Reading the Dim Pixel: Sub-Interval Appliance Timing from 30-Minute Smart Meter Data

Most utility smart meters report one average power reading every 30 minutes. Splitting that single household total into per-appliance consumption is called energy disaggregation, or non-intrusive load monitoring. At this sampling rate the field treats a basic effect as noise. When a pool pump or water heater switches on halfway through a half-hour window, the meter records a reading at roughly half the appliance's power. In the image-like reformulation used by PUMPNET, where a year of readings becomes a 48×365 grid of half-hours by days, this reading shows up as a faint "dim pixel" on the edge of a bright rectangle. PUMPNET names these dim pixels as its main source of boundary error. We argue the dim pixel is a measurement, not blur. If you know the appliance's power draw and the background load at that hour, the dim value tells you what fraction of the window the appliance was running. That fraction tells you, to within minutes, when it switched on or off.

The idea in two sentences: in the day-by-time grid, the many fully lit pixels across other days reveal each appliance's power level, and the many dark days reveal the typical background load at each time of day. A network that combines these cross-day estimates with an exact rule that its fine-grained outputs must average back to the observed meter reading can therefore convert boundary readings into minute-level switching times. This would recover detail that Appliance Detection Using Very Low-Frequency Smart Meter Time Series assumes requires a faster meter, though only for appliances whose runs last longer than one sampling window.

Core Claim

For appliances whose operating runs span more than one 30-minute window, sub-interval switching times are identifiable from 30-minute aggregates, at least approximately. Each boundary reading carries one transition. Its value minus the local background, divided by the appliance's power, gives the fraction of the window the appliance was on. Both unknowns, power and background, can be estimated from other cells of the date-time grid.

We propose a two-dimensional encoder–decoder that takes the 48×365 grid and outputs, for each of $A$ appliances plus an "other" channel, a power profile at 1-minute resolution. The final layer projects these outputs so they satisfy the aggregation identity exactly:

$$x_{d,h} = \frac{1}{K}\sum_{k=1}^{K}\Big(\sum_{a=1}^{A} y_{a,d,h,k} + r_{d,h,k}\Big),$$

Here $x_{d,h}$ is the observed reading on day $d$ in half-hour $h$, $K=30$ is the number of minutes per window, $y_{a,d,h,k}$ is the predicted power of appliance $a$ in minute $k$, and $r$ is the unmonitored remainder. Long skip connections, which pass the encoder's full-resolution feature maps directly to the decoder, carry the exact grid position of each dim pixel past the network's compressed middle layers. A heavy downsampling path supplies the cross-day statistics: power level, time-of-day background, and duration regularity.

The distinctive piece is the pairing of the two. The skips deliver "where," the bottleneck delivers "how bright a fully-on cell is," and the projection forces their product to agree with the meter.

Relation to Prior Work

PUMPNET is the closest work and supplies our input representation. It segments pool-pump operation in the date-time grid with a skip-connected U-Net, reporting 94.37% mean intersection-over-union on the Victorian rollout data against roughly 55–56% for 1D baselines. It predicts binary on/off labels at the 30-minute grid resolution for one appliance. It therefore cannot use dim pixels except as ambiguous labels. We change the output space to multi-appliance, sub-interval power and add the conservation projection.

IMG-NILM also turns consumption into heatmaps, but uses a pooling classifier that discards position and handles one appliance at a time. It motivates our decoder rather than constraining it. ADF & TransApp and the 30-minute benchmark of Petralia et al. show that convolutional local-shape extraction matters at low frequency. Both are ownership detectors, however, not profile reconstructors.

Petralia et al. also supply the strongest apparent counter-evidence: moving from 30-minute to 1-minute sampling improves Macro F1 by about 0.1 on average and by up to 0.2 for kettles. We read this as a ceiling to approach, not a contradiction. The timing information we target exists only for runs that cross window boundaries. Kettle-length events sit entirely inside one window, so their timing is genuinely lost, and we will report only their energy.

On the constraint side, Signal Aggregate Constraints in Additive Factorial HMMs shows that forcing predicted totals to match energy priors reduces normalized disaggregation error by 45%. Energy Disaggregation via Discriminative Sparse Coding shows that reconstruction-trained components "steal" energy from each other unless trained on disaggregation error directly. These papers supply the method for our output layer. We enforce conservation per cell, which is an exact identity rather than a prior, and we train on per-appliance error so the projection cannot be satisfied by dumping energy into one channel.

From the detail-preservation literature, Root Gap Correction with a Deep Inpainting Model and SEGAN supply the recipe of long skips plus an absolute-error (L1) loss to avoid averaged, blurry outputs. FC-DenseNet supplies a parameter-efficient dense backbone, 9.4M parameters versus over 134M for FCN-8s. We use it to stay far below STAFN's 57.5M parameters.

Research Program

Training targets come from sub-metered datasets. We take UK-DALE (dataset), with appliance channels at 6-second resolution, and REFIT. We average the whole-house signal to 30 minutes to form the input grid and resample the appliance channels to 1 minute as targets, so the synthetic input matches what a utility meter would record. Appliances are grouped by run length relative to the window: pumps, water heaters, and fridges/freezers as long runs; washing machines and dishwashers as multi-stage; kettles and microwaves as short events.

The model is a FC-DenseNet-style 2D encoder–decoder on the 48×365 grid. A depth-to-time output head expands each cell into 30 minutes per channel, followed by the closed-form projection. The projection distributes each cell's residual across channels in proportion to the predicted magnitudes, keeping all outputs non-negative.

The loss is per-appliance L1 at 1-minute resolution, plus a transition-time term on detected edges. We will analyze identifiability directly. For a synthetic single appliance with known power and flat background, onset error should be bounded by background noise divided by appliance power, times 30 minutes. This follows from inverting the dim value, and we check whether the learned model tracks that bound as background noise increases.

Baselines

The naive reference is the "hold" upsampler: assign each 30-minute appliance estimate uniformly across its 30 minutes, which places transitions at window edges. Its timing error should be about 7.5 minutes on average for uniformly random onsets. Any method must beat it to claim sub-interval recovery.

A stronger heuristic is analytic inversion. Estimate appliance power as the median of fully-on cells and background as the median of same-hour cells on off days. Then invert each dim pixel into a fraction placed adjacent to the neighbouring on-cell. This baseline tests whether a network is needed at all.

The strongest existing method is PUMPNET's residual-dense U-Net, extended to multi-channel output and to regression of 30-minute appliance power, then hold-upsampled. Its reported result is 94.37% mean IoU at interval level on the Victorian data (PUMPNET). For sub-interval timing there is no reported result found on Lacuna, so we will retrain it on identical UK-DALE/REFIT splits.

A 1D alternative is a SEGAN-style 1D skip-connected encoder–decoder operating on the raw 17,520-step series with the same 1-minute head and projection. Its dilations will be widened to span weeks so that cross-day context is reachable. We also include the Neural NILM denoising autoencoder (Neural NILM), which reports average F1 of 0.53 on unseen houses at its native resolution.

As an upper reference, the same architecture is trained on 1-minute aggregate input. All learned models get the same splits with held-out houses, the same parameter budget within 20%, and the same number of hyperparameter trials.

Three ablations isolate the key ingredients: removing the conservation projection, swapping L1 for squared error, and shuffling grid columns. Shuffling columns destroys day ordering but keeps time-of-day, which tests whether cross-day context is what supplies power and background estimates. Beating the extended PUMPNET means lower median onset and offset error at equal or better per-appliance energy error on long-run appliances, measured on held-out houses.

Why not just…?

Why not just extend PUMPNET to several output channels? That is our strongest baseline. Its 30-minute output resolution caps timing accuracy at the hold-upsampler's level by construction. If it matches us on energy but not timing, the gain is attributable to the sub-interval head and projection. If the extended PUMPNET plus analytic inversion as post-processing matches us, the network contribution is only the multi-appliance segmentation, and we will report it that way.

Why not just use the analytic inversion? For a single dominant appliance it may work well, and that would itself be a useful finding. It breaks when several appliances share a boundary cell or when background varies. We expect the gap to grow with the number of concurrently active appliances. We will stratify results by concurrency so this is measured rather than assumed.

Why not just use a 1D model with long context? This is a real threat. A dilated 1D network can in principle reach the same-hour readings on other days. The 2D grid puts them one convolution step apart, but nothing proves this matters. The parameter-matched 1D baseline with identical head and projection settles the question. If it ties, our claim reduces to "dim pixels are invertible under conservation," independent of the 2D arrangement.

Why not just install faster meters? The installed base samples at 15–60 minutes, which is the regime these papers target. The 1-minute-input reference tells us how much of the faster-meter benefit reported by Petralia et al. we recover for long-run appliances.

Proposed Experiments

The primary benchmark is house-held-out UK-DALE and REFIT with synthetic 30-minute aggregation. Metrics are median onset and offset error in minutes, per-appliance energy mean absolute error, normalized disaggregation error, and 1-minute state F1, all reported by run-length group. A secondary check uses the Victorian rollout data at interval level against PUMPNET's 94.37% mean IoU. If its operation records carry sub-interval timestamps and the data are accessible, we will also evaluate timing there.

Three results would be decisive. First, on long-run appliances the model should cut median timing error well below the hold upsampler's roughly 7.5 minutes. Second, the column-shuffle ablation should erase most of that gain. Third, for kettle-length events timing error should stay near the naive level; if it did not, that would signal leakage rather than recovery. If the projection-free ablation matches the full model, the conservation constraint is redundant with L1 training, and we will drop it from the claim.