Sending Clinical Data Only When It Changes the Answer

Hospital monitoring systems move every chest X-ray, ECG and note to central models as soon as it exists, over network equipment that draws most of its peak power even when idle. Machine-learning models that combine these data types are evaluated as if bandwidth and energy were free. The networking literature treats traffic as anonymous bits and knows nothing about which payload matters clinically. We propose to put the two together.

The proposed system decides, for each patient and each heavy data item, whether sending it now would change the downstream clinical prediction. It then schedules the transmissions that can wait into short bursts, so network links and radios can stay in deep sleep between bursts. The thesis has two parts, and both need to be true for the idea to matter. First, much of the heavy multimodal stream carries little marginal predictive value at the moment it is generated. Second, because idle network hardware burns a large fixed power floor, energy savings come from long idle periods rather than from fewer bytes. A policy that only shrinks traffic therefore saves little, while a policy that also reshapes traffic into bursts can save much more.

Core Claim

Two observations from separate fields motivate the claim. In clinical modeling, Autoregressive EHR Foundation Models with Multimodal Inputs combines structured electronic health record (EHR) codes with ECG waveforms, chest X-rays and notes on MIMIC-IV. It finds that zero-shot ICU mortality AUROC rises from 0.8651 (EHR only) to 0.8751 when notes are added. AUROC falls to 0.8624 when chest X-rays are added. So at least one bandwidth-heavy modality is, on average, worse than useless for this task.

In networking, An overview of energy-efficient base station management techniques gives the standard linear power model $P(\rho) = a + b\rho$. Here $\rho \in [0,1]$ is normalized load, $a$ is the fixed power floor and $b$ is the load-dependent part. The same paper reports that $a$ is 60–80% of peak for a base station. Minimization of Network Power Consumption with Redundancy Elimination reports roughly 200 W saved per wide-area link that is actually switched off.

Putting these together, we model the energy of a link serving a ward over a horizon as

$$E = \sum_{\text{active}} (a + b\rho_t)\,\Delta t \;+\; P_{\text{sleep}}\,T_{\text{sleep}} \;+\; c_{\text{wake}}\,N_{\text{wake}},$$

where $T_{\text{sleep}}$ is total time asleep, $P_{\text{sleep}}$ is sleep power, $N_{\text{wake}}$ counts sleep-to-active transitions and $c_{\text{wake}}$ is the energy cost of each one.

If the link never sleeps, cutting bytes only reduces the $b\rho$ term. Savings are then capped near the dynamic share $b/(a+b)$, roughly 20–40% of peak by the figures above. Only policies that create long, uninterrupted idle periods reach the $a$ term. Those policies must also avoid rapid toggling between sleep and active states, which raises $N_{\text{wake}}$ and destabilizes service. Adaptive Dynamic Programming for Energy-Efficient Base Station Cell Switching shows this risk directly: rule-based switching dropped quality of service to 68%, while a predictive controller held 98% with a 20.1% power cut.

The new element is a transmission policy driven by clinical value of information that is jointly shaped for sleep. Prior network work optimizes volume alone. Prior clinical work never models acquisition cost.

Research Program

We build three components on MIMIC-IV, using its ECG, CXR and note sub-databases with their real timestamps.

The first is the downstream predictor. We reimplement the gated cross-attention, latent-compression design of Autoregressive EHR Foundation Models with Multimodal Inputs with strict temporal masking. In this design, small sets of learned query vectors summarize each heavy modality, and a zero-initialized gate controls how much that summary affects the EHR model. Our first target is to reproduce its reported AUROCs.

The second component is a value-of-information estimator. For every heavy item in the training set, we compute a counterfactual: how much the patient's predicted risk changes when the item is included versus masked. We then train a small regressor to predict that change using only information available at the edge before the item is sent. That information is the current structured record, item type and size, time since the last item of that type, and cheap metadata such as the X-ray's order indication. The regressor runs at the device or gateway, so the decision is made before any bytes cross the network.

The third component is a deadline-aware burst scheduler. Each item the estimator deems worth sending gets a clinical deadline that depends on its predicted risk change. Items above an urgency bound go immediately. Alarms and structured vitals always go immediately and are never gated. All other items are queued and released together at the next wake window. The window schedule is chosen by a lightweight dynamic-programming controller in the style of Adaptive Dynamic Programming for Energy-Efficient Base Station Cell Switching, with an explicit penalty on $N_{\text{wake}}$.

Energy is simulated, not measured. The file contains no hospital network power traces, so we instantiate the model above with three published parameter regimes. These are base-station figures from An overview of energy-efficient base station management techniques, wired-link figures from Minimization of Network Power Consumption with Redundancy Elimination, and router leakage shares from BlackOut. We report results separately for each regime rather than claiming one hospital number.

Baselines

The naive reference is always-on full transmission. Every item is sent on arrival over a link that never sleeps, feeding the full four-modality model. Its predictive reference is the 0.8624 AUROC reported for EHR+notes+ECG+CXR in Autoregressive EHR Foundation Models with Multimodal Inputs. Its energy defines 100%.

The strongest simple competitor is static modality pruning: drop ECG and X-rays entirely and send only EHR and notes. This is the best configuration in the cited paper, with a reported zero-shot ICU mortality AUROC of 0.8751. It also removes the heaviest payloads. We run it with the same backbone, data split and tuning budget as our model. Beating it means matching or exceeding 0.8751 within the confidence interval while either using less energy, or showing a clear gain on cases where ECG or X-ray content does matter, such as cardiac-arrhythmia-related outcomes.

The strongest scheduling competitor is an acuity-threshold rule with fixed batching. Heavy items are sent immediately when a structured early-warning risk score exceeds a threshold, and otherwise in fixed windows. One version uses the 15-minute cadence used in production by DEPLOYR. We tune the threshold and window length on validation data with the same search budget given to our policy's trade-off parameter. We compare the two along the full curve of accuracy versus energy, not at a single operating point.

The network-only competitor is a content-blind sleep controller that switches links on aggregate volume. It follows Graph neural network-based cell switching for energy optimization in ultra-dense heterogeneous networks, which reports a 10.41% energy gain while keeping 99.63% of traffic on Milan data, and the adaptive dynamic-programming controller above. This controller sees bytes, not clinical value. Our policy should beat it on delayed urgent items at matched energy.

Two ablations isolate the key ingredient. Value gating without burst scheduling tests whether byte reduction alone saves little, as the energy equation predicts. Burst scheduling without value gating tests how much comes purely from reshaping traffic. A third control drops items at random, at the same rate as our policy, and checks whether the estimator picks better than chance.

Why not just…?

Why not just drop chest X-rays and ECGs permanently, as the multimodal results suggest? This is the most serious threat. On the averaged mortality metric it may be hard to beat. The CXR penalty is an average effect, though, and averages hide subgroups where an image or waveform decides the case. Notes, which also cost transmission, gave the largest gain in the cited work. PheME reports multimodal fusion raising phenotype ROC AUC by 14.28% on average over single modalities, showing that auxiliary data can matter a great deal for some outcomes. We will report per-outcome and per-subgroup results. If permanent pruning matches our policy everywhere, the honest conclusion is that a static rule suffices, and the paper becomes a measurement study of modality value.

Why not just use clinical acuity thresholds and a cron job? This baseline is run with an equal tuning budget. The evidence against it in the file is indirect. Threshold switching in cellular networks caused quality-of-service collapse (Adaptive Dynamic Programming for Energy-Efficient Base Station Cell Switching). Fixed 15-minute polling coincided with AUROC decaying from 0.76 to 0.69 in production (DEPLOYR), although that decay was attributed mainly to data drift and recording delays. Neither result proves the rule fails here, so the accuracy–energy curve comparison is decisive.

Why not just compress at the edge with the learned summary vectors? Compression reduces bytes. By the energy equation, it touches only the $b\rho$ term unless idle periods also lengthen. The bytes-only ablation tests exactly this.

Why not just let standard network sleep controllers handle it? They cannot tell an arrhythmia alarm from a backup job. The urgent-item delay metric will show whether this matters in practice.

Proposed Experiments

The main experiment uses ICU mortality, following the protocol of Autoregressive EHR Foundation Models with Multimodal Inputs. Secondary tasks are length of stay and sepsis onset, defined via Yet Another ICU Benchmark. That benchmark reports mortality AUROC of 0.84–0.87 across sites, which provides a sanity range.

We report five things. The first is AUROC and AUPRC with bootstrap intervals. The second is calibration. The third is time between an item's arrival and its use when the predicted risk shift exceeds 0.05. The fourth is simulated energy as a fraction of always-on under each of the three power regimes, along with sleep fraction and wake count. The fifth is the 99th-percentile delay of urgent and alarm traffic, which must stay at zero added delay by construction; we verify this.

There are three decisive checks. First, the value-of-information estimator must beat random dropping at a matched rate on predictive loss. If it does not, the clinical half of the idea fails. Second, the full policy must clearly beat the bytes-only ablation on energy. If it does not, the networking half fails. Third, at an AUROC no lower than the 0.8751 EHR+notes reference, the full policy must use less simulated energy than the tuned threshold-and-batch rule. If the rule lands within the bootstrap interval of our curve, we will report that a simple scheduler suffices.

A transfer check trains the estimator on MIMIC-IV and applies it to eICU structured streams. YAIB found eICU-trained models generalize better across hospitals, so we expect transfer in that direction to be informative.