NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Counting What TOF Buys: Count-Equivalent Evaluation of Learned PET Reconstruction from Few Patients

A PET scanner detects pairs of gamma photons that fly out in opposite directions from each positron annihilation. Time-of-flight (TOF) scanners also measure the tiny difference in the two photons' arrival times. That difference places the event within a few centimetres along the line joining the two detectors, instead of anywhere on it. The established effect is statistical. TOF reduces noise the way collecting more photons would. It lets a 1-minute TOF scan match a 3-minute non-TOF scan for finding lesions in heavy patients (Surti et al.). Deep networks for low-dose PET now sit on top of this physics. They are trained on very small cohorts, such as 9 patients in 200x Low-dose PET, and scored by pixel fidelity, meaning peak signal-to-noise ratio (PSNR) and structural similarity (SSIM). Pixel fidelity cannot tell us whether a network kept TOF's photon-count advantage or smoothed it away along with the noise.

This proposal does two things. First, it scores every reconstruction by equivalent counts: how many photons a standard TOF reconstruction would need to detect small lesions equally well. Second, it trains networks from few patients using two transformations of the raw per-event data (list-mode data, the stream of individual detected events). Randomly discarding events simulates a lower dose. Adding random timing jitter simulates a slower scanner. Both are close to exact. Together they turn a handful of patients into a controlled grid of dose and timing conditions. The central question is whether a learned reconstruction gives a count gain that is real, survives changes in timing hardware, and can be measured with honest error bars when only a few patients exist.

Core Claim

The claim has two parts, one about evaluation and one about training.

The evaluation part is that learned low-count reconstructions should be reported in units of equivalent counts, measured by a model observer. A model observer is a statistical detector that stands in for a radiologist. We use the channelized Hotelling observer, a linear detector applied to a small set of frequency-band features. Its detectability index is written $d'$. For a method $M$ run on $N$ recorded coincidences, define the count-equivalence ratio as

$$ \rho_M(N) = \frac{N_{\mathrm{eq}}}{N}, \qquad d'_{\mathrm{TOF\text{-}OSEM}}(N_{\mathrm{eq}}) = d'_M(N). $$

Here TOF-OSEM is the standard iterative TOF reconstruction, with its smoothing tuned for the best $d'$ at each count level. $N_{\mathrm{eq}}$ is the count level at which it matches method $M$. A ratio $\rho_M > 1$ means the network adds detection information beyond the TOF reference. A ratio $\rho_M < 1$ means the network removes information, however clean its images look.

The same unit also expresses what TOF itself is worth. A reconstruction with timing kernel width $\Delta x = c\Delta t/2$, imaging an object of diameter $D$, has its noise variance reduced by roughly

$$ G_{\mathrm{TOF}} \approx \frac{D}{\Delta x}. $$

This follows from the standard analytic argument: each event's back-projection is confined to a Gaussian of width $\Delta x$ instead of the whole chord. The formula does not hold for nonlinear learned reconstructions, so it has to be measured.

The training part is that list-mode data admits two nearly exact transformations. Keeping each event independently with probability $p$ produces a valid lower-count dataset. Adding independent Gaussian noise to each $\Delta t$ turns a timing resolution $\tau$ into $\sqrt{\tau^2+\sigma^2}$. From $K$ patients we can therefore generate $K$ patients at any (count, worse-timing) pair. We predict that a network trained across this grid, and told the timing width as an input, keeps $\rho_M > 1$ on timing resolutions and patients it never saw. We predict that a network trained at a single condition loses its gain, or falls below $\rho=1$, when the timing changes.

Research Program

The work has three components. Each can be tested alone.

Count-equivalence measurement. We use the hybrid-lesion design of Surti et al., which placed simulated 10-mm spheres into 100 real patient backgrounds. We extend it by inserting simulated sub-centimetre lesions of 4 to 10 mm into list-mode data, event by event. Each insertion uses the correct attenuation, the correct timing distribution, and a known location. Lesion-absent copies of the same data serve as controls. This produces many detection trials per patient.

The study also has a methodological point about small samples. Lesion trials within one patient are not independent. We therefore compute confidence intervals on $d'$ and $\rho$ with a patient-level bootstrap. We report how much narrower naive lesion-level intervals are. This gap is the quantity that small-cohort PET papers currently leave unstated.

Detection is inherently a low-count problem. As the physics literature shows, from Telescope Array anisotropy to EXO-200, sensitivity is bounded by Poisson fluctuation rather than by instrument precision. We borrow that framing: equivalent counts is a sensitivity statement, not a statement about image appearance.

Grid-augmented reconstruction. The reconstruction backbone is the list-mode unrolled primal-dual network of LMPDnet. "Unrolled" means the network mimics a fixed number of steps of an iterative solver. LMPDnet updates each event with a small fully connected network and projects on the fly rather than storing a large system matrix, which drops memory from 87 GB to about 20 GB. We choose it because it keeps the per-event timing information that our augmentation needs. We add one change: the TOF kernel width, and hence $\sigma$, becomes a conditioning input.

Training draws a random discard probability $p$ and a random jitter $\sigma$ for every example. We run this with a deliberately small number of training patients, $K \in \{3, 6, 9, 20\}$, and plot data-scaling curves.

Transfer across timing. We hold out timing conditions that the network never sees. These include jitter levels outside the training range and, in simulation, sharper timing. Orehar et al. suggest that the sub-100 ps regime of 75–200 ps changes scanner geometry trade-offs, so we simulate it with BrainWeb and GATE/CASTOR, the Monte Carlo and reconstruction tools used in that work.

This setup is the list-mode counterpart of the scanner-shift problem addressed at the image level by PETITE. PETITE adapts under 1% of a network's parameters per scanner. It works only on finished images and never models timing. Laforest et al. likewise show that TOF and non-TOF scanners converge differently. They harmonized them only by tuning filters on phantoms.

Baselines

Naive reference: tuned TOF-OSEM. The "do nothing new" reference is list-mode TOF-OSEM, the standard iterative reconstruction. We tune its iteration count and Gaussian post-filter per count level to maximise observer $d'$, not PSNR. This makes it the denominator of $\rho$, and by construction it has $\rho=1$. Tuning for detection matters. LMPDnet reports LM-OSEM at 23.83 dB PSNR against 32.17 dB for its own network on brain data, but that OSEM was not tuned for detection, and a PSNR gap of that size may shrink sharply in $d'$.

Strongest existing method: LMPDnet trained at one condition. The strongest competitor is LMPDnet exactly as published: trained at the native timing and a single dose. It is the only method in the file that reconstructs directly from TOF list-mode data, and it reports 32.17 dB PSNR and 0.986 SSIM, well above FastPET at 28.32 dB. We retrain it on the same $K$ patients with the same compute and the same number of hyperparameter trials as our model. Beating it means two things. First, higher $\rho$ with non-overlapping patient-bootstrap intervals on held-out timing conditions. Second, no loss at the native condition.

Image-domain comparisons: FlowPET and PETITE. We include the image-domain generative model FlowPET. It is built to preserve faint lesions and reports 36.35 dB PSNR and 0.9811 SSIM on 1% pediatric scans. It works on binned data, so it has no access to per-event timing. We also include PETITE-style parameter-efficient adaptation to each timing condition, using the same target-condition data budget. Absolute detectability numbers exist for neither method: no reported model-observer or AROC result was found on Lacuna for any of these methods. Surti et al. report only significance ($P<0.01$), not absolute AROC.

Ablations isolating the key ingredient. Two ablations isolate the idea. One uses discarding only, with no jitter, and tests whether timing diversity matters beyond count diversity. The other uses both augmentations but hides the timing-width input from the network, and tests whether conditioning matters.

Why not just…?

Why not just report PSNR and SSIM, as everyone does? Reconstructions that smooth heavily raise PSNR while erasing small lesions. FlowPET shows exactly this: diffusion baselines that look reasonable still lose lesion uptake ratios. We will compute the rank correlation between PSNR and $\rho$ across all methods and conditions. If PSNR ranks methods the same way as equivalent counts, the evaluation half of the proposal is unnecessary, and we will say so.

Why not just use the analytic TOF gain $D/\Delta x$ to predict performance? That formula assumes linear reconstruction with Gaussian kernels. A trained network can amplify the gain, ignore it, or trade it for smoothness. Measuring $\rho$ for learned methods at several timing resolutions against $G_{\mathrm{TOF}}$ directly tests whether the formula still predicts anything.

Why not just gather more patients, for example the 206 UDPET brain scans FlowPET used? This is the real threat to the augmentation idea. If pooled real data beats the augmented grid, augmentation is only a stopgap. The scaling curve over $K$ settles it. We compare the $K=9$ augmented model against an unaugmented model trained on the largest list-mode cohort we can obtain. If UDPET or other data are available only as images, we will report that as a limit on this comparison. We will not use pixel-domain proxies, because they would bias the comparison. Even if more data wins, the timing jitter still generates timing conditions that no existing cohort contains.

Why not just fine-tune per scanner with PETITE? PETITE needs target-scanner data and adapts images after reconstruction. It improved PSNR by 1.039 dB over adapter tuning, but no timing-shift result is reported. We run it as a baseline with equal target data. If it matches grid augmentation on $\rho$, the cheaper route wins.

Proposed Experiments

Simulation. BrainWeb brain phantoms are simulated in GATE at timing resolutions of 75, 200, 400 and 550 ps and count fractions from 100% down to 0.5%. The simulator gives ground-truth equivalence curves, because we can simulate TOF-OSEM at any count level. Inserted lesions of 4–10 mm give $d'$ and $\rho$ estimates with patient-level bootstrap intervals. The NEMA NU-2 phantom then provides contrast recovery and background variability as a check on quantitative accuracy, following Laforest et al..

Clinical list-mode data. The same protocol is applied to clinical list-mode brain data of the kind LMPDnet used, from a Biograph Vision Quadra scanner, with lesions inserted in hybrid fashion. We add a high-BMI stratum where torso list-mode data exist, because Surti et al. found the TOF benefit concentrated there.

Decisive checks. Four results decide the outcome. First, whether the grid-augmented network holds $\rho>1$ on held-out timing conditions where single-condition LMPDnet falls below it. Second, whether its false-positive detection rate on lesion-absent images stays at the TOF-OSEM level, which rules out invented lesions. Third, whether patient-level and lesion-level confidence intervals differ enough to change conclusions at $K\le 9$. Fourth, whether $\rho$ at $K=9$ with augmentation approaches $\rho$ at $K=20$ without it.

A negative result on the first check would still be useful: learned TOF reconstructions do not carry their count gain across hardware.