Separating Tissue Thickness from Perfusion in Thermal Aging Clocks

A thermal camera sees the face as a map of heat. That heat comes from blood flowing just beneath the skin, which makes thermal imaging attractive for measuring vascular aging without needles or clinical scanners. The catch is a problem engineers know well from insulation design. A cool, slowly rewarming patch of skin can mean two things. It can mean the blood vessels are responding poorly, which is the aging signal we want. Or it can mean a thicker layer of fat sits between the blood supply and the surface, acting as insulation. A single thermal snapshot cannot tell these apart, so any age model trained on still thermal images risks learning body composition and calling it age.

We propose a short, standardized cooling-and-rewarming test recorded with a long-wave infrared camera. The rewarming curves are fit with a two-layer heat-transfer model of skin, giving two numbers per facial region: an effective insulating thickness and a perfusion response. The core bet is physical. Layer thickness and perfusion leave different fingerprints in time, even when they leave the same fingerprint in a single frame, so the transient response can separate them. We then build the aging clock only on the perfusion and recovery parameters, with thickness treated as a nuisance variable to measure and set aside. This turns the "optimal layer thickness" reasoning used to design heat spreaders and insulation into a tool for removing the effect of thickness from a physiological biomarker.

Core Claim

Static thermal age models confound adiposity with vascular decline. A model that infers tissue thickness and perfusion separately from rewarming kinetics should do two things. It should predict vascular-health markers better than static thermal or visible-light face models. It should also stay accurate when people of similar age differ sharply in subcutaneous fat. What would be new is the inference step, not the camera: recovering a geometric quantity (layer thickness) and a physiological quantity (perfusion) from surface temperature over time, then building an age estimate on the physiological part alone.

The physics follows the bioheat model already used in thermal ablation planning (Coupled electrical-thermal model for RF liver ablation couples it to electromagnetics to size lesions; we use it non-destructively):

$$\rho c\,\frac{\partial T}{\partial t} = k\,\nabla^2 T + \omega\,\rho_b c_b\,(T_a - T) + q_m,$$

Here $T$ is tissue temperature, $\rho c$ and $k$ are the tissue's volumetric heat capacity and conductivity, $\omega$ is the perfusion rate, $\rho_b c_b$ is the heat capacity of blood, $T_a$ is arterial temperature, and $q_m$ is metabolic heat.

In a fat layer of thickness $L$ over perfused dermis, steady surface temperature depends roughly on the combination of $L/k_{\text{fat}}$ and $\omega$. This is the flat-layer resistance $R=t/k$ that sets optimum insulation thickness in Lifecycle Cost Analysis of An Insulated Duct With An Air Gap. After a perturbation, however, the surface response has two separable timescales:

$$\tau_{\text{cond}} \sim \frac{L^2}{\alpha_{\text{fat}}}, \qquad \tau_{\text{perf}} \sim \frac{\rho c}{\omega\,\rho_b c_b}.$$

Here $\alpha_{\text{fat}}$ is the thermal diffusivity of fat. The first timescale comes from diffusion through a slab. The second comes from the relaxation rate of the perfusion term in the bioheat equation. Thickness enters squared in one and not at all in the other, which is the source of identifiability.

The analogy to Graphite plates for thermoelectric generators shapes the model design rather than supplying a result. That study found a 2 mm optimum because one geometric parameter controlled two opposing heat paths: lateral spreading and through-plane resistance. Perfused dermis spreading heat sideways beneath an insulating fat layer is structurally similar. Whether facial tissue actually behaves non-monotonically is a hypothesis we test, not an assumption.

Research Program

The work has four stages.

Stage 1: identifiability in simulation. We simulate two-layer, laterally heterogeneous skin under the proposed cooling protocol and ask when $(L, \omega)$ can be recovered from surface temperature at realistic camera noise and frame rates. We will also identify which protocol (cooling duration and depth) maximizes separability. This is the protocol's own "optimal thickness" problem.

Stage 2: phantom validation. We fabricate layered silicone phantoms with known insulating-layer thicknesses and embedded heated flow channels at controlled flow rates. Because ground truth is fully known, inference error can be measured exactly.

Stage 3: human pilot. We reuse recovery-kinetics modeling on the post-exercise thermal sequences of Estimating exercise-induced fatigue from thermal facial images. That work imposed a linear five-minute decay on every subject and acknowledged that individuals recover differently. We fit per-subject physical recovery curves instead and check that the fitted parameters are stable across repeated sessions.

Stage 4: aging cohort. We collect a cohort spanning adulthood (we target several hundred participants aged 20–80). Each participant receives:

  • synchronized thermal and visible video during a mild facial or hand cooling challenge;
  • ultrasound measurement of subcutaneous fat thickness at matched sites, as ground truth for $L$;
  • body mass index;
  • blood pressure and pulse-wave measures;
  • a comorbidity index of the kind used by the multimodal retinal aging clock;
  • a wrist PPG recording.

The clock follows the healthy-reference design of PpgAge. We fit a regression from regional perfusion and recovery parameters to chronological age in a screened healthy subgroup, then read the residual as age acceleration. Aware of the argument in Is age an independent determinant of mortality in cardiac surgery that calendar age stands in for measured deterioration, we also fit a version trained directly on the vascular and comorbidity outcomes.

Recovery kinetics, rather than static state, are the target for a stated reason. The Gompertz Law emerges naturally from inter-dependencies between sub-components frames aging as loss of resilience across interdependent subsystems. This motivates measuring recovery from a perturbation, though it supplies no empirical evidence for thermal markers specifically. Organ-specific clocks such as Imaging-based organ-specific aging clock show that targeted subsystem clocks predict matched diseases. We therefore position our measure as a peripheral microvascular clock, not a whole-body one.

Baselines

Naive reference. The do-nothing reference is chronological age, together with chronological age plus body mass index, used to predict the vascular and comorbidity endpoints. Any proposed age gap must add information beyond these. Beating it means a statistically significant gain in explained variance for blood pressure and pulse-wave measures, and in discrimination of hypertension and comorbidity, under cross-validation.

Strongest existing face-based clock. This is FaceAge (Decoding biological age from face photographs), a face-recognition network fine-tuned to regress age from photographs. It reported a survival hazard ratio of 1.15 per decade of acceleration in a thoracic cancer cohort and raised clinician survival AUC from 0.74 to 0.80. We run the released approach on the visible frames captured simultaneously with our thermal recordings, from the same participants, with no retraining beyond whatever recalibration we also allow our model. Beating it means a higher association with vascular endpoints and a smaller dependence on body fat, measured as the partial correlation of each age gap with ultrasound fat thickness at fixed age.

Strongest wearable clock. PpgAge reported a healthy-cohort error of about 2.4 years and a hazard ratio of 1.464 for incident heart disease per six-year gap. We cannot reproduce its foundation model, so we implement a PPG-morphology regression on our own wrist recordings under the same healthy-reference protocol. We will report this as an approximation, not as PpgAge itself. MotionAge (MotionAge) reports a C-index of 0.848 for five-year mortality on the National Health and Nutrition Examination Survey (NHANES). Our cohort will lack mortality follow-up, so that number cannot be compared directly, and we say so.

Black-box thermal model. This is a ResNet-50 on single thermal frames, in the style of Lage Cañellas et al., who report a mean absolute error of 13.64% for fatigue on their own dataset. No reported result was found on Lacuna for thermal facial age estimation. We also train a recurrent sequence model on the full rewarming video. Both get the same data, splits, and hyperparameter search budget as our model.

Key ablations. First, we replace the two-layer physical model with a single homogeneous layer. Second, we keep the two-layer fit but feed the clock both $L$ and $\omega$. If the second variant beats the perfusion-only clock on age prediction but loses on the fat-independence test, it confirms that thickness carries a body-composition shortcut.

Why not just…?

Why not just train a CNN on raw thermal images? This is the obvious first paper at this intersection, and it may predict chronological age reasonably well. Our concern is what it predicts with. Body fat changes with age, so a static model can lower its age error by reading insulation. The fat-independence test settles this. If the static CNN's age gap shows no residual correlation with ultrasound fat thickness at fixed age, and it matches our vascular associations, the physics is unnecessary and we will report that.

Why not just a sequence model on the rewarming video, without physics? This is the real threat. A flexible model sees the same temporal information our fit does and could learn the separation implicitly. Our advantage should appear in two places: smaller cohorts, and transfer across sites or cameras, because two physically meaningful parameters per region are hard to overfit. We test both with learning curves and a held-out acquisition site. If the black-box sequence model matches us in both settings, our contribution narrows to interpretability and phantom-verified measurement. That still has value, but it is a smaller claim.

Why not just adjust for body mass index? Body mass index is a crude, whole-body proxy for local facial fat, and fat distribution differs by sex and age. We compare three variants: regressing body mass index out of a static thermal clock, regressing ultrasound fat thickness out of it, and our inferred-thickness approach. If adjusting for body mass index closes the gap, the cheaper method wins.

Why not just use FaceAge or a smartwatch? Both are cheaper and validated. However, FaceAge reads surface reflectance and is open to cosmetic and lighting confounds. PPG measures one wrist site and is shifted by acute states; PpgAge itself rose by a median of 3.5 years during pregnancy. We do not claim to replace them. We test whether the thermal recovery gap adds information when combined with them, in nested models.

Proposed Experiments

Simulation and phantoms. The first decisive check runs on phantoms, where the target is recovery of insulating thickness and flow rate within the tolerances that matter physiologically. If thickness and perfusion cannot be separated even in silicone, the human program stops there.

Measurement validity. We check whether inferred $L$ correlates with ultrasound fat thickness in humans, and whether inferred $\omega$ is repeatable across sessions on the exercise dataset and in our cohort.

Fat independence. The central test is whether the perfusion-based age gap stays associated with blood pressure, pulse-wave measures, and comorbidity after conditioning on measured fat thickness. Alongside it, we check whether the static-CNN and FaceAge gaps lose association under the same conditioning.

Robustness. We evaluate performance with eyeglasses, since both ARL-VTF and the fatigue study identify eyewear as a major failure source. We also evaluate under ambient-temperature variation. A region-wise physical fit should degrade gracefully, because it can drop occluded regions instead of misreading them.

What would falsify the idea. The idea fails if the black-box sequence model, given equal budget, matches us on the fat-independence test and on cross-site transfer. It also fails if adjusting for body mass index makes the static thermal clock as fat-independent as ours. Either outcome would mean the explicit separation of thickness and perfusion is not earning its cost.