Forward-Folding Thermal Smearing Out of Thermogravimetric Kinetics

Thermogravimetric analysis (TGA) heats a small sample and records its mass as it decomposes. Chemists then fit a rate law to the curve to obtain an activation energy, the energy barrier that controls how fast a material breaks down. The fitted barrier is used to design pyrolysis reactors, boilers and waste-plastic recycling. The difficulty is that the sample never sits at the temperature the instrument reports. Heat has to cross the crucible, the gas layer and the inside of each particle. Endothermic decomposition also cools the sample as it reacts. Each true reaction peak is therefore smeared and shifted toward higher apparent temperatures, by amounts that change with heating rate, sample mass and particle size.

Electron–positron collider physics faces a structurally similar problem and handles it in a disciplined way. Before colliding, the electrons radiate photons, called initial state radiation. Each collision therefore happens at a spread of energies below the nominal beam energy, which smears the measured resonance lineshape. Physicists do not try to invert the smeared data. They compute the radiation kernel from theory, independently of the data. They then fold a candidate "bare" lineshape through that kernel and fit the bare parameters jointly across every energy point of a scan. We propose to apply that same procedure to TGA. The procedure has three parts: calibrate a thermal smearing kernel independently, fold the bare kinetics through it, and fit one shared set of parameters across a scan of heating rates and particle sizes.

Core Claim

Apparent kinetic parameters in TGA drift with experimental conditions, and much of that drift is instrumental and transport smearing rather than chemistry. A forward-folding fit should remove it. In this fit, a single set of bare kinetic parameters is passed through a separately calibrated, condition-dependent thermal kernel and fit at once to all runs. The test is concrete. Under current methods, the activation energy of a single feedstock moves with particle size and carrier gas flow. Corncob, for example, gives 64 to 80 kJ/mol across such conditions (Assessing the Effects of Different Process Parameters on the Pyrolysis Behaviors and Thermal Dynamics of Corncob Fractions). Under the forward-folding fit, the bare parameters extracted from each condition separately should agree within their uncertainties. The folded model should also predict DTG curves at heating rates and particle sizes held out of the fit. If neither happens, the claim is wrong.

The approach is modeled on two collider analyses that supply the method. The BESII ψ(3770) scan fit a Breit–Wigner lineshape, folded through the radiation kernel and vacuum polarization, simultaneously across 68 energy points (Precision measurements of the mass, the widths of ψ(3770)…). The BESII R-value analysis computed radiative corrections to $\mathcal{O}(\alpha^3)$. It also iterated, because its detection efficiency depended on the very lineshape being measured (R value measurements for e+e− annihilation at 2.60, 3.07 and 3.65 GeV).

The same ψ(3770) paper also sets a constraint. Its fitted width disagrees with coupled-channel predictions by more than 7σ, and it leaves an unexplained dip near 3.80 GeV. Folding is only as good as the bare model one folds. We carry that lesson over: any systematic residual that remains after folding is reported as evidence of missing chemistry, not absorbed into the kernel.

Research Program

The forward model has two pieces. The first is a lumped heat balance that connects the programmed furnace temperature $T_f(t)$ to the mean sample temperature $T_s(t)$:

$$\frac{dT_s}{dt} = \frac{T_f - T_s}{\tau} - \frac{\Delta H}{c}\,\frac{d\alpha}{dt}.$$

Here $\tau$ is a heat-transfer time constant, $\Delta H$ is the reaction enthalpy per unit mass, $c$ is the specific heat, and $\alpha$ is the conversion. The second term is the self-cooling effect of an endothermic reaction.

The second piece handles temperature gradients inside particles. The observed rate is modeled as an average of the bare rate over a one-sided spread of local temperatures:

$$\frac{d\alpha}{dt}\Big|_{\text{obs}} = \int K(\Delta T;\,\beta, d, Q)\; r_{\text{bare}}\big(T_s - \Delta T, \alpha\big)\, d\Delta T.$$

In this expression, $K$ is the kernel. Its width depends on heating rate $\beta$, particle size $d$ and gas flow $Q$. The function $r_{\text{bare}}(T,\alpha) = A e^{-E_a/RT} f(\alpha)$ is the bare rate, where $A$ is the pre-exponential factor, $E_a$ the activation energy and $f(\alpha)$ the reaction model. The kernel is one-sided because, during heating, interior regions can only lag the surface, never lead it. This mirrors the radiation kernel, which can only lower the collision energy.

The kernel parameters, $\tau$ and the width and tail of $K$, are calibrated without using the sample of interest. Calibration uses reference events with sharp, known transitions measured on the same instrument and crucible. Examples are melting standards observed in the heat-flow channel of a combined TGA and DSC (differential scanning calorimetry, which records heat flow), and Curie-point standards. Calibration also uses inert particles of matched size. The DSC channel provides $\Delta H$ directly. This independence is the key ingredient. It prevents the kernel from soaking up kinetic misfit, and the kernel's calibration uncertainty is carried through the fit as a systematic error, as collider analyses do.

The bare parameters $(E_a, A, f)$ for each reaction stage are then fit with a joint likelihood over all runs in a scan. One parameter set must explain every heating rate and particle size. Multi-component materials receive one bare term per component. Kinetic compensation means that different $(E_a, A)$ pairs can fit one peak equally well. A joint fit across heating rates breaks much of this degeneracy, because the pairs that compensate at one heating rate do not compensate at another. We report the full posterior rather than a single point estimate, so that any degeneracy that survives is visible.

Baselines

The naive reference point is Coats–Redfern fitting of each run separately, using the reported furnace temperature. It is the default in the literature this proposal targets, from co-firing of cattle manure (Combustion characteristics of cattle manure and pulverized coal co-firing…) to densified biomass (Effect of densification pretreatment on combustion…). On corncob it yields 64 to 80 kJ/mol across conditions (corncob study). To beat it, our method must shrink the spread of $E_a$ across conditions to within its stated uncertainty.

The strongest existing method in the file is the CPVC pipeline. It combines isoconversional Flynn–Wall–Ozawa analysis (which estimates $E_a$ at fixed conversion from several heating rates) with global optimization by Shuffled Complex Evolution, applied to runs at 10, 20, 30 and 60 K/min (Thermal Decomposition Mechanism and Kinetics Study of Plastic Waste CPVC). It reports a Stage II $E_a$ of 246.07 kJ/mol from Flynn–Wall–Ozawa and 332.81 kJ/mol after optimization, with prediction $R^2$ up to 0.97.

We will run that pipeline and ours on identical CPVC runs, with identical stage boundaries and the same optimizer evaluation budget. Beating it means three things together:

  • matching or exceeding its $R^2$ on held-out heating rates;
  • shrinking the 86 kJ/mol disagreement between the two estimates;
  • reporting parameters that do not drift when the 60 K/min run is dropped.

Two ablations isolate the key ingredient. The first replaces the calibrated kernel with a constant temperature shift fitted per run, which is the TGA analogue of applying a single multiplicative radiative-correction factor. The second keeps the kernel but lets its parameters float freely in the fit instead of fixing them by calibration. If the floating-kernel variant does as well as the calibrated one, independent calibration is not the source of the gain.

Why not just…?

Why not just run at low heating rates with tiny samples? This is the strongest competitor. Small masses and slow heating do reduce thermal lag. However, they give up the spread of heating rates that breaks kinetic compensation. They also do not remove gradients inside particles for materials that must be tested at realistic particle sizes. The corncob study shows mass loss itself changing from 47.79% to 77.23% between 5 and 20 °C/min (corncob study), so slow runs do not represent reactor conditions. We test this alternative directly by including a slow, small-mass run as a "near-bare" reference. If per-run Coats–Redfern on that run already matches our folded parameters, and the folded fit adds no predictive value at high heating rates, the method is unnecessary and we will say so.

Why not just use isoconversional methods across heating rates? These methods also exploit several heating rates. But they read temperature at fixed conversion, so a lag that grows with heating rate enters their slopes directly. The CPVC gap between 246 and 333 kJ/mol (CPVC study) is the kind of disagreement smearing would produce. We will apply Flynn–Wall–Ozawa to synthetic curves generated with known bare kinetics and known lag, which shows how much bias the lag alone induces.

Why not just fit Gaussian or Fraser–Suzuki peaks, or train a regressor on raw curves? Peak shapes are flexible enough to fit almost anything, but their parameters are not kinetic constants. Regressors such as the partial least squares models of the tobacco study predict composition well, with $R^2$ of 0.87 to 0.93. They do not extrapolate to unseen heating rates, which is the test that matters here. We include a peak-fit baseline in the held-out-condition prediction test.

Proposed Experiments

The first stage is synthetic recovery. We simulate DTG curves from known bare kinetics folded through known kernels, spanning a range of heating rates, particle sizes and endothermicities. We then measure how well each method recovers $E_a$, $A$ and $f$ in terms of bias and coverage of the true values. No reported result was found on Lacuna for kernel-based TGA recovery, so this benchmark is new.

The second stage uses real data with a replicated design. The design reproduces the corncob grid of three heating rates, three gas flows and four particle sizes, together with the CPVC four-rate series. Calibration standards are run on the same instrument. The raw curves from the cited studies are not available in the file, so these measurements are new. Their conditions are chosen so that the published numbers serve as sanity checks.

The decisive checks are three. The first is invariance: per-condition fits of $E_a$ agree within uncertainty under folding but not under Coats–Redfern. The second is prediction: we fit on two particle sizes and two heating rates, then predict the held-out DTG with lower residuals than every baseline. The third is calibration dependence: the calibrated-kernel model beats the floating-kernel ablation.

Residual structure that survives folding is treated as a signal of missing chemistry. In biomass mixtures, cellulose–lignin interactions are expected to appear this way (Components Interaction of Cotton Stalk…). This parallels how the ψ(3770) dip points to physics missing from the lineshape model.