A thin layer of liquid between a foot and the ground does two useful things at once. Each tiny liquid bridge pulls the surfaces together through surface tension, which gives adhesion. As the foot slides, the edge of each bridge alternately sticks and jumps, which damps the motion. A footpad covered with many such bridges, joined through a soft backing, behaves like a collection of coupled stick-slip elements. Collections like this have a transition point. With very weak pinning the pad creeps smoothly and gives way. With strong, uniform pinning it holds firmly and then lets go all at once. Between these two regimes, slip happens in bursts of every size, and the burst sizes follow a power law, the statistical signature of a critical point. We propose that this transition is the right coordinate for the trade-off every legged and climbing robot faces between robustness (resisting slips and shocks) and efficiency (not paying energy to peel the foot off every step). Evaporation moves the pad along this coordinate, so it is both a nuisance and a usable control knob.
The concrete claim is that a capillary-array footpad gives its best robustness-for-energy compromise near the slip transition. A second claim is that the burst statistics of the pad's own friction-force signal reveal how far the pad is from that point. This signal is cheap and needs no task model, so a controller can use it to meter liquid onto the pad as humidity and evaporation drift. If the claim holds, a robot can use a liquid-mediated foot in changing environments without recalibrating it for each condition. If it fails, the experiment shows cleanly whether simpler observables such as mean adhesion force are enough.
What Exists and What Is Missing
On the capillary side, the closest physics is Noncontact friction via capillary shear interaction at nanoscale. That study measured a single water bridge between an atomic force microscope tip and mica. It found that contact-line pinning and depinning produces damping that grows only logarithmically with sliding speed and rises tenfold, with stiffness rising fivefold, as relative humidity goes from 2% to 60%. We take two things from it: the single-bridge damping law for our simulation, and the warning that humidity shifts the operating point strongly. We differ in studying many coupled bridges on a moving foot rather than one bridge on a fixed probe. Fabrication work such as Fukushima et al. shows that a shrinking, evaporating meniscus pulls parts into intimate contact. That work treats evaporation as a one-way bonding step that ends in a permanent bond. We treat partial evaporation as a reversible state variable and prevent full dry-out by replenishing liquid. The microcone fabrication in Magnetic soft millirobot with simultaneous locomotion and sensing capability supplies a ready pad geometry and a small inchworm testbed. That robot reaches 1.4 mm/s and carries 5.2 times its own weight, but its cones are cured dry.
On the criticality side, our method comes directly from Signatures of criticality in efficient coding networks. In a spiking network, that paper found that the noise level minimizing reconstruction error coincides with the level where avalanche sizes best fit a power law, measured by a deviation statistic $\kappa$ that is zero for a perfect power law. We ask the same alignment question for a physical contact and a mechanical objective. Task-adaptive physical reservoir computing provides a precedent for using a material's phase as a tuning knob: moving a chiral magnet between phases trades memory for nonlinearity. Our knob is liquid volume, and our objective is mechanical rather than computational.
On the trade-off side, Viability leads to the emergence of gait transitions gives the clearest quantitative statement that robustness costs energy. Their quadruped switches from trot to pronk over gaps, raising its cost of transport from 0.84 to 0.93. Foot-level hardware tackles the problem with bulky switching. The jamming foot in Fast state-switching of a jamming-based foot needs a 50 ml syringe and a solenoid to reach -180 mbar in 62.2 ms. The pneumatic climber in Switchable Adhesion Actuator for Amphibious Climbing Soft Robot reaches 6–8 N dry and 10.62 N underwater. Neither offers a passive interface with a measurable distance from instability.
The obvious idea at this intersection is to turn the wet pad into a physical reservoir computer, a physical system whose rich dynamics are read out to perform computation, in the spirit of From Digital to Physical Reservoir Computing and The role of feedback in morphological computation with compliant bodies. We deliberately do not do this. A digital recurrent network on a microcontroller would almost certainly outcompute a handful of droplets, and the computing claim would be hard to defend. Criticality matters here because it organizes a mechanical trade-off and supplies a cheap diagnostic, not because it provides computing power.
Core Claim
Let $V$ be the liquid volume per bridge, normalized by the cone tip area. Let $\kappa(V)$ be the deviation of the slip-burst size distribution from a fitted power law. For each step we measure two quantities: the detachment work $W_d$, the energy spent lifting the foot off, and the slip $s$, the lateral displacement under a standardized sideways impulse. We define the trade-off score
$$J(V) = W_d(V) + \beta\, s(V),$$
where $\beta$ converts slip into an energy-equivalent penalty. We sweep $\beta$ to trace the full Pareto front between peel cost and slip.
The prediction is that the knee of the Pareto front sits at the $V$ that minimizes $\kappa$, and that this alignment persists when humidity shifts both curves. The intuition is as follows. On the strongly pinned side, large system-spanning releases make the pad brittle: it holds, then fails completely. On the weakly pinned side, the pad creeps and dissipates energy without arresting the slide. At the transition, bursts of all sizes absorb a perturbation locally without either cost.
Research Program
The first stage is a simulation. Each cone carries a liquid bridge whose adhesion depends on $V$ and whose contact line follows the pinning-depinning law with logarithmic velocity damping measured by Lee et al. The bridges are coupled through an elastic backing of tunable stiffness, and pinning thresholds are disordered across cones. We sweep volume, backing stiffness, and threshold disorder. For each setting we measure $\kappa$, the largest Lyapunov exponent of the driven pad (the exponential rate at which nearby trajectories separate, zero at the boundary between order and chaos), $W_d$, and $s$. The simulation must first show that a transition exists at all. It must also show where the transition sits relative to the Pareto knee, before any hardware is built.
The second stage is hardware. We mold or jet-print elastomer microcone pads following the Zeng et al. process. We wet them with water and with a glycerol-water mixture, which evaporates more slowly and so separates the effect of evaporation rate from that of bridge volume. Tests run on a single-leg drop-and-drag rig modeled on the Hauser et al. treadmill setup, inside a humidity chamber spanning roughly 20–70% relative humidity. A six-axis force sensor sampled at several kilohertz records tangential force. Slip bursts are segmented as drops in tangential force, and $\kappa$ is computed over windows of a few steps.
The third stage is control. A micro-wicking channel meters liquid into the pad. A regulator adjusts the dosing rate to hold $\kappa$ near its minimum. We test this regulator on a small inchworm or climbing robot during humidity ramps and on wet and dry substrates.
Baselines
The naive reference is the same microcone pad left dry and cured, as in Zeng et al. It shows what liquid adds at all. We run it on the identical rig, robot, substrates, and humidity schedule. The proposal must beat it on slip without more than marginally increasing detachment work.
The fixed-volume pad is the strongest passive competitor. It is wetted once at the volume found optimal by an offline grid search at 40% relative humidity, then left alone. It receives the same grid-search budget as our calibration. Beating it means a lower score $J$ when humidity moves away from the calibration point.
The strongest simple active competitor is a mean-force regulator. It uses the same dosing hardware but holds the rolling mean pull-off force at its calibrated optimum instead of holding $\kappa$. Its sensor, dosing actuator, window length, and tuning budget are identical to ours. This baseline is the real test of the criticality claim. The $\kappa$ regulator must achieve lower $J$ across the humidity ramp with overlapping or better variance. Matching it is not enough.
For dry switchable adhesion, we reimplement a jamming foot after Hauser et al. and a positive-to-negative pneumatic pad after Tang et al. at the same footprint. We report the published reference figures: 62.2 ms to reach -180 mbar for the jamming foot, and 6–8 N dry and 10.62 N underwater adhesion for the pneumatic pad. We compare on slip, detachment work, and the added mass and power of the switching hardware, which our pad mostly avoids. No result on Lacuna reports detachment work or impulse slip for a capillary-array footpad, so these measurements establish the first reference.
The key ablation decouples the bridges by cutting the backing into isolated posts. This removes the collective transition while keeping per-bridge physics. If the decoupled pad matches the coupled one, criticality is not doing the work.
Why not just…?
Why not just grid-search the liquid volume for each condition and skip criticality? Offline, this is a real threat, and in a fixed environment it may well be all one needs. The argument for $\kappa$ applies only to online use: it can be read from the force signal during normal walking without running the lateral-impulse test that defines $s$. The humidity-ramp experiment settles this. If a per-condition lookup table indexed by a cheap humidity sensor matches the $\kappa$ regulator, we will report that the transition explains the trade-off but is not needed to control it.
Why not just use a jamming or pneumatic switchable foot? These already handle the stiffness trade-off well at the macroscale. However, the jamming foot carries a syringe and solenoid, and the pneumatic pad needs chambers and pressure lines. These overheads are prohibitive at the millirobot scale, where Zeng et al.'s robot weighs a few tenths of a gram. Dry pads also behave differently on wet surfaces. Our head-to-head at equal footprint reports performance per unit of added mass and power, which is where we expect the advantage. If the reimplemented jamming foot still wins at that scale, the comparison will show it.
Why not run a small digital recurrent network on the force signal to predict slips and trigger a response? A learned slip predictor is plausible and cheap, and the recent work in Global Credit Assignment via Dynamical Criticality makes training such networks online less memory-hungry. It still needs a fast actuator to act on its predictions, and a passive pad has none. The question we ask is where to set the passive interface, not how to react after it slips. These approaches are complementary. We will include a learned-predictor-plus-dosing variant as a secondary comparison to check that $\kappa$ is not simply a weaker version of the same information.
Decisive Checks
The first check is in simulation. Coupled pads must show a $\kappa$ minimum and a Lyapunov exponent crossing zero at the same volume. Decoupled pads must show neither. Without this result we stop before building hardware.
The second check is on hardware, at three or more humidity levels. The volume minimizing $\kappa$ must fall within the measurement uncertainty of the Pareto knee of $W_d$ against $s$. This mirrors the error-and-$\kappa$ alignment test of Signatures of criticality, applied to a mechanical objective.
The third check is on the robot during humidity ramps. The $\kappa$ regulator must beat both the fixed-volume pad and the mean-force regulator on $J$. On the inchworm platform we also report a robot-level cost of transport, the energy spent per unit weight per unit distance. A positive answer on all three checks would establish the slip transition as a usable design and control coordinate for liquid-mediated feet. A negative answer on the third check alone would still yield a mechanistic account of why wet pads trade robustness for efficiency.
References
- Noncontact friction via capillary shear interaction at nanoscale
- Self-Assembled 3D Chip Stacking Technology - an Invited Talk
- Magnetic soft millirobot with simultaneous locomotion and sensing capability
- Signatures of criticality in efficient coding networks
- Task-adaptive physical reservoir computing
- Viability leads to the emergence of gait transitions in learning agile quadrupedal locomotion on challenging terrains
- Fast state-switching of a jamming-based foot
- Switchable Adhesion Actuator for Amphibious Climbing Soft Robot
- From Digital to Physical Reservoir Computing: Co-Optimizing Soft Robotic Reservoirs via Dynamics Matching
- The role of feedback in morphological computation with compliant bodies
- Global Credit Assignment via Dynamical Criticality