends on case mix. A held-out split of a selected cohort inherits the same selection. The audit comparison will measure the gap directly.

Why not just reweight by IHC score? This is a real threat. If guidelines dictate FISH strictly for IHC 2+ cases, IHC-stratified reweighting is essentially the full correction, and our richer propensity model adds nothing. The experiment settles the question. If IHC-only and full-covariate weighting agree with each other and with the audit, we will report that simple stratification is sufficient. That is itself useful and currently unestablished. Our hypothesis is that ordering outside guidelines in the 0/1+/3+ strata, and differences between centers and eras, are large enough to separate the two.

Why not just impute missing FISH labels from IHC? Imputation assumes the same thing weighting does, namely that testing depends only on recorded variables. It also builds in the clinical convention that IHC 0/1+ means non-amplified. That convention is exactly what the audit FISH of 3+ and heterogeneous blocks checks. Imputation is included as a baseline, so its failure or success will be visible.

Why not just FISH every archived case? This would be ideal, but it is costly, and it uses up tissue that may be depleted. The audit is a deliberately small version of the same idea. A key output is how large an audit must be for the corrected estimates to be trustworthy, which tells future studies how much verification to buy.

Proposed Experiments

The first decisive check is the size of the bias. We compare complete-case, IHC-reweighted, imputed and full-covariate-weighted estimates of sensitivity, specificity, AUC and expected calibration error against the audit-based estimates, with bootstrap intervals that account for the stratified audit design.

The second check is whether the assumption behind weighting holds. We test whether audit-confirmed amplification rates within IHC strata vary with covariates that predict testing. Such variation would mean testing depends on factors linked to the true label, beyond what $X$ captures.

The third check tests whether training on a selected cohort harms models beyond what evaluation correction can fix. We compare weighted and unweighted training, evaluated on the audit. If unweighted models are worse on the audit even after correcting their evaluation, then the selection bias has entered the models themselves.

A secondary, exploratory analysis links audit-revealed discordant cases, such as IHC 0/1+ tumors that are FISH-amplified, to the anti-HER2 therapy and outcome records in the archive. This indicates whether the corrected error rates correspond to patients who missed treatment. No reported result was found on Lacuna for verification-corrected HER2 prediction accuracy, so every corrected figure will be new.