Haruhiko Kishima

1 previous affiliation
561Machine learning papers tracked by Lacuna
Is this you?

Research Overview

Haruhiko Kishima focuses on functional neurosurgery, neuro-oncology, and the development of advanced neural interfaces. His work integrates clinical neurosurgical practice with engineering and computational neuroscience to address refractory neurological conditions, including malignant gliomas, epilepsy, and movement disorders. His research trajectory has evolved from early investigations into gene therapy for brain tumors toward the development of sophisticated brain-machine interfaces (BMIs) and the implementation of Limitations of Open Loop Neuromodulation. Currently, his work emphasizes the application of artificial intelligence to neuroimaging, the refinement of sensory feedback in neural prosthetics, and the advancement of minimally invasive surgical techniques.

Research Trajectory

The early phase of this research, beginning in the mid-1990s, was primarily concerned with the biological barriers to treating malignant gliomas. A significant focus was placed on the viability of retroviral gene transfer within the central nervous system. This work addressed the challenge of complement-mediated inactivation of retroviruses in human serum, demonstrating that cerebrospinal fluid and the tumor bed environment in glioma patients do not possess the same inhibitory properties as systemic circulation. These findings provided a rationale for direct intracranial delivery of therapeutic vectors to circumvent systemic immune barriers.

By the early 2010s, the research program expanded into functional restoration and sensory prosthetics. This period involved participation in clinical trials for retinal prostheses, specifically the suprachoroidal-transretinal stimulation (STS) system. This work aimed to restore visual function in patients with advanced retinitis pigmentosa by leveraging non-contact electrical stimulation of the retina, evaluating both the safety and functional efficacy of chronic implants.

The late 2010s marked a transition toward the analysis of complex neural networks and the development of BMIs. This shift involved moving beyond the study of isolated brain regions to a more holistic understanding of neural dynamics, facilitated by advanced imaging and mathematical modeling. This era focused on Spatial Field Steering and Somatotopic Mapping to provide precise sensory feedback and the decoding of specific motor and physiological intentions, such as swallowing, from intracranial signals. This work addressed the The Offline to Online Translation Gap in Neural Interfaces by refining the accuracy of real-time decoders.

In the current decade, the research has increasingly integrated artificial intelligence and real-time feedback systems. This includes the development of Adaptive Stimulation Driven by Real Time Biomarkers and Volitional Control of Brain Activity through Real-Time Feedback. Furthermore, the work has advanced surgical techniques through the adoption of high-definition exoscopic systems and the exploration of microendovascular neural recording, which aims to provide high-precision, minimally invasive access to cortical activity.

Current Directions

Current research efforts are concentrated on three primary areas: the optimization of BMIs, the application of AI in neuro-oncology, and the refinement of vascular neurosurgery protocols. In the domain of BMIs, the focus is on establishing quantitative relationships between cortical stimulation and perceived sensation to calibrate artificial sensory feedback. This is complemented by work on deep learning-based decoders that can interpret complex intracranial signals for functional restoration.

In neuro-oncology, the research utilizes AI for automatic lesion extraction and tumor volume measurement, particularly for meningiomas. This work aims to establish objective, highly reproducible evaluation indices for tumors characterized by slow growth. Additionally, the use of advanced MRI mapping, such as T1w/T2w-ratio maps, is being investigated to visualize non-enhancing tumor lesions in glioblastoma, which are often difficult to detect with standard imaging protocols.

The vascular neurosurgery component of the current research focuses on improving safety and ergonomics during delicate procedures. This includes evaluating the transition from traditional surgical microscopes to 4K 3D exoscopic systems for aneurysm clipping. Furthermore, the research investigates hemodynamic predictors of ischemic tolerance during carotid artery procedures, aiming to refine diagnostic protocols and improve patient outcomes.

Representative Work

Infectious Retrovirus Is Inactivated by Serum but Not by Cerebrospinal Fluid or Fluid from Tumor Bed in Patients with Malignant Glioma This early study investigated the limitations of retroviral gene transfer for treating malignant gliomas. The research identified that while human serum severely inactivates amphotropic retroviruses through complement-mediated proteolysis, the cerebrospinal fluid and the fluid within the tumor bed do not exhibit this effect. These results suggested that direct intracranial injection of retrovirus-producing cells or viral supernatants is a viable strategy for gene therapy, as the local environment of the brain preserves viral infectivity.

Clinical Trial of Chronic Implantation of Suprachoroidal-Transretinal Stimulation System for Retinal Prosthesis This work details a clinical trial of a "non-contact" retinal prosthesis system. The study involved the chronic implantation of a suprachoroidal-transretinal stimulation (STS) system in patients with advanced retinitis pigmentosa. The research evaluated the safety and functional efficacy of the system over several weeks, contributing to the development of visual prosthetics that avoid direct contact with the delicate retinal surface.

Somatosensation Evoked by Cortical Surface Stimulation of the Human Primary Somatosensory Cortex This study demonstrated a linear relationship between the intensity of electrical stimulation applied to the primary somatosensory cortex and the intensity of the resulting artificial sensations. By utilizing electrocorticography (ECoG) surface electrodes in clinical patients, the research provided a quantitative framework for calibrating sensory feedback. This calibration is essential for the development of BMIs that can provide realistic and controllable tactile sensations to users.

A Swallowing Decoder Based on Deep Transfer Learning: AlexNet Classification of the Intracranial Electrocorticogram This research addressed the development of functional BMIs for patients with severe swallowing disorders. By applying deep transfer learning to intracranial ECoG signals, the study demonstrated the ability to decode swallowing intentions with high precision. The use of established image-recognition architectures to process neural signals represents a methodological shift in how complex motor intentions are classified in real-time systems.

Ophthalmic Artery Flow Pattern-related Stump Pressure and Ischemic Tolerance during Balloon Test Occlusion of the Internal Carotid Artery As senior author, Kishima led this investigation into hemodynamic predictors for the permanent closure of the internal carotid artery. The study found that the direction of blood flow in the ophthalmic artery during temporary balloon occlusion serves as a reliable indicator of ischemic tolerance. Specifically, the absence of "backward" flow into the brain was associated with 100% tolerance, providing a rapid diagnostic tool to enhance the safety of vascular neurosurgical interventions.

Exoscopic Keyhole Clipping of Unruptured Middle Cerebral Artery Aneurysms Using Multiple 4K 3-dimensional Monitors In this senior-authored study, the research evaluated the use of a high-definition 4K 3D exoscope system for the surgical treatment of brain aneurysms. The study demonstrated that exoscopic "keyhole" surgery is a safe and effective alternative to traditional microscopic surgery. The findings highlighted significant ergonomic advantages for the surgical team and the benefits of high-resolution visualization in performing delicate neurovascular procedures.

Profile updated

See something wrong? Report a mistake