Keeping Hospital Clusters Apart in One-Bit Over-the-Air Federated Learning

Hospitals that want to train a shared medical imaging model without pooling patient data can use federated learning, in which each site trains locally and sends only model updates to a server. A promising way to send those updates wirelessly is over-the-air computation, or AirComp. Every site transmits at the same time on the same frequencies, so the radio channel physically adds the signals and the server receives only the sum. Digital versions such as one-bit AirComp send just the sign of each gradient entry and fit standard radio hardware. Their latency stays constant as the number of sites grows. This convenience has a cost that the medical literature makes visible. Because the server hears only a sum, it can build only one global model. Yet the remedy for single-center bias, where a model learns one hospital's scanners and habits and then fails at other hospitals, is often to give groups of dissimilar hospitals their own models.

We propose a scheme we call cluster-banded digital AirComp. Each hospital picks the nearest of a few broadcast cluster models locally, then transmits its one-bit update on the frequency band reserved for that cluster. Only the parameters that are sensitive to the site go through the cluster bands. The rest of the network is aggregated by a single global vote across all hospitals. The central scientific question is a trade-off. Splitting hospitals into clusters removes bias caused by their differences, but each cluster's "majority vote" then has fewer voters, and channel noise and fading bias grow. We will measure where this trade-off falls on real multi-institutional brain MRI. The target outcome is the worst-performing hospital, because that is exactly where single-center models fail.

Core Claim

Digital AirComp does not force a single global model. The step in which a hospital chooses its cluster needs no information that the air-summed signal destroys. In Multi-Center Federated Learning: Addressing Statistical Heterogeneity, the FeSEM method keeps $K$ model centers. Clients compute their own distance to each center, and the server averages updates within each cluster. The client-side distance step can be kept exactly, because the server broadcasts the $K$ centers downlink at full precision. The server then needs only per-cluster sums, and AirComp can deliver those if each cluster gets its own subcarriers.

This first move is simple, and we do not present it as the contribution. The contribution is to characterize and resolve the cost it creates. One-Bit Over-the-Air Aggregation shows that the learning bias caused by imperfect channel information shrinks roughly as $\mathcal{O}(1/\sqrt{n})$ in the number of voters $n$. Splitting 32 hospitals into $K$ clusters shrinks each vote to about $32/K$ voters. We model the error in cluster $c$ as

$$ \text{err}_c \approx \frac{a}{\sqrt{n_c}} + b\,\Delta_c(K), $$

where $n_c$ is the number of hospitals in cluster $c$, $a$ scales with channel-estimation error and noise (the one-bit analysis), and $\Delta_c(K)$ is the spread of the true gradients within the cluster. That spread falls as $K$ rises. The model predicts an optimal $K$ that shifts toward fewer clusters at low signal-to-noise ratio.

Our design escapes much of this tension with a split. Parameters that carry hospital-invariant structure, such as the encoder of a 3D U-Net, keep the full 32-voter global vote. Only a small set of parameters that are sensitive to scanners and sites uses the cluster bands. Candidate sets are the normalization layers, or those layers plus the final decoder block. The cluster bands then need little bandwidth, and the small per-cluster votes affect only a small part of the network.

Research Program

Setting. The testbed is the Federated Tumor Segmentation (FeTS) data, partitioned by institution. Towards fair decentralized benchmarking of healthcare AI algorithms with the FeTS challenge and The FeTS Challenge describe this set as multi-parametric brain MRI from 32 international institutions, drawn from BraTS 2020 and 2021. The FeTS papers matter because they motivate the problem. Global Dice is often above 0.9, yet particular sites fail badly: edema is mislabeled as active tumor, small enhancing foci are missed, and necrotic-core boundaries are wrong. This is single-center overfitting that surfaces under federation, and a single global model does not fix it.

Channel. We simulate the channel with the OBDA design, which is the method we reuse. OBDA sends one-bit signs as BPSK symbols on OFDM subcarriers. OFDM splits a wideband channel into many narrow parallel subcarriers, and BPSK sends one bit per symbol as a phase flip. OBDA uses truncated channel inversion, under Rayleigh fading with controllable channel-estimation error and signal-to-noise ratios from 0 to 20 dB. Cluster-Based Cooperative Digital Over-the-Air Aggregation shows that alignment using phase correction alone can approach ideal convergence. We include it as a variant that is friendlier to hardware.

What we build. We build the cluster-banded scheme with a pluggable choice of which parameters are clustered. We also add a clustering step that uses only signals the server can actually obtain. Hospitals compute their distances to the centers locally. The server learns cluster sizes through a one-bit, one-hot count on a control band, and needs no per-site identity. We also add sign-with-error-feedback, because updates shrink near convergence. An Autoencoder-Based Constellation Design for AirComp warns that fixed quantization loses these small updates unless the gain is adapted, and that study was run only on CIFAR-10 with 8 clients.

What we analyze. First, we trace the empirical optimal $K$ against signal-to-noise ratio and against channel-estimation error, and test whether it follows the shape the error model predicts. Second, we check which layers actually differ systematically across institutions. We cluster sites by their locally computed distances and test whether the clusters line up with metadata on scanner vendor or field strength where the data provide it. Third, we check whether one-bit aggregation specifically harms the hard tumor sub-regions. The BRATS benchmark reports that top algorithms reach only the high 50s to low 60s in active-core Dice even at full precision.

Baselines

The ideal reference is FedAvg over orthogonal, full-precision, error-free links: one global model with no channel effects. The naive reference point is the "do nothing" option, where each hospital trains only on its own data. Its worst-site Dice measures how much single-center training costs on this data.

The strongest existing method for heterogeneity is FeSEM (Multi-Center FL), run with full-precision orthogonal uploads. The paper reports 90.3% micro-accuracy for FeSEM with $K=4$, against 84.9% for FedAvg on FEMNIST. We found no reported result on Lacuna for FeSEM on FeTS or BraTS, so we run it ourselves as the performance ceiling for clustering.

The strongest existing digital AirComp method is single-model OBDA (One-Bit Over-the-Air Aggregation). We found no reported result on Lacuna for OBDA or any digital AirComp scheme on FeTS or BraTS segmentation. The reported CIFAR-10 claims are constant latency from 10 to 1000 devices, and accuracy near the error-free ideal at 15 dB for the learned constellations.

Two ablations isolate our key ingredients. The first is naive cluster-banded OBDA, which sends all parameters on cluster bands. It shows whether the split into global and cluster parameters matters. The second is cluster-banded OBDA with random cluster assignment, which shows whether the benefit comes from grouping hospitals by similarity or merely from extra bandwidth.

All methods share the same 3D U-Net, the same institution split, the same number of communication rounds, and the same learning-rate search budget per method. They also share the same total uplink subcarrier budget: the global band and the cluster bands together use no more bandwidth than single-model OBDA uses at the same latency.

Beating OBDA means higher worst-decile per-institution Dice, and higher Dice on enhancing tumor, at equal bandwidth and latency, across seeds and signal-to-noise levels. The goal against FeSEM is to recover most of its worst-site advantage over FedAvg while keeping AirComp's constant latency.

Why not just…?

Why not just send updates on separate channels (orthogonal access) and run FeSEM directly? For 32 hospitals this is a real threat. The latency penalty grows linearly with the number of sites (OBDA), and at $K=32$ the penalty may be tolerable. Many hospitals also have wired links. We will not argue around this. We report measured round latency and accuracy for orthogonal FeSEM against our scheme at 32 sites. We then scale the number of simulated sites, either by splitting sites or by adding mobile or edge imaging units. Our claim is limited to the regime where the latency gap is large, which is shared wireless spectrum with many participants.

Why not just train one global OBDA model and fine-tune it locally at each hospital? This is also a strong competitor. Local fine-tuning needs no extra bandwidth and handles site shift directly. We run it with the same fine-tuning budget. If it matches cluster-banded aggregation on worst-site Dice, the value of clustering lies elsewhere, if anywhere. It could still help small hospitals, whose local data are too scarce for fine-tuning to work. We test this by stratifying results by site size.

Why not just keep normalization layers local and share everything else, with no clustering? This is the limiting case of our split with $K$ equal to the number of sites. The cluster bands then carry nothing, and each hospital fits its own normalization layers on its own data. Sweeping $K$ from 1 to 32 includes this case. If $K=32$ wins, the lesson is that site-specific layers need no cross-site voting, which is still a useful negative result.

Why not just use multi-bit learned constellations instead of one-bit signs? The learned-constellation work (Autoencoder-Based Constellation Design) reports that the number of distinct sum points explodes as clients and bits grow; one example is 121 sums for 8 clients at 4 bits. Splitting hospitals into clusters actually eases that explosion, because each cluster has fewer transmitters. We therefore run a secondary arm with a 2-bit learned constellation per cluster band.

Decisive Checks

Three results would settle the proposal. First, at a moderate signal-to-noise ratio of 10 dB, cluster-banded OBDA with the split should raise worst-decile institutional Dice above single-model OBDA. This must hold at equal bandwidth and must hold for real clustering but not random clustering. Second, the empirical optimal $K$ should fall as channel error rises, as the error model predicts. If it does not, the model of the trade-off is wrong. Third, the split should beat naive all-parameter banding, most clearly at 0 dB, where small votes hurt most.

FeTS reference labels contain about 10.4% annotation errors (FeTS). Worst-site gains could therefore reflect label noise rather than real improvement. We will report every site-level result both on all labels and on the subset of labels that passed screening.