Separating Scan Misalignment from Reader Disagreement in Few-Case Multi-Contrast Segmentation

When several radiologists outline the same tumor and their outlines disagree, current methods treat all of that disagreement as human subjectivity. In multi-contrast imaging, where a patient is scanned several times with different MRI settings, some of the disagreement has a physical cause. The patient moves between scans, so a reader tracing the border on the second scan lands a few millimetres away from a reader tracing on the first, even if both see the same anatomy. We propose a segmentation model that learns two separate things. The first is a smooth physical shift between the scans, shared by every reader who traced on a given scan. The second is a per-reader "style" that captures genuine judgment differences. The shift is constrained to be spatially smooth and common to all readers on a scan, while reader style cannot be. This structural constraint makes the two separable, and it acts as the kind of strong prior that small datasets need.

This matters most when labeled cases are scarce. A model trained on ten or twenty cases with several readers each has little data to spend. If it must learn misregistration as though it were reader idiosyncrasy, it wastes capacity on per-reader decoders that each memorize a different spatial offset. It also reports inflated uncertainty precisely at the borders clinicians care about. The cleaner the separation, the more honest the uncertainty map and the less data the reader-style part needs.

Core Claim

The observed disagreement among readers' masks on multi-contrast scans can be modeled as a reader-style distribution defined in one reference scan's coordinates, then moved by a per-case displacement field into the coordinates of the scan each reader actually viewed. Writing $x$ for the stack of co-acquired scans, $c$ for the scan a reader traced on, $z_r$ for a low-dimensional latent describing reader $r$'s style, $f$ for the segmentation network, and $\phi_c(x)$ for a smooth displacement field predicted from the images, the likelihood of reader $r$'s mask $Y_{r}$ is

$$ p(Y_r \mid x) = \int p\big(Y_r \mid f(x, z_r) \circ \phi_{c(r)}(x)\big)\, p(z_r)\, dz_r , $$

trained with a smoothness penalty on $\phi$ and with $\phi_{\text{ref}}$ fixed to the identity. Here $f(x,z_r)\circ\phi$ means the predicted mask resampled through the displacement. The field is applied to the predicted mask, never to the image intensities. This is deliberate. Volumetric Conditional Score-based Residual Diffusion Model for PET/MR Denoising and Multi-Contrast MRI Super-Resolution via a Multi-Stage Integration Network report that warping images to align them can suppress lesions visible in only one sequence.

The separation is only possible under one condition, which we state up front. Within a case, at least some readers, or the same reader, must trace on more than one scan. If every reader traced on the same scan, the shift and the shared style are confounded, and the model should collapse to an ordinary multi-reader model. We test that collapse explicitly.

Relation to Prior Work

Three lines of multi-reader modeling supply the reader-style half of our model, and all three assume the readers saw perfectly aligned inputs.

None of these has a term that could absorb a physical shift. Our hypothesis is that their reader decoders silently absorb it, and that this is costly when data are scarce.

Multi-contrast super-resolution work motivates the physical half. Multi-Contrast Super-Resolution MRI Through a Progressive Network and MINet both name residual motion between sequences as their main unsolved failure mode. Both have objective pixel targets and no readers.

Two papers come closest to the intersection, and each leaves the alignment question open.

Our model keeps voxel-level output and models alignment rather than bypassing it.

Finally, Learning Semi-Supervised Medical Image Segmentation from Spatial Registration (CCT-R) shows that registration can serve as a strong prior with a single labeled volume. That work constrains our design in two ways. First, its finding that off-the-shelf registration needs cycle-consistency filtering warns that the displacement field must be regularized and checked rather than trusted. Second, its treatment of seed labels as deterministic is exactly the assumption we drop.

Research Program

We would build the model on a 3D U-Net backbone. It has a reader-latent branch in the Latent Doctor style and a light displacement head. The head takes paired scan features and outputs a low-resolution displacement field, which is upsampled with B-spline interpolation so it stays smooth by construction. The displacement head is trained by two signals. The first is the reader-mask likelihood above. The second is a weak modality-independent similarity term between scans, based on local structural descriptors rather than raw intensity, because intensities differ across contrasts. We would sweep the weight on that term to show the mask likelihood is doing real work.

The analytical part asks when the separation is identifiable. One axis is the ratio of physical shift magnitude to genuine reader spread. The other is the fraction of readers who traced on the non-reference scan. We expect the benefit to vanish when shifts fall below about one voxel or when all readers share one scan. We will report the region where the method helps and the region where it does not.

Data and Benchmarks

There is no public dataset where readers' viewing scans and true inter-scan motion are both known, so we use two tiers.

Semi-synthetic tier. This tier starts from the multi-contrast MRI tasks in QUBIQ (brain tumor, prostate), which carry real masks from 3 to 7 experts. For each case we assign each reader a viewing scan. We apply a known smooth random displacement to the non-reference scan and to the masks of readers assigned to it. This keeps the genuine human disagreement intact while making the physical component exactly known. We train with 1, 5, 10 and all available labeled cases.

Real tier. This tier is a modest new annotation effort on PI-CAI biparametric prostate MRI, used by MFM-Geom. Movement between the T2-weighted and diffusion sequences is real there. Three readers would each outline lesions separately on T2W and on ADC for roughly 40 cases. When the same reader's two outlines disagree, that discrepancy is predominantly physical. When different readers disagree on the same scan, that is predominantly human. This gives a ground-truth-free but sharp test of the separation.

Baselines

The naive reference point is a single U-Net trained on the voxel-wise majority vote of all readers' masks, ignoring both which scan each reader used and any misalignment. More is more: leveraging multi-rater information for whole slide images grading via virtual expert panel reports consensus training at average F1 72.9% and ECE 0.183, against 78.2% and 0.050 for a panel of per-reader models on DEPP. That is a different task, but it indicates how much a consensus model typically loses.

The strongest existing competitor is a multi-reader model trained directly on the misaligned masks: the Latent Doctor Model, plus OMBA-UNet as a second representative. These are the strongest because they already model reader spread at voxel level and could, in principle, absorb physical shifts into reader style. On real QUBIQ, the Multi-decoder U-Net reports Dice of 0.852 and 0.871 on the two brain tumor tasks and 0.553 on prostate task 1, and the challenge summary places winners between 0.80 and 0.85. The OMBA-UNet entry gives no exact Q-Dice or generalized energy distance in our file. No reported result exists for any method on our misaligned semi-synthetic variant, so all comparisons there are run by us.

The registration-first baseline aligns the scans and readers' masks with an off-the-shelf deformable registration before training the same Latent Doctor model. It uses cycle-consistency filtering in the style of CCT-R's best-registration selection, so it is not a strawman.

For fairness, every method uses the same backbone, the same labeled cases, the same augmentation, and an equal hyperparameter search of 20 configurations on a held-out validation split.

Two ablations isolate the key ingredient:

  • Remove the displacement field entirely, which leaves the Latent Doctor model.
  • Make the field reader-specific instead of shared per scan. This tests whether the sharing constraint, not the extra capacity, produces any gain.

We count the proposal as beating the baselines if it does two things on the semi-synthetic tier at 5 and 10 labeled cases. First, it improves QUBIQ threshold-averaged Dice and generalized energy distance over the strongest multi-reader model by more than the seed-to-seed standard deviation. Second, it recovers the injected displacement with endpoint error clearly below that of the registration-first pipeline.

Why not just…?

Why not just register the scans first and then train a multi-reader model? This is the most natural pipeline and is included as a baseline. Prior work gives two reasons to expect it to fall short.

  • Cross-contrast registration aligns strong anatomical edges but can distort or suppress lesions that appear in only one sequence (Yoon et al.; Feng et al.).
  • CCT-R found off-the-shelf registration noisy enough to require filtering.

Registration-first also uses only image intensities. Our model additionally uses the reader masks themselves as evidence about where the shift is. The semi-synthetic tier, where true displacement is known, will show directly whether registration-first recovers it as well. If it does, the proposal reduces to "register first," and we would report that.

Why not just add random misalignment augmentation and let the reader model absorb the shift? This is a real threat when shifts are small relative to reader spread. In that case the reader latent can plausibly soak up the offset at little cost. The counter-argument rests on scarce data. Per-reader capacity that learns a spatial offset is spent on a nuisance, and random-shift augmentation does not teach which direction this patient moved. Song et al. also found that random guidance-target shifts lead networks to learn wrong coordinate mappings rather than invariance. Our sweep over shift magnitude and labeled-case count is designed to locate where augmentation suffices. We will report that boundary rather than claim a uniform win.

Why not just collapse readers into a STAPLE or majority-vote consensus? Consensus removes the very signal we use: which reader traced on which scan. It also produces overconfident boundaries. The Latent Doctor Model reports that distribution modeling achieves KL divergence 0.461 on Gleason2019 and Spearman correlation up to 0.728 with panel entropy, and the virtual-panel calibration gap cited above points the same way. Consensus remains in the study as the naive reference.

Decisive Checks

Three results would settle the question.

First, on the semi-synthetic tier, the fraction of injected displacement recovered by the shared field should track the true displacement magnitude. The reader latent's variance should stay flat as displacement grows. In the no-field ablation, the latent variance should instead rise with displacement, which is the signature of reader decoders absorbing physics.

Second, on the real PI-CAI re-annotation, the model should attribute most of the same-reader, cross-scan discrepancy to the displacement field and most of the between-reader, same-scan discrepancy to the reader latent. We will quantify this as the share of Dice disagreement each component explains. A model that cannot do this on real data has not separated anything, whatever its semi-synthetic scores.

Third, when all readers are restricted to one scan, the gain should vanish. This confirms that improvements come from identifiable structure rather than added capacity.