A segmentation model trained at one hospital can lose much of its accuracy at a hospital in another region. The domain-shift literature usually treats that loss as a single quantity and fights it with one tool: more augmentation, a sturdier architecture, or adaptation to unlabeled target images. Yet a hospital in another region differs in at least three separate ways. Its scanners and protocols make images look different. Its patients have different anatomy, body habitus, and disease mix. Its radiologists may draw boundaries by different rules. These three causes call for different fixes. Appearance differences can in principle be removed without any target labels. Anatomical differences need training cases that resemble the target population. Annotation differences cannot be fixed from unlabeled images at all.
We propose a measurement protocol that splits a model's cross-site performance drop into these three parts using controlled interventions, and then asks how the part that has nothing to do with appearance grows with population distance from the training region. The claim to test is concrete. After appearance is neutralized, a large, label-dependent share of the remaining cross-region error persists, and it tracks anatomical and annotation distance rather than scanner metadata. If that holds, much of the benchmark progress on domain generalization is progress on only one of three problems.
Core Claim and Why It Is Different
The closest existing work comes from three directions, and none of them makes this split. First, shift-detection systems ask whether a deployment has drifted and what kind of drift it is. Automatic Dataset Shift Identification to Support Safe Deployment of Medical Imaging AI and CheXstray combine model outputs, self-supervised features, and DICOM metadata (the technical header stored with each scan) for this purpose. They flag and label shift. They do not say how many Dice points each cause costs, and they do not intervene to confirm the cause. Second, GeoBS measures how AI errors cluster and decay with physical distance from the training region, using relative-entropy scores over spatial grids, distance lags, and direction sectors. It was built for remote sensing, where error points are dense, and it treats error as one quantity without mechanism. Third, the clinical papers in the population-bias direction supply the motivation. Anatomical reference ranges differ by cohort, as shown for cervical dimensions (Cong et al.) and pediatric urethral length (Li et al.). A localized cohort can also be younger and biologically different from international ones (BRIGHT-2). None of these papers asks what such population differences do to an imaging model once scanner effects are held fixed.
The theoretical anchor that makes the split more than bookkeeping is Causality matters in medical imaging. It argues that in segmentation the image causes the label, so the distribution of unlabeled target images carries no information about how the target site labels. If that is right, the annotation part of our decomposition should not shrink under any label-free adaptation. That is a falsifiable prediction the protocol tests directly.
Research Program
The protocol measures a model at a target site under three switchable interventions and attributes the drop by averaging over their orderings (Shapley attribution over three factors, which needs only eight evaluations per site). Let $D(a,p,\ell)$ be the target Dice score. Here $a$, $p$, and $\ell$ each equal 0 or 1 and say whether appearance, population, or labeling protocol has been matched to the source. The drop to explain is $\Delta = D(1,1,1) - D(0,0,0)$. For example, the appearance share is
$$\phi_a = \tfrac{1}{3}\big[D(1,0,0)-D(0,0,0)\big] + \tfrac{1}{6}\big[D(1,1,0)-D(0,1,0)\big] + \tfrac{1}{6}\big[D(1,0,1)-D(0,0,1)\big] + \tfrac{1}{3}\big[D(1,1,1)-D(0,1,1)\big],$$
and $\phi_p$ and $\phi_\ell$ are defined in the same way, so $\phi_a+\phi_p+\phi_\ell=\Delta$.
The appearance switch maps each target image into the source's intensity and noise characteristics while leaving geometry untouched. It uses a per-site input-space adapter restricted to pointwise and smooth non-linear intensity maps plus noise matching. This borrows the idea from Adapt the Data, Not the Model, which maps shifted inputs back to a frozen predictor's source domain in time series. We adapt it here to imaging. We deliberately do not use diffusion counterfactuals such as FastDiME: their spatial masks suit local shortcuts and handle global contrast shifts poorly, and a generative editor could quietly alter anatomy, which would contaminate the split. Restricting the switch to intensity maps is what makes "anatomy unchanged" checkable. Organ volumes and surface distances computed from ground-truth masks are identical before and after by construction.
The population switch changes what the model was trained on, not the test image. We retrain on a subset of source cases matched to the target site on organ volume, shape descriptors, age, and sex where recorded. The subset has the same size as the unmatched training set, so only composition changes. The labeling switch requires human work. A small subset of target cases, about 30 volumes per site, is re-annotated under the source site's written protocol by annotators trained on source examples. Scoring against these labels instead of the native target labels removes the annotation part.
Once the parts are estimated per site, we regress $\phi_p$ and $\phi_\ell$ on population distance and $\phi_a$ on scanner metadata distance. Population distance is the divergence between source and target distributions of organ-shape descriptors. Scanner distance covers vendor, field strength, and slice thickness. Where site locations are documented, we also compute GeoBS distance-lag scores on each part. With only a few dozen sites these spatial statistics are weak, so we treat them as descriptive, not confirmatory.
Proposed Experiments
The main testbed is AMOS, a multi-center abdominal CT and MRI benchmark. Its authors report that MRI models tested on unseen scanners lost more than 20% mean Dice, while CT transferred relatively well. That contrast is exactly what our split should explain: is the MRI collapse mostly appearance, or does it hide population and labeling parts? We add cross-benchmark transfer between AMOS and the BTCV and Medical Segmentation Decathlon abdominal tasks used in UNETR, treating each benchmark's institutions as distinct sites. The geographic origin of each site will be taken from dataset documentation, and any site without documented origin is excluded from the geographic analysis. For a second modality we use the eight-center polyp segmentation out-of-distribution setting of TransNetR. Colonoscopy appearance varies with camera and lighting, while polyp morphology may vary with population. Segmentation backbones are nnU-Net-style CNNs and UNETR. We report Dice and 95th-percentile Hausdorff distance, with the three attribution shares and bootstrap confidence intervals over target cases.
Baselines
The naive reference point is a model trained on the source sites with standard augmentation and evaluated unchanged on each target. It defines $\Delta$ and tells us whether any method moves it.
The strongest label-free competitor is causality-inspired single-source generalization, GIN plus IPA. It randomizes image contrast with shallow random networks and breaks target–background correlations. We add Domain Game, which separates anatomy from scanner style through a min-max game over geometric transforms, and the architectural approach of TransNetR. I found no reported Dice result on Lacuna for GIN+IPA or Domain Game on AMOS cross-site transfer. The only reported figure for this setting is AMOS's own drop of over 20% mean Dice on MRI from unseen scanners. All baselines are therefore rerun by us on identical site splits, with the same training budget and the same hyperparameter-search budget on a held-out source site, never on target data.
These methods relate to our claim in a specific way. If appearance is the dominant part, they should close most of $\Delta$. Our prediction is that they recover roughly $\phi_a$ and little of $\phi_p+\phi_\ell$. Evidence against us would be a label-free method closing more of the drop than our appearance switch plus population switch combined.
The key ablation replaces our intensity-only appearance switch with a full image-translation model. This tests whether a more powerful harmonizer "explains away" population effects by altering anatomy, which would show that the constrained switch is necessary.
Why not just…?
Why not just train with strong augmentation like GIN and report per-site Dice? That tells you how much of the drop one method closes. It does not tell you what the rest is made of. If GIN+IPA leaves a residual that our split assigns to labeling, no amount of augmentation research will remove it. Those are the numbers our baseline comparison produces for each site.
Why not just pool more multi-center data? Pooling helps whichever part the new data covers, and it is the practical fix for the population part. But it gives no guidance on whether a new region needs new scanners, new patients, or re-annotation. It also cannot fix annotation disagreement, because pooled sites with different protocols average their labels. The population switch in our protocol is itself a controlled version of pooling, so the experiment directly shows how much pooling can buy.
Why not just use existing shift-identification tools? This is the most serious alternative. Automatic Dataset Shift Identification may already correctly say that a site shows covariate or prevalence shift. We will run it on every target site and check whether its predicted shift type agrees with our dominant attribution share. If agreement is high, the cheap detector is enough for triage, and our contribution narrows to magnitudes and to the annotation part, which image-only detectors cannot see in principle.
Why not just compute GeoBS on raw errors? Spatial scores on total error would mix scanner purchasing patterns, which also cluster geographically, with population differences. Our split lets the distance-decay question be asked separately of each part. We acknowledge that the small number of sites limits spatial conclusions.
Decisive Checks
Three results would settle the claim. First, on AMOS MRI, $\phi_a$ should account for most, but not all, of the drop, with a residual confidence interval that excludes zero. Second, no label-free baseline should reduce $\phi_\ell$ reliably. This is the direct test of the causal argument, and a clear reduction would count against it. Third, $\phi_p$ should correlate with anatomical distance more strongly than with scanner distance across sites. If instead the residual vanishes once appearance is matched, then for these benchmarks geographic generalizability reduces to acquisition harmonization, and we would report that negative finding as the main result.
References
- Automatic Dataset Shift Identification to Support Safe Deployment of Medical Imaging AI
- CheXstray: Real-time Multi-Modal Data Concordance for Drift Detection in Medical Imaging AI
- GeoBS: Information-Theoretic Quantification of Geographic Bias in AI Models
- Risk factors of LEEP margin positivity and optimal length of cervical conization in cervical intraepithelial neoplasia
- Age-specific reference values for normal urethral length derived from cross-sectional analysis and implications in hypospadias management
- Bireociclib plus fulvestrant for HR+/HER2- advanced female breast cancer progressed on or after endocrine therapy: phase 3 BRIGHT-2 study interim analysis
- Causality matters in medical imaging
- Adapt the Data, Not the Model: Input-Space Adaptation for Frozen Time-Series Predictors
- Fast Diffusion-Based Counterfactuals for Shortcut Removal and Generation
- AMOS: A Large-Scale Abdominal Multi-Organ Benchmark for Versatile Medical Image Segmentation
- UNETR: Transformers for 3D Medical Image Segmentation
- TransNetR: Transformer-based Residual Network for Polyp Segmentation with Multi-Center Out-of-Distribution Testing
- Causality-Inspired Single-Source Domain Generalization for Medical Image Segmentation
- Domain Game