Bone is thought to respond to exercise like a switch rather than a dial. Below some strain level, loading is ignored. Above it, bone-forming cells are recruited. The clinical evidence for this is real but thin. A meta-analysis of 17 trials in postmenopausal women found that hip density improved only when resistance training reached at least 70% of the heaviest weight a person can lift once (written "1RM", one-repetition maximum) (Optimal resistance training parameters...). Those trials last a year at most, compare one or two fixed doses, and differ so much from each other that the pooled spine and femoral-neck estimates carry heterogeneity above 85%. They cannot tell a true threshold apart from a smooth dose–response curve. A small simulation study points the other way, toward a roughly linear relation between modeled spinal load and density change (Musculoskeletal model predicted paraspinal loading...).
We propose to settle the shape of this curve with data hospitals already hold. Patients on hormone-suppressing cancer therapy lose bone quickly. They are often referred to supervised exercise programs whose session logs record the load lifted. They also receive abdominal and pelvic CT scans every few months for cancer surveillance. Automated software can turn each of those scans into a volumetric bone density measurement of the lumbar spine and both hips. Linking the exercise logs to the scan series turns an ordinary retrospective cohort into a dose-resolved, multi-year study of how loading intensity changes the rate of bone loss. The design is analyzed as an emulated trial, and its main defense against the "healthy exerciser" bias is to compare people who all attended a supervised program but trained at different intensities.
Core Claim
The claim is narrow and testable. Among adults on androgen-deprivation therapy for prostate cancer or aromatase inhibitors for breast cancer, the slope of trabecular density loss on surveillance CT depends on logged training intensity through a hinge, not a line. Below a threshold near 70% 1RM, more intensity barely changes the slope. Above it, the slope flattens sharply.
We also predict that the threshold behaves differently at different sites:
- Femoral neck: sharp threshold.
- Lumbar spine: softer response, driven more by session duration.
- Trochanter: little response at any intensity.
This pattern mirrors the site-specific subgroup results of the meta-analysis. If the data favor a linear curve, or if the threshold cannot be located more precisely than the full range of observed intensities, the claim fails. That negative result would itself change how exercise is prescribed.
What Exists and What Is Missing
Two groups of prior work motivate the design but do not address it.
Opportunistic CT studies. These show that routine scans carry clinically meaningful density information. A 420-patient retrospective cohort used an automated segmentation pipeline (anduin.bonescreen.de) to extract lumbar volumetric density. Each standard-deviation decrease predicted 3.5-fold higher odds of incident vertebral fracture (Incidental vertebral fracture prediction...). A 58-patient fracture-clinic cohort found that opportunistic density separated future fracturers when DXA T-scores did not (Opportunistic QCT...). A cadaver study bounded the measurement error across scanner settings at a root-mean-square error of roughly 9 to 13 mg/cm³ (Automated extraction of vertebral BMD...). All three use a single baseline scan and record no exposure at all. We reuse their extraction machinery, but treat the scans as a repeated-measures outcome.
Large osteoporosis cohorts. The OHDSI comparison of alendronate and raloxifene ran an active-comparator new-user design over more than 300 million records, with calibration against 147 negative-control outcomes (Comparative safety and effectiveness of alendronate versus raloxifene). It names the absence of both bone density and physical activity data as a central limitation. We borrow its design logic and fill exactly those two gaps, at the price of far smaller scale.
Causal methods for dose thresholds. Two papers supply the methods for estimating a continuous dose–response from observational data. One emulated a trial comparing oxygenation thresholds for starting ventilation, using Bayesian G-computation with Bayesian additive regression trees (Oxygenation thresholds...). G-computation simulates each patient's outcome under each candidate strategy; Bayesian additive regression trees, or BART, are a flexible tree-ensemble regression model. The other recasts causal effects as prediction of outcomes in a hypothetical trial population (Causal predictive inference and target trial emulation). Neither has been applied to a mechanical dose.
Constraints. The cataloged weaknesses of retrospective studies are our main design constraints (Systemic Biases and Causal Limitations in Retrospective Studies). Propensity matching is blind to unrecorded frailty. Sicker patients are imaged more often. Missingness is not random.
Research Program
Cohort. We build the cohort in health systems that run supervised exercise-oncology services. Data are harmonized to the OMOP common data model so the analysis can be federated across sites. Eligible patients:
- start androgen-deprivation therapy or an aromatase inhibitor;
- have at least one contrast-corrected abdominal or pelvic CT within 90 days before that start;
- have at least two follow-up scans over the next 12 to 36 months.
Time zero. Time zero is the first program session, or a matched calendar point for non-attenders. Grace periods are defined so that exposure cannot be determined after time zero, which avoids immortal-time bias.
Exposure. Exposure comes from the session logs. These are often free text, so a language-model extractor converts each session into exercise type, load as a percentage of tested 1RM, sets, and duration. A double-abstracted random sample of at least several hundred sessions checks the extraction. The primary dose is the median top-set intensity over the first 24 weeks. Secondary doses are cumulative sessions at or above each intensity cut-point.
Mechanical load sub-study. For the spine, we convert logged exercises into internal loads with the OpenSim full-body lumbar spine model: muscle force plus intervertebral compression, using standard per-exercise profiles from Musculoskeletal model predicted paraspinal loading.... This tests whether a modeled mechanical dose explains density change better than %1RM does.
Outcome. The outcome is the annualized change in trabecular density at four sites: the L1–L4 vertebrae, femoral neck, total hip, and trochanter. Density is extracted by the anduin pipeline with its contrast correction. Scanner model enters as a fixed effect, and protocol changes are flagged. Paraspinal and gluteal muscle cross-sectional area are extracted from the same scans as a secondary measure of mechanism. Incident fragility fractures from diagnosis and procedure codes are a secondary outcome. We expect the cohort to be underpowered for fractures and will say so.
Dose–response model. The primary model is a per-site hinge regression, with symbols defined as follows:
- $\Delta_{is}$: annualized density change for patient $i$ at site $s$;
- $x_i$: logged intensity in %1RM;
- $\tau_s$: the site-specific threshold;
- $(\cdot)_+$: takes the positive part;
- $f(z_i)$: a BART adjustment for baseline covariates $z_i$ (age, therapy type, baseline density, body mass index, comorbidity, prior fracture, bone-active drugs, cancer stage);
- $\varepsilon_{is}$: the residual.
$$\Delta_{is} = f(z_i) + \beta_s x_i + \gamma_s (x_i - \tau_s)_+ + \varepsilon_{is}$$
The threshold hypothesis predicts $\gamma_s > 0$ with $\beta_s \approx 0$ at the femoral neck. It also predicts a smaller $\gamma_s$ at the spine and no response at the trochanter.
Estimation. We fit this both within G-computation and with inverse-probability weighting on a generalized propensity score for continuous dose. Results are reported as the counterfactual mean density slope under strategies of 50%, 60%, 70%, and 80% 1RM. The linear and hinge models are compared by held-out predictive log-likelihood across sites.
Baselines
Naive reference point. The first baseline is the unadjusted difference in density slope between program attenders and non-attenders. It shows how large the raw association looks before any bias control. We expect it to be inflated by healthy-user selection. It is not a competitor to beat; it calibrates how much the design removes.
Strongest existing method. The second baseline is the analysis the field would run today, transplanted from the OHDSI alendronate study (Comparative safety and effectiveness...). It is a new-user cohort with large-scale propensity stratification on all recorded covariates and empirical calibration against negative-control outcomes. Here, the binary exposure is "attended a supervised program." This is the most credible established way to estimate a real-world intervention effect on bone outcomes. Its reported numbers are effects of drugs on fractures, such as a hip-fracture hazard ratio of 1.03 (95% CI 0.94–1.13). No reported result was found on Lacuna for any exercise-intensity exposure on opportunistic CT density trajectories, so there is no published number to beat.
Fairness rules for this comparison:
- Both analyses use identical patients, time zero, covariates, outcome extraction, and follow-up.
- Both use the same pre-registered negative-control set.
Our design beats this baseline if it does three things the binary design cannot:
- recovers a site-specific dose–response;
- passes the pre-exposure placebo test (described below) where the binary contrast fails it;
- yields calibrated confidence intervals that remain informative after negative-control calibration.
Ablations. Two ablations isolate the key ingredient, which is intensity resolution among attenders.
- The first keeps the cohort restricted to attenders and the full causal machinery, but collapses dose to session count, ignoring load. If session count explains density change as well as intensity does, the threshold story is wrong.
- The second fits the same model with a linear dose term only. It is the direct competitor to the hinge.
Outcome-measure benchmark. We also report the prognostic value of the outcome measure itself. We check whether our extracted density reproduces the fracture association reported for the extraction pipeline (OR 3.5 per standard-deviation decrease, AIC 165.2 versus 181.0 for fracture history alone, Incidental vertebral fracture prediction...). This confirms the surrogate behaves in our population as it did in theirs.
Why not just…?
Why not just run another randomized trial? Trials are the right tool for the average effect of one prescribed regimen, and 17 already exist (Optimal resistance training parameters...). They are the wrong tool for locating a threshold. Each trial fixes one or two intensities. Follow-up rarely exceeds 48 weeks. Pooling across trials confounds intensity with population and protocol, which is why heterogeneity exceeds 85%. Randomizing frail patients with bone metastasis risk to heavy lifting also raises real ethical barriers. Our design is not a substitute for a confirmatory trial. If it locates a threshold, it tells such a trial which two arms to compare.
Why not just use self-reported physical activity in a large biobank? Questionnaires mostly capture walking volume. The threshold hypothesis is about peak intensity, which self-report measures poorly. Self-reported activity is also maximally exposed to healthy-user confounding. This alternative is a real threat on scale, because biobanks are orders of magnitude larger. We address it with the session-count ablation, which mimics a volume-only exposure inside our own data. If volume predicts density slope as well as logged intensity, the case for intensity-resolved logs collapses and biobank studies would be the better route.
Why not just count fractures, as the OHDSI study did? In cohorts of the size a few exercise-oncology services can supply, fractures over two to three years will be too few for a dose–response curve. Density measured on CT is a validated surrogate with a strong association with incident fracture in a comparable hospital population. We keep fracture as a secondary endpoint and state its power honestly. We do not claim fracture effects from density alone.
Why not just use muscle size on CT as the loading measure? This avoids the logs entirely and would scale to every scanned patient. However, muscle area reflects nutrition, cachexia, and cancer burden as much as training, so it is badly confounded as an exposure. We therefore treat it as a mediator. If the intensity effect on bone runs mostly through muscle gain, that is informative about mechanism. If muscle area alone predicts density slope as well as logged intensity does, the simpler design wins and we would say so.
Proposed Experiments and Decisive Checks
Feasibility phase. We first count, at each partner site, the eligible patients with linkable logs and at least three scans. The sample-size calculation for the hinge contrast at the femoral neck uses the extraction error bounds from the cadaver study. The threshold analysis proceeds only if the calculation shows adequate precision.
Primary analysis. We estimate the counterfactual density slopes at four intensity levels for each of the four sites. The hinge and linear models are compared by held-out likelihood.
Pre-exposure placebo test. Many patients have surveillance scans before program entry. If future high-intensity trainers already lost bone more slowly before they started, confounding is present and the dose estimates are not credible. The test is to regress the pre-period density slope on later intensity, using the same model.
Negative-control outcomes. We re-run the full pipeline on outcomes with no plausible mechanical link to bone loading, such as incident cataract diagnosis or hospitalization for infection. Their estimated "effects" calibrate the confidence intervals, following the OHDSI practice.
Within-person site contrast. The trochanter, which did not respond in the meta-analysis, serves as an internal control. A whole-body confounder should shift all sites equally. A mechanical effect should spare the trochanter and concentrate at the femoral neck.
Mechanical dose versus %1RM. On the spine, we compare OpenSim-modeled internal load with %1RM as the dose variable. This tests whether the correlation of 0.687 reported in ten women (Musculoskeletal model predicted paraspinal loading...) generalizes to a clinical cohort and outperforms the simpler measure.
Decision rule. The threshold claim survives only under all of the following conditions:
- the placebo test is null;
- negative-control-calibrated intervals for $\gamma$ at the femoral neck exclude zero;
- the hinge beats the linear model on held-out data;
- the trochanter effect is near null.
References
- Optimal resistance training parameters for improving bone mineral density in postmenopausal women: a systematic review and meta-analysis
- Musculoskeletal model predicted paraspinal loading may quick estimate the effect of exercise on spine BMD
- Incidental vertebral fracture prediction using neuronal network-based automatic spine segmentation and volumetric bone mineral density extraction from routine clinical CT scans
- Opportunistic QCT Bone Mineral Density Measurements Predicting Osteoporotic Fractures: A Use Case in a Prospective Clinical Cohort
- Automated extraction of vertebral bone mineral density from imaging with various scan parameters: a cadaver study with correlation to quantitative computed tomography
- Comparative safety and effectiveness of alendronate versus raloxifene in women with osteoporosis
- Oxygenation thresholds for invasive ventilation in hypoxemic respiratory failure: a target trial emulation in two cohorts
- Causal predictive inference and target trial emulation
- Experiences about no-reflow in percutaneous transluminal coronary intervention of acute coronary syndrome