Rare-event searches, such as the hunt for neutrinoless double-beta decay or for dark-matter scatters, now use neural networks to tell signal-like detector pulses from background pulses. A pulse here is the voltage trace a detector records over time when a particle deposits energy. The networks read pulses as fixed-length vectors, and their scores are then fed into the likelihood fits that set discovery significance. This note argues that a hidden mathematical fact governs how trustworthy those scores are. A pulse is really a continuous function. In the space of continuous functions, two noisy random processes can be told apart in two very different ways. They can differ in their average shape, measured relative to the noise. Or they can differ in the fine statistical texture of the noise itself. The first kind of difference yields a finite, stable likelihood ratio. The second kind yields "perfect" separation that appears only at fine resolution, and it typically reflects how the noise was modeled rather than the physics.
We propose to build a pulse-discrimination statistic that uses only the first, stable kind of difference. We then measure, for any classifier, how much of its power comes from the second, fragile kind. The diagnostic is simple: refine the sampling rate and watch whether discrimination converges to a limit or drifts toward perfect separation. A drift toward perfect separation signals reliance on noise texture. That reliance is exactly what turns into an unmodeled systematic error when only a handful of events decide a $5\sigma$ claim.
Core Claim
In infinite dimensions, the Feldman–Hájek theorem says two Gaussian measures are either equivalent or mutually singular. Equivalent means each assigns positive probability to the same sets. Mutually singular means they live on disjoint sets, so a perfect test exists in principle. The research file treats this singularity as an obstacle to inference (Pillai & Thiéry; Burt et al.). For detector physics, we read it as a warning label instead. If a learned classifier's apparent power grows without bound as the digitizer samples faster, it is exploiting a singular direction. Singular directions in real detectors are differences in noise covariance between simulation and data, or between calibration-source and physics runs. Such power will not transfer.
Our statistic models each event class as a mixture, over latent physical configurations $z$ (interaction position, energy, number of sites), of a deterministic mean pulse $m_\theta(z)$ plus shared detector noise drawn from a Gaussian measure with covariance $C$. The covariance is estimated from baseline traces. By the Cameron–Martin theorem, each mixture component is equivalent to the pure-noise measure whenever $m_\theta(z)$ lies in the Cameron–Martin space $C^{1/2}L^2$, the space of "smooth enough relative to the noise" functions. Its log-density with respect to noise is then finite:
$$\log \frac{dP_{z}}{dP_0}(u) = \langle m_\theta(z), u\rangle_{C} - \tfrac12 \| m_\theta(z)\|_{C}^2 ,$$
Here $u$ is the observed waveform and $\langle a,b\rangle_C = \langle C^{-1/2}a, C^{-1/2}b\rangle$ is the noise-whitened inner product. The per-event signal-to-background ratio is the ratio of the two mixtures of these exponentials. It is a ratio of finite quantities, it is well defined at every resolution, and it enters directly as the event-level density in an unbinned extended likelihood.
This also resolves the tension raised against Dashti et al.. Their consistency results require the true function to lie in the Cameron–Martin space, which rough detector waveforms never do. In our construction only the mean pulse must lie there. The observation can be as rough as white electronic noise.
Two things are new. The first is a learned, resolution-independent, position-conditioned mean-pulse model inside an exact Cameron–Martin likelihood ratio, used as the observable of a Poisson extended likelihood. The second is a resolution-refinement diagnostic that splits any discriminator's power into an equivalent (robust) part and a singular (fragile) part.
Research Program
The mean-pulse model $m_\theta(z)$ is a Fourier Neural Operator, a network that maps between functions and can be evaluated on any time grid (Li et al.). This lets the same likelihood ratio be computed at 50 MHz or 500 MHz sampling without retraining. We train it on calibration pulses by fitting each pulse's latent $z$ with the Onsager–Machlup objective, data misfit plus Cameron–Martin penalty, from Dashti et al.. Dashti et al. supply that method; we apply it to a detector forward model rather than a PDE. We use the MRA-FNO code (MRA-FNO) as a starting point.
The latent integral over $z$ is approximated by importance sampling around the per-event fit. The signal prior over $z$ is restricted to single-site configurations; the background prior admits multi-site ones.
The noise covariance is estimated from pre-trigger baselines and regularized as $C+\gamma I$. This is the same unitization used to make divergences finite in Minh Ha Quang & Nielsen and in the Fisher–Rao geometry of equivalent Gaussian measures. The file lists automatic selection of $\gamma$ as open. We choose $\gamma$ as the smallest value for which the per-event log-ratio changes by less than a fixed tolerance between successive halvings of the sampling interval. That gives a data-driven criterion tied to the quantity we care about.
For the diagnostic, we also estimate how far apart the class-conditional noise covariances are. We use the regularized Hilbert–Schmidt log-distance from the Fisher–Rao paper, which is finite exactly when the measures are equivalent. This tells us how much separation is in principle available from covariance texture alone. For a learned classifier, we compute its separation (area under the ROC curve and the implied discovery significance) at sampling rates from 1× to 8× the native rate. We fit the trend to see whether it saturates or keeps climbing.
Baselines
The naive reference is the hand-crafted ratio of peak current to total energy, $A/E$, applied with a cut and a one-dimensional unbinned fit. It is the operating standard in germanium searches. Holl et al. report that their deep model only matched it, at 90% background rejection and 90% signal acceptance on the $^{228}$Th double-escape-peak versus full-energy-peak benchmark. We will reproduce $A/E$ on the same events and use its rejection at 90% acceptance as the floor.
The strongest existing method is the learned fixed-grid discriminator. Concretely, this is the convolutional autoencoder of Holl et al., which compresses 256 samples into 7 features and feeds a 141-parameter classifier, reported at 90% rejection and 90% acceptance. We also include a larger CNN trained end to end on the same split. At the experiment scale, the closest analogue is the EXO-200 topology network, credited with a roughly 25% sensitivity gain and signal efficiency raised from 80.8% to 96.4±3.0% (EXO-200). Those EXO-200 numbers are not on our benchmark and serve only as context. The CNN gets the same training pulses, an equal hyperparameter search budget, and linear interpolation to its native grid whenever the test resolution differs. Its calibrated score enters the same unbinned extended likelihood as our ratio.
Beating it means two things. On nominal data we must match it within statistical error. Under covariance shift and resolution change, we must retain at least half of the CNN's degradation in discovery significance as an advantage, and the fitted signal yield must be unbiased when the CNN's yield is not.
The key-ingredient ablation is a classical matched filter: the same Cameron–Martin ratio with a single fixed mean template per class instead of the position-conditioned operator. A second ablation is a "full" Gaussian ratio that also uses class-specific covariances, which deliberately admits the singular part. The first isolates the value of the learned mean model. The second isolates the cost of using covariance texture.
Why not just…?
Why not just resample waveforms to 256 samples and keep the CNN? For the narrow goal of digitizer independence, this would probably work about as well. That is why discretization invariance is not our main claim. The real question is whether the CNN's power rests on noise texture. Interpolation cannot answer that, and the refinement diagnostic can. If the CNN's separation saturates with resolution and survives covariance shift as well as ours does, our central claim is false. The experiment below is designed to show that plainly.
Why not just train the CNN with noise augmentation drawn from many covariance models? This is the most serious threat. Randomizing the noise during training pushes a flexible classifier away from singular directions, which may achieve much of what our construction enforces by design. We include it as a baseline with the same augmentation family the evaluation shifts are drawn from. That favors the baseline, since in reality the true data-versus-simulation shift is unknown. We will also test it on a held-out shift family it never saw. If augmentation closes the gap on held-out shifts, the remaining contributions are interpretability, an exact per-event density for the unbinned fit, and the diagnostic. We would report that outcome honestly.
Why not just estimate the density ratio on summary features, or fit a functional generative model? Regularized ratio estimation in a reproducing-kernel space (Nguyen et al.) works on low-dimensional Euclidean inputs, and its evidence is one-dimensional Gaussian examples. Applied to summaries, it inherits the information loss of $A/E$. Functional Flow Matching (Kerrigan et al.) models full waveform distributions but deliberately avoids evaluating likelihoods, which is exactly the quantity an extended likelihood needs. The velocity-based functional KL of Wang et al. gives class-level divergences, not per-event ratios. We use its code (functional-kl) only to cross-check the total information in the equivalent part on synthetic data with an analytic answer.
Proposed Experiments
The first testbed is the HPGe $^{228}$Th pulse benchmark of Holl et al., if the waveforms are obtainable. As a guaranteed fallback, we generate germanium-like pulses with known single- and multi-site structure and known colored noise, where the equivalent/singular split is analytically computable.
The second testbed is synthetic liquid-argon pulses drawn from the DEAP-3600 pulse-shape model (Adhikari et al.). That model includes the fast singlet, the roughly 1445 ns triplet, the 30–100 ns intermediate component, and the roughly 10% millisecond-scale wavelength-shifter emission. We train with that emission tail correctly modeled and test with it mismodeled. This mirrors the systematic the file flags as indistinguishable from signal at low counts. No reported result was found on Lacuna for learned pulse discrimination on DEAP-3600 waveforms, so here the baselines are run by us.
The decisive check is the refinement curve under shift. On simulated noise, we expect the CNN and the full-covariance ratio to keep gaining separation as sampling refines, while our ratio saturates. On shifted noise, we expect that extra gain to vanish or invert, while our ratio holds steady.
Downstream, we inject a small Poisson signal (tens of events against a fixed background expectation) and run toy experiments of the extended unbinned fit. We report three quantities: median discovery significance, exposure needed for $5\sigma$, and bias plus coverage of the fitted signal count under each shift.
The proposal succeeds if, at matched nominal performance, our statistic shows smaller significance loss and correct coverage under shift where the CNN shows bias. It fails if noise-augmented CNNs match it on held-out shifts.
References
- Noisy gradient flow from a random walk in Hilbert space
- Understanding Variational Inference in Function-Space
- MAP estimators and their consistency in Bayesian nonparametric inverse problems
- Neural Operator: Learning Maps Between Function Spaces With Applications to PDEs
- Geometric Jensen-Shannon Divergence Between Gaussian Measures on Hilbert Space
- Fisher–Rao geometry of equivalent Gaussian measures on infinite-dimensional Hilbert spaces
- Deep learning based pulse shape discrimination for germanium detectors
- Search for Neutrinoless Double-<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mrow><mml:mi>β</mml:mi></mml:mrow></mml:math>Decay with the Complete EXO-200 Dataset
- On regularized Radon-Nikodym differentiation
- Functional Flow Matching
- Relative Entropy Estimation in Function Space: Theory and Applications to Trajectory Inference
- The liquid-argon scintillation pulseshape in DEAP-3600