Kinematic-Fit Statistics for Detecting Weak Sub-Gap Absorption

Particle physicists face a familiar problem. Their detectors blur every measured momentum, so the peaks they look for are smeared and buried under random coincidences. Their standard remedy is a kinematic constraint fit. Each event's measurements are nudged, within their known uncertainties, until they exactly satisfy laws that must hold, such as energy and momentum conservation or a known intermediate mass. The size of the nudge that was needed, a $\chi^2$ score, then says whether the event is consistent with the hypothesis at all. Materials chemists face a structurally similar problem when they claim that doping or defect engineering has made a wide-gap oxide absorb visible light. The evidence is usually a weak absorption shoulder below the band edge. That shoulder is read from noisy reflectance, transmittance and ellipsometry spectra through a model someone chose. Whether it is real, how large it is, and whether it comes from one defect type or two is rarely stated with a significance attached.

This note proposes to transfer the machinery of kinematic fitting to optical spectroscopy of bandgap-engineered films, without the particle-physics parameterization. Measured spectra would be adjusted within their covariances until they satisfy model-free physical constraints: energy conservation between reflected, transmitted and absorbed light; causality (Kramers–Kronig) linking the real and imaginary dielectric response; and a pinned host band edge taken from an undoped reference sample, the analogue of a known-mass constraint. Competing defect hypotheses are then compared by calibrated likelihood ratios. The result is a quantified detection limit for sub-gap absorption as a function of collected photons. The claim is that this lowers the smallest detectable mid-gap absorption at fixed exposure. It also turns hypotheses such as "Ti³⁺ versus oxygen vacancy" into testable statements. Both come from adding hard constraints and calibrated goodness-of-fit, not a better oscillator formula.

Core Claim

Three bodies of work frame the idea. In particle physics, constraint fits of increasing order sharpen resonances and reject wrong hypotheses. Four-momentum conservation removes events with missing particles in Measurement of the final states ωπ0, ρη… and sharpens parent masses in New measurement of exclusive decays of the χc0 and χc2…. Adding known intermediate masses gives the five- and six-constraint fits of De Mori et al. and Ablikim et al. on ψ(3686)→Σ̄⁰Λ. These papers supply the method.

On the materials side, a set of papers motivates the gap. Ti3+ Self-Doping of TiO2 Boosts Its Photocatalytic Performance reports a gap narrowed from 3.12–3.31 eV to 2.20 eV and attributes it to a combination of Ti³⁺ and oxygen vacancies. The file notes that separating the two contributions remains unresolved. Ballester et al. fit Cu₃N films jointly across multi-angle ellipsometry and transmittance/reflectance with Tauc–Lorentz, Gaussian and Drude oscillators. They resolve indirect (1.83–1.85 eV) and direct (2.38–2.39 eV) transitions and report Urbach energies up to about 336 meV. That paper is the closest existing work and the method to beat.

The third direction, statistical sensitivity, sets the constraint. Abbasi et al. and Schoorlemmer et al. show measurements where counting noise, not systematics, limits the conclusion. In that regime the only ways forward are more exposure or more information extracted per count.

What would be new relative to Ballester et al. is this. Their fit commits to an oscillator family and then fits its parameters. When the scientific question is whether a weak sub-gap band exists, the oscillator family largely decides the answer. The proposal instead represents the imaginary dielectric function on a fine nonparametric energy grid and imposes only constraints that must hold. It reports a detection significance calibrated by simulated pseudo-experiments, as particle physicists do. It also uses pull distributions to test whether the instrument covariances are correct. The file lists that last point as an open weakness of kinematic fitting itself.

Research Program

Let $y$ be the stacked measured spectra: reflectance, transmittance and the two ellipsometric angles at every wavelength and angle. Let $V$ be their covariance. Let $\hat y$ be the adjusted spectra. Let $\theta$ collect the film thickness, roughness, a nonnegative grid of $\varepsilon_2(E)$ values and a small number of hypothesis parameters, such as the amplitude $A$ of a localized sub-gap band. The fit solves

$$\chi^2_{\min}(H) = \min_{\hat y,\theta}\ (y-\hat y)^\top V^{-1}(y-\hat y) \quad \text{subject to} \quad C_k(\hat y,\theta)=0,$$

where the constraints $C_k$ encode four things. The first is the optical forward model, including $R+T+A=1$. The second is discrete Kramers–Kronig consistency of $\varepsilon_1$ with $\varepsilon_2$, with a constant and pole terms standing in for out-of-range absorption. The third is thickness shared across instruments. The fourth, under hypothesis $H$, is the host edge fixed to the value measured on the undoped reference. This fixed edge is the analogue of pinning $M_{\pi^0}$.

The fit is solved with Lagrange multipliers, exactly as in particle-physics fitters. Positivity of $\varepsilon_2$ is enforced as an inequality. The test statistic for a sub-gap state is $q = \chi^2_{\min}(H_0) - \chi^2_{\min}(H_1)$. Here $H_0$ allows only an Urbach exponential tail below the pinned edge, and $H_1$ adds one or two localized bands. The distribution of $q$ under $H_0$ is obtained from simulated pseudo-experiments, not asymptotic formulas, because positivity constraints break the usual $\chi^2$ assumptions.

Sensitivity is the central deliverable. For shot-noise-limited spectra, the Fisher information on $A$ grows linearly in the collected photon count $N$. The minimum amplitude detectable at fixed significance therefore scales as $A_{\min}\propto 1/\sqrt{N}$. The constant in front of that scaling is set by how strongly $A$ correlates with the nuisance parameters, above all thickness and the tail slope. The constraints act by breaking those correlations. The program will measure the ratio of $A_{\min}$ with and without each constraint and express it as an equivalent exposure factor $N_{\text{unconstrained}}/N_{\text{constrained}}$ at equal sensitivity. This single number states how much measurement time the method saves.

Pulls are defined as $(y_i-\hat y_i)$ divided by the square root of their predicted variance. They should be unit Gaussian if $V$ is right. Their widths and tails diagnose lamp drift, detector nonlinearity and depolarization that the covariance ignores. Where the pulls are too wide, $V$ is inflated or given heavy tails, and the effect on $A_{\min}$ is reported rather than hidden.

Baselines

The naive reference point is the Tauc-plot-plus-Urbach-fit analysis common in the bandgap literature. Absorbance is converted to $(\alpha h\nu)^{1/n}$, and the edge and an exponential tail are extrapolated by hand. On synthetic data it is run with the same spectra and noise. A sub-gap band is "detected" when the residual above the fitted tail exceeds three times its bootstrap standard deviation. Beating it means lower $A_{\min}$ and a correct false-positive rate. The latter is expected to be where it fails most.

The strongest existing method is the joint multi-instrument oscillator fit of Ballester et al.. It will be reimplemented with Tauc–Lorentz, Gaussian and Drude terms, fit to the same stacked spectra with the same covariance. Hypotheses are compared by adding a Gaussian oscillator and using the same pseudo-experiment calibration of $q$, so the comparison isolates constraint structure rather than statistics. Both methods get the same number of multistart initializations and the same compute.

For reported numbers, the file gives only their transition energies (1.83–1.85 and 2.38–2.39 eV) and Urbach energy (up to about 336 meV). No reported result was found on Lacuna for a minimum detectable sub-gap absorption amplitude or a false-positive rate for any optical method. The proposal will therefore reproduce Ballester-style fits on its own data to obtain the baseline sensitivity. Beating it means at least a 1.5-fold equivalent exposure gain at matched false-positive rate. It must also avoid the baseline's failure on injected tests where the true sub-gap band is not Gaussian-shaped.

Two ablations isolate the key ingredients. The first removes the pinned host edge; this is the "5C versus 4C" ablation. The second keeps the nonparametric $\varepsilon_2$ grid but drops Kramers–Kronig and energy-conservation constraints. Together they show whether the gain comes from constraints or merely from the flexible representation.

Why not just…?

Why not just use the oscillator fit, since Tauc–Lorentz is already Kramers–Kronig consistent? This is the real threat. For a correctly specified oscillator family, a parametric fit already lives on the constraint manifold, and the constrained fit should match it. The difference appears under misspecification. When the true defect band is asymmetric or overlaps the tail, a Gaussian oscillator can absorb tail curvature and report a spurious detection, or it can miss the band. The synthetic injection study includes such shapes precisely to settle this. If the oscillator baseline matches both sensitivity and false-positive rate on misspecified injections, the nonparametric part of the proposal is unnecessary. The contribution would then shrink to the edge pinning and pseudo-experiment calibration, which could be bolted onto the Ballester approach.

Why not just denoise the spectra with a learned model and fit afterward? ARPESNet shows a noise-to-noise autoencoder can clean Poisson-limited band maps. Denoising, however, cannot add information about $A$. It also makes the covariance of the cleaned spectra unknown, which corrupts any significance computed downstream. The experiments include a denoise-then-oscillator-fit arm. Its false-positive rate under $H_0$ injections is expected to be miscalibrated.

Why not just integrate longer? The $1/\sqrt{N}$ scaling says longer integration always works, and for stable samples it is the honest alternative. The equivalent-exposure factor is designed to answer exactly this question. If it comes out below about 1.5, the method is not worth the complexity. Longer integration also has limits in this field. Narrow-gap oxides and sulfides photocorrode under prolonged illumination, which makes exposure-efficient analysis matter more than for inert samples.

Proposed Experiments

The first stage is synthetic. Forward-model TiO₂- and Cu₃N-like films whose host parameters match the reported gaps and Urbach energies. Inject sub-gap bands with Gaussian, asymmetric and two-component shapes over a logarithmic grid of amplitudes. Add shot noise at several photon budgets, plus non-Gaussian lamp-drift and depolarization errors. Every method is scored on four quantities: $A_{\min}$ at a 5% false-positive rate, the equivalent exposure factor, bias in the recovered amplitude, and correct identification of one versus two defect components.

The second stage is experimental. Prepare a pristine anatase reference, NaBH₄-reduced core-shell TiO₂ following the Ti³⁺ self-doping study, and vacuum-treated brown TiO₂ in the manner of Gao et al.. Each is measured at several deliberately reduced integration times so that the sensitivity curve is traced on real data. The two-component hypothesis is tested against independent evidence of Ti³⁺ and vacancy content, such as annealing series that remove one component preferentially. The decisive check is that the constrained fit's two-band decomposition tracks those treatments while the oscillator fit's does not.

The third stage applies the method to Cu₃N films like those of Ballester et al.. It tests whether their large Urbach energy is a genuine broad tail or a hidden localized band that $q$ can distinguish. The pull distributions are reported for every instrument.

The proposal fails cleanly in either of two cases. The first is if the oscillator baseline matches it on misspecified injections. The second is if the equivalent exposure gain on real TiO₂ spectra falls below 1.5.

References

  1. Measurement of the final states<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mi>ω</mml:mi><mml:msup><mml:mi>π</mml:mi><mml:mn>0</mml:mn></mml:msup></mml:math>,<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mi>ρ</mml:mi><mml:mi>η</mml:mi></mml:math>, and<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mi>ρ</mml:mi><mml:msup><mml:mi>η</mml:mi><mml:mo>′</mml:mo></mml:msup></mml:math>from<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mi>ψ</mml:mi><mml:mo stretchy="false">(</mml:mo><mml:mn>2</mml:mn><mml:mi>S</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:math>electromagnetic decays and<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:msup><mml:mi>e</mml:mi><mml:mo>+</mml:mo></mml:msup><mml:msup><mml:mi>e</mml:mi><mml:mo>−</mml:mo></mml:msup></mml:math>annihilations
  2. New measurement of exclusive decays of the<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:msub><mml:mi>χ</mml:mi><mml:mrow><mml:mi>c</mml:mi><mml:mn>0</mml:mn></mml:mrow></mml:msub></mml:math>and<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:msub><mml:mi>χ</mml:mi><mml:mrow><mml:mi>c</mml:mi><mml:mn>2</mml:mn></mml:mrow></mml:msub></mml:math>to two-meson final states
  3. Study of<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mrow><mml:msup><mml:mrow><mml:mi mathvariant="normal">e</mml:mi></mml:mrow><mml:mrow><mml:mo>+</mml:mo></mml:mrow></mml:msup><mml:msup><mml:mrow><mml:mi mathvariant="normal">e</mml:mi></mml:mrow><mml:mrow><mml:mo>−</mml:mo></mml:mrow></mml:msup><mml:mo stretchy="false">→</mml:mo><mml:mi mathvariant="normal">p</mml:mi><mml:mover accent="true"><mml:mrow><mml:mi mathvariant="normal">p</mml:mi></mml:mrow><mml:mrow><mml:mo accent="true" stretchy="false">¯</mml:mo></mml:mrow></mml:mover><mml:msup><mml:mrow><mml:mi>π</mml:mi></mml:mrow><mml:mrow><mml:mn>0</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math>in the vicinity of the<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"><mml:mrow><mml:mi>ψ</mml:mi><mml:mo stretchy="false">(</mml:mo><mml:mn>3770</mml:mn><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:math>
  4. Measurements of the branching fractions of ψ(3686)→Σ¯0Λ+c.c. and χcJ(J=0,1,2)→ΛΛ¯
  5. Ti3+ Self-Doping of TiO2 Boosts Its Photocatalytic Performance: A Synergistic Mechanism
  6. Comprehensive Optoelectronic Study of Copper Nitride: Dielectric Function and Bandgap Energies
  7. Measurement of the proton-air cross section with Telescope Array’s Middle Drum detector and surface array in hybrid mode
  8. Energy and flux measurements of ultra-high energy cosmic rays observed during the first ANITA flight
  9. An autoencoder for compressing angle-resolved photoemission spectroscopy data
  10. Vacuum-Treated Brown Mesoporous TiO2 Nanospheres with Tailored Defect Structures for Enhanced Photoresponsive Properties