Do EEG Microstates Carry Clinical Information Beyond the Power Spectrum?

Scalp EEG can be summarized as a sequence of a few recurring "microstates": brief scalp voltage patterns that each hold steady for roughly 60 to 120 ms before the brain switches to another. Clinical studies report that the timing of these states changes in Alzheimer's disease and many other disorders. One microstate pipeline has also reached 94% accuracy for detecting dementia across six cohorts from ten countries. Dementia, however, also slows the EEG and changes the slope of its background "1/f" noise. Microstates are extracted at the moments when signal strength across the scalp peaks, and those moments depend on which frequencies dominate the signal. The reported microstate changes could therefore be a re-description of spectral slowing rather than evidence of reorganized brain networks. If so, models built on them would carry along every site-specific difference in amplifiers, filters, and patient age that shapes the spectrum.

This note proposes a direct test, followed by a method that depends on how the test comes out. For each recording we generate surrogate signals. A surrogate keeps the recording's full multichannel spectrum, meaning each channel's power at every frequency and the coupling between every pair of channels, but scrambles its temporal ordering. We then measure how much of each clinical microstate effect the surrogate reproduces. Only the part that survives, which we call excess microstate structure, is credited to microstate dynamics. That part is combined with individualized spectral features and judged under leave-one-site-out evaluation. Leave-one-site-out is the setting that actually matters for clinics, and to our knowledge it has not been reported for microstate dementia classifiers.

Core Claim

We claim that microstate features as currently computed are largely, though perhaps not entirely, determined by spectral composition. We further claim that the residual, spectrum-independent part transfers across recording sites better than the raw microstate parameters do. The proposal is built so that the first claim can be falsified cheaply. If surrogates reproduce the clinical effects, that is itself a substantive result for the field. If they do not, the excess features become a portable biomarker that can be interpreted directly.

Why this gap, and what prior work establishes

Two lines of work motivate the question.

Changes in the left temporal microstate are a sign of cognitive decline in patients with Alzheimer's disease clustered microstates separately within delta, theta, alpha, and beta bands in a 19-channel Nordic cohort of 369 people. Microstate A was elevated in delta and theta, and there were no group differences in alpha. Accuracy was modest: 69.8% for controls vs. AD and 58.7% for controls vs. MCI. That study used fixed band edges. It did not model the aperiodic background and did not test transfer across datasets.

Transforming Brainwaves into Language: EEG Microstates Meet Text Embedding Models for Dementia Detection did the opposite. It converted broadband microstate sequences into text, embedded them with a commercial embedding API, and reached 94.31% accuracy with a Brier score of 0.0464 on 1,001 participants (715 controls, 286 AD) pooled from CAUEEG, PEARL-Neuro, DS004504, CHBMP, BrainLat, and TUAB. It discards frequency information entirely. Its high accuracy is a pooled-cohort figure, and the file does not tell us whether test subjects came from sites seen in training. When cohorts contribute very different proportions of patients, a pooled classifier can score well by recognizing the site.

Three results constrain the design.

The aperiodic work in The development of aperiodic neural activity in the human brain separated oscillatory peaks from the 1/f background using IRASA (irregular-resampling auto-spectral analysis, a way to split the spectrum into rhythmic peaks and a smooth noise floor). It showed that the background slope shifts systematically with age. Aperiodic and oscillatory systems underpinning human domain-general cognition showed that aperiodic broadband power, not band power, carried decodable signal across cognitive tasks. Taken together, these imply that age and medication differences between sites will move the spectrum, and with it every microstate statistic.

Effects of Obstructive Sleep Apnea on Cognition: An Analysis of Electroencephalography Microstates and Alpha Peak Frequency reported microstate changes alongside slowing of the individual alpha peak, but treated the two as parallel measurements. It never asked whether one explains the other.

Finally, Amplifying Pathological Detection in EEG Signaling Pathways through Cross-Dataset Transfer Learning documents how sharply cross-site shift hurts. A TCN pre-trained on TUAB reached only 0.7370 balanced accuracy on the South Asian NMT dataset. The method we reuse for microstate extraction itself comes from the modified k-means and back-fitting procedures in Microstate EEGlab toolbox: An introductory guide.

Research Program

The work has three components.

1. Spectral normalization before clustering. For each subject we fit the aperiodic component per channel with IRASA and remove it by filtering each channel with the inverse of its fitted 1/f curve. We then define bands relative to the individual alpha peak frequency rather than at fixed edges, so that a slowed alpha rhythm is not mislabeled as theta. Microstates are extracted within each band.

To stay channel-independent across 19- to 128-channel montages, group templates are learned on a common 19-electrode subset. They are then back-fitted to each recording after interpolating the templates, not the data, onto that recording's montage.

2. Surrogate decomposition. For each recording $x$, we generate $S$ multivariate phase-randomized surrogates $\tilde{x}_s$. Each surrogate adds the same random phase to every channel at a given frequency, which preserves the cross-spectral matrix and destroys temporal ordering and nonlinear structure. For any microstate feature $m$ (duration, occurrence, coverage, or a transition probability), the excess feature is

$$\Delta m(x) = m(x) - \frac{1}{S}\sum_{s=1}^{S} m(\tilde{x}_s),$$

where $m(\cdot)$ is computed with identical templates and settings on the real and surrogate signals. A clinical effect that appears in $m$ but vanishes in $\Delta m$ was spectral. An effect that survives in $\Delta m$ reflects sequence structure that the spectrum cannot produce.

3. Analyses and classifiers. We first quantify the fraction of each published group effect that surrogates reproduce. The primary targets are the theta Microstate A elevation and the Microstate D reduction.

We then train compact, interpretable classifiers: logistic regression and gradient-boosted trees on a few dozen features. These are trained on spectral features alone, on spectral plus raw microstate features, and on spectral plus excess microstate features. Every comparison is scored under leave-one-site-out evaluation.

Baselines

The naive reference point is a classifier that predicts each held-out site's majority class. This is reported alongside balanced accuracy, because class proportions differ across cohorts. We also train a site-prediction probe on each feature set. If a feature set predicts site well, that is a warning that its clinical accuracy may be borrowed from site identity.

The strongest competitor on the question we are asking is a pure spectral model. It uses relative band power in individualized bands, the alpha peak frequency, and the aperiodic exponent and offset per region, fed to the same logistic regression and boosted trees. It is the strongest competitor because it encodes exactly what we suspect microstates are re-describing, at negligible cost. It gets the same subjects, folds, preprocessing, and hyperparameter search budget as our model. No reported result found on Lacuna for this baseline on the multi-country dementia benchmark, so we establish it ourselves. Beating it means a site-level bootstrap confidence interval on the gain in held-out AUROC that excludes zero, averaged over held-out sites, with the margin pre-registered.

The strongest existing microstate method is the text-embedding pipeline of Nguyen et al., with 94.31% accuracy and a 0.0464 Brier score as reported in Transforming Brainwaves into Language. We rerun it on our exact splits in two forms: with the original embedding model, and with a recurrent network on raw symbol sequences that removes the proprietary dependency. We report both its pooled-split number, to check that we reproduce theirs, and its leave-one-site-out number. Beating it means higher held-out balanced accuracy and lower Brier score at equal or lower site-prediction accuracy. We do not need to match 94.31% on a pooled split.

For a high-capacity reference, we fine-tune CodeBrain on the same folds, restricted to the shared 19 channels, with the same tuning budget in trials. No reported result found on Lacuna for CodeBrain on dementia detection.

Ablations isolate the key ingredient. They are: raw versus excess microstate features; with versus without aperiodic whitening; individualized versus fixed band edges, the latter as in Changes in the left temporal microstate; and broadband versus band-specific microstates.

Why not just…?

Why not just use spectral features and skip microstates? This is the real threat, and the proposal treats it as the null hypothesis rather than a strawman. Sub-band analyses elsewhere beat full-spectrum ones by large margins, for example 86.5% vs. 59.5% for MCI in a small fMRI study (Resting-State Multi-Spectrum Functional Connectivity Networks). That suggests spectral detail alone may carry most of the signal. If the spectral-plus-excess model fails to beat the spectral-only model under leave-one-site-out evaluation, we will report that microstates add nothing portable for dementia. That conclusion is itself useful.

Why not just append alpha peak and aperiodic slope as extra columns to standard broadband microstate features? This is what the sleep apnea study effectively did (Effects of Obstructive Sleep Apnea on Cognition). A flexible classifier given both could learn to discount the spectral part of the microstate features. It cannot do this reliably, though, when the relation between spectrum and microstates differs by site, which is precisely the cross-site setting. The "spectral plus raw microstate" arm runs this alternative directly. If it matches the excess-feature arm on held-out sites, the surrogate step is unnecessary for prediction and remains useful only for interpretation.

Why not just fine-tune a foundation model? CodeBrain is robust to dropping channels, but its fine-tuned representations mix time and frequency information and cannot be read as durations or transition probabilities. The cross-subject collapse from 94.5% to 31.3% reported in GNN4EEG also warns that high-capacity models readily learn individual or site signatures. The CodeBrain arm, scored together with the site-prediction probe, will show whether its accuracy holds once the held-out site is truly unseen.

Proposed Experiments

The primary dataset is the six-cohort dementia benchmark used by Nguyen et al. Before training, we tabulate label composition per site. Any site that contributes a single class is used only as a test site, where it measures false-positive rate on controls or sensitivity on patients.

The secondary transfer test is abnormality detection, trained on TUAB and tested on NMT. There the reference is the 0.7370 balanced accuracy of the pre-trained TCN in Amplifying Pathological Detection. This tests whether excess microstate features help beyond dementia.

Metrics are balanced accuracy, AUROC, and Brier score per held-out site, plus site-prediction accuracy from each feature set.

The first decisive check is the surrogate reproduction fraction for the theta Microstate A effect. Above roughly 80%, the left-temporal-microstate interpretation becomes a spectral one.

The second is the sign and confidence interval of the held-out AUROC gain of excess features over spectral features.

The third is a sanity test of the surrogate machinery. Vigilance is known to modulate microstate sequences (Evidence for modulation of EEG microstate sequence by vigilance level). Where vigilance labels exist, we check that $\Delta m$ still tracks them. Otherwise the surrogates may be removing genuine sequence structure, and a null clinical result would be uninformative.