Screening models in medicine are tuned to rarely miss a sick patient. The usual recipe is to lower the decision threshold until measured sensitivity, the fraction of truly sick patients the model flags, reaches a target such as 95%. That measurement is only as good as the labels it is computed against, and at scale those labels are almost never expert chart reviews. They are diagnoses pulled out of radiology reports and discharge summaries by an automated extractor, or they are billing codes. Extraction errors are not random. They concentrate in hedged language ("cannot exclude a small effusion"), in sparse documentation, and in rare findings. Those are the same places where a screening model trained on the extracted labels also scores patients low. The model and the label then agree that a patient is healthy, so the miss never appears in the measured sensitivity. Threshold tuning on the proxy labels can therefore report 95% sensitivity while the true rate is far lower, and lower still in subgroups whose care is documented less thoroughly.
We propose to treat "is the true sensitivity at this threshold at least 95%?" as a statistical estimation problem with a small expert-review budget. Most patients get only cheap extracted labels. A few hundred get gold chart review, and they are chosen adaptively, concentrated where hidden misses are likely. A prediction-powered estimator then combines the two sources into a valid lower confidence bound on true sensitivity at every candidate threshold. The new ingredient is to use the extraction pipeline's own intermediate outputs as signals of where the proxy is probably wrong. These include findings the extractor proposed and then pruned for weak evidence, and items recovered only by an "omission" pass. Those signals are used both to decide whom to review and to sharpen the estimate. The deliverable is a threshold-selection procedure for rare-disease screening on note-derived labels, along with an answer to whether extraction traces actually buy anything over sampling on the model score alone.
Core Claim
Sensitivity at threshold $\tau$ is a ratio of two population means. With $s(x)$ the screening score, $Y$ the true label, $\hat Y$ the extracted proxy label, and $\pi_i$ the known probability that patient $i$ was sent for gold review, a design-based prediction-powered estimate over $N$ patients and the reviewed set $R$ is
$$ \hat S(\tau)=\frac{\frac1N\sum_{i=1}^N \mathbf 1[s_i\ge\tau]\hat Y_i+\frac1N\sum_{i\in R}\mathbf 1[s_i\ge\tau]\frac{Y_i-\hat Y_i}{\pi_i}}{\frac1N\sum_{i=1}^N \hat Y_i+\frac1N\sum_{i\in R}\frac{Y_i-\hat Y_i}{\pi_i}} . $$
The correction terms are unbiased because we set $\pi_i$ ourselves, so the estimator needs no covariate-shift assumption between reviewed and unreviewed patients. The variance is driven by the residual $Y-\hat Y$ in proportion to $1/\pi$. Low-score patients whose notes contain hedged or pruned mentions are rare and carry most of the hidden false negatives. If they are sampled at the same rate as everyone else, the denominator correction is very noisy. Our claim is twofold. First, setting $\pi$ from extraction traces as well as the model score yields much tighter lower bounds on $S(\tau)$ for the same review budget. Second, this lets a hospital choose a higher (less alarm-heavy) threshold that still holds the sensitivity guarantee, overall and within insurance or demographic strata. The procedure selects $\tau^*$ as the largest grid threshold whose simultaneous lower bound clears the target.
Relation to Prior Work
The motivation comes from proxy-bias work. Obermeyer et al. (2019) showed that a cost proxy for health need encoded access disparities. Fogliato et al. (2020) and Li (2024) showed that error-rate and fairness metrics computed against a tainted label can look perfect while hiding real disparity. Those papers diagnose the problem. We do not try to fix the training labels. We fix the measurement that a rule-out threshold is chosen on.
The method draws on two semi-supervised inference papers. Towards the Efficient Inference by Incorporating Automated Computational Phenotypes under Covariate Shift builds a doubly robust estimator that combines abundant automated phenotypes with scarce chart reviews. It reports confidence intervals up to 60% shorter, with efficiency coming from phenotypes on unlabeled patients. Its estimands are regression parameters, however, and it assumes covariate shift. M-estimation under Two-Phase Multiwave Sampling with Applications to Prediction-Powered Inference chooses gold labels in waves toward high proxy-error regions and reports effective sample size gains of up to 1.8x. It does this for means and quantiles on tabular, satellite, and protein data. We reuse its multiwave inverse-probability design. The differences are that our estimand is a threshold-indexed sensitivity curve that will be searched over, our proxy comes from clinical text, and our design variables include signals from inside the extractor. Needle in a Haystack: Label-Efficient Evaluation under Extreme Class Imbalance supplies the imbalance side: adaptive importance sampling over score partitions with valid intervals and order-of-magnitude error reductions. It assumes the queried labels are correct and that the score is the only sampling signal. We keep the gold-oracle assumption for reviewed patients, but we drop the idea that the cheap labels are trustworthy, and we add non-score signals.
On extraction, Self-Verification Improves Few-Shot Clinical Information Extraction adds omission-recovery, evidence-grounding, and pruning passes. These raise MIMIC-IV ICD-10 F1 from 0.487 to 0.533. Pruning is necessary for precision, but it discards weakly evidenced findings. Label uncertainty-guided multi-stream model for disease screening found that ambiguous, high-disagreement cases are the ones that matter most for screening. Together these suggest that the pruned set is where proxy false negatives live. We use the pruned set as a sampling stratum rather than trying to tune the pruner. Combining Automatic Labelers and Expert Annotations for Accurate Radiology Report Labeling Using BERT (CheXbert) is our default extractor for radiology. It reaches average F1 0.798 against 0.743 for the rule-based labeler and 0.805 for radiologists, but it treats all error types symmetrically.
Finally, From Theory to Decision Rule: Calibrating the Noisy-Label Crossover for VLM Weak Supervision Across Three Medical-Imaging Benchmarks constrains our design. It found that noise-robust losses do not move the point at which weak labels start hurting, and that global AUC hides per-class behavior on rare classes. This is why we do not propose a better training loss, and why every result is reported per finding and per prevalence stratum.
Research Program
The work has three parts.
The first is the estimator. We compute the ratio estimate above with delta-method variance, cross-fit so that any learned residual model, which predicts $Y-\hat Y$ from score, extraction traces, and note metadata, is never fitted on the patients it corrects. We obtain simultaneous lower bounds over a threshold grid, using Bonferroni as the simple default and a monotone scan as a tighter option. This simultaneity matters because choosing $\tau^*$ after looking at the bounds is a selection step. Without it, the guarantee is invalid in exactly the way post-hoc threshold tuning is.
The second is the sampling design. Review proceeds in roughly six waves, which matches where the multiwave paper reports gains flattening out. Each wave reallocates $\pi$ to minimize the estimated variance of $\hat S$ near the current candidate $\tau^*$. Strata are formed from score bins crossed with extraction-trace flags: no mention, mention kept, mention pruned, and mention recovered only by the omission pass. We impose minimum allocations within subgroups such as insurance type, so that subgroup bounds remain finite.
The third is the extraction layer. We run the self-verification pipeline and CheXbert-style encoders and log their intermediate states rather than only their final labels. Logging is cheap. The open empirical question is whether those states carry information about $Y-\hat Y$ beyond what the score already carries.
We are explicit about scope. Chart review corrects extraction error. It cannot recover disease that was never documented. Where the gold standard itself depends on access, for example outcomes defined by follow-up visits, which Potential for Algorithmic Bias in Clinical Decision Instrument Development found in about 26% of instruments, the procedure certifies sensitivity to the documented construct only. The semi-synthetic setting below measures how large that remaining gap is.
Baselines
The naive reference point is what deployed systems do. The screening model is trained on extracted labels, and $\tau$ is lowered until sensitivity measured against those same extracted labels on a held-out split reaches the target. It uses no review budget. It is the baseline we expect to fail, and the experiments quantify by how much: the shortfall between its claimed and true sensitivity, overall and in each subgroup.
The gold-only baseline spends the same review budget on a simple random sample. It estimates sensitivity from reviewed patients alone with exact binomial bounds and picks the largest threshold whose bound clears the target. It is valid by construction, so it is the fair reference for alarm burden: any method that also holds coverage must flag fewer patients than this one to be worth using.
The strongest existing competitor is score-only adaptive sampling with prediction-powered correction. This combines the adaptive importance sampling of Needle in a Haystack with the multiwave inverse-probability design of M-estimation under Two-Phase Multiwave Sampling, with partitions defined by classifier score only, and uses the same ratio estimator and simultaneous bounds as our method. No reported result found on Lacuna for any of these methods applied to threshold certification of clinical screening sensitivity. The closest reported figures are the effective sample size gain of up to 1.8x for multiwave sampling on non-clinical tasks, the order-of-magnitude error reduction for adaptive importance sampling on amzn-goog, and confidence intervals up to 60% shorter for automated phenotypes in Towards the Efficient Inference by Incorporating Automated Computational Phenotypes under Covariate Shift. We also run the doubly robust estimator from that paper with uniform-random review as a non-adaptive semiparametric comparator.
The key ablation removes the extraction-trace strata and residual-model features from our method. Everything else is identical: score partitions, wave schedule, and estimator. This isolates the proposal's single new ingredient. All methods share the same patients, extractor outputs, review budgets (100, 250, 500, and 1,000 reviews), threshold grid, and target levels, and any learned components get the same tuning budget on separate folds. Beating the strongest competitor means two things at matched budget. First, coverage holds at or above nominal. Second, either the lower bound at the chosen threshold is meaningfully tighter, or the flag rate at a certified 95% sensitivity is lower, with the gain stable across repeated sampling draws and not confined to a single finding.
Why not just…?
Why not just tune the threshold on the extracted labels, since they are already about as good as radiologists? CheXbert's average F1 of 0.798 against 0.805 for radiologists describes errors in aggregate. Sensitivity under rule-out depends on the small set of proxy errors that coincide with low scores, and an F1 average says nothing about where those errors sit. Fogliato et al. (2020) show that evaluation against a tainted label can look correct while being wrong. The semi-synthetic experiment measures the gap between claimed and true sensitivity directly, so this baseline is tested rather than dismissed.
Why not just review a random sample and use exact binomial bounds? This baseline is valid. Its weakness is cost under imbalance. At 2% prevalence, 500 random reviews yield about ten positives, and a lower bound computed from ten positives is too loose to certify anything near 95%. The method then falls back to very low thresholds and heavy alarm loads. Our experiments report the flag rate this costs at each budget. If random review turns out to be competitive at realistic budgets for common findings, we will say so and restrict the claim to rare findings.
Why not just sample adaptively on the classifier score, as existing adaptive-evaluation methods do? This is the real threat. If the score already identifies where hidden misses are, extraction traces add nothing, and the contribution shrinks to applying Needle in a Haystack and multiwave sampling to a new estimand. The ablation decides this. Our hypothesis is that a model trained on extracted labels assigns low scores to patients whose findings were pruned, so the score alone cannot separate "truly negative" from "negative because the extractor dropped the finding." The trace flag can. If the ablation shows no gain, we will report a negative result: score-based adaptive certification is sufficient, and extractor internals are not worth logging.
Why not just use a better extractor, such as GPT-4 with self-verification, and trust its labels? A better extractor shrinks $Y-\hat Y$, and our estimator benefits automatically because its variance falls. It does not remove the need for certification. The self-verification gains in Self-Verification Improves Few-Shot Clinical Information Extraction, from 0.487 to 0.533 F1 on ICD-10 codes, still leave most errors in place. Its pruning step is designed to trade recall for precision, which pushes residual errors toward the false-negative side that screening cares about. We run every method with both CheXbert and an LLM self-verification extractor to show how extractor quality and review budget trade off.
Proposed Experiments
The first setting is semi-synthetic, on CheXpert Plus, where truth is controllable. We take CheXbert labels from the full report as the reference "truth." We build a degraded proxy by extracting from the impression section only and applying evidence pruning. We also build a second proxy whose degradation is made deliberately heavier for one insurance category, using the dataset's demographic fields. An image-based screening classifier is trained on the proxy. Because the reference truth exists for every patient, we can run 500 repeated sampling draws per budget. For each draw we measure whether the chosen threshold's true sensitivity meets the target, globally and per insurance stratum, and the flag rate at that threshold. Findings are grouped into common ones (effusion, edema) and long-tail ones (pneumothorax, fracture), so we can see whether gains concentrate where imbalance is worst. This setting also quantifies the documentation-layer limit: we vary how often the "truth" itself is suppressed in the degraded subgroup and measure what certification can and cannot recover.
The second setting is real, on MIMIC-IV discharge summaries. Proxies are extracted diagnoses and billing codes for a small number of conditions chosen to span prevalence from common to rare. Gold labels come from clinician chart review under the same budgets. Here true coverage cannot be computed. We therefore compare interval width and certified thresholds across methods, and we check estimator agreement on a held-out fully reviewed audit set of a few hundred patients drawn with known probabilities. If the UF Health diabetes cohort from the automated-phenotype paper is accessible, it serves as an independent replication with existing gold labels. The extreme-imbalance suite from Needle in a Haystack is used only as a sanity check that our implementation of the adaptive importance sampling baseline reproduces that paper's qualitative advantage over passive sampling.
Three outcomes would decide the proposal.
The first concerns the naive baseline. In the semi-synthetic setting, the naive method should show a clear gap between claimed and true sensitivity, larger in the deliberately under-documented stratum and for rare findings. If no such gap appears, the motivating problem is smaller than we believe.
The second concerns validity. Every budget-using method should hold nominal coverage. Any method that fails coverage is disqualified regardless of its flag rate.
The third is the trace ablation, which decides novelty. Score-plus-trace sampling must produce tighter bounds, or lower flag rates at certified sensitivity, than score-only adaptive sampling at matched budget. The gain should be largest on long-tail findings and the under-documented stratum. If the gain is absent, the paper reports that score-based adaptive certification suffices.
References
- Dissecting racial bias in an algorithm used to manage the health of populations
- Fairness Evaluation in Presence of Biased Noisy Labels
- Label Bias: A Pervasive and Invisibilized Problem
- Towards the Efficient Inference by Incorporating Automated Computational Phenotypes under Covariate Shift
- M-estimation under Two-Phase Multiwave Sampling with Applications to Prediction-Powered Inference
- Needle in a Haystack: Label-Efficient Evaluation under Extreme Class Imbalance
- Self-verification improves few-shot clinical information extraction
- A Label Uncertainty-Guided Multi-Stream Model for Disease Screening
- Combining Automatic Labelers and Expert Annotations for Accurate Radiology Report Labeling Using BERT
- From Theory to Decision Rule: Calibrating the Noisy-Label Crossover for VLM Weak Supervision Across Three Medical-Imaging Benchmarks
- Potential for Algorithmic Bias in Clinical Decision Instrument Development
- CheXpert Plus: Augmenting a Large Chest X-ray Dataset with Text Radiology Reports, Patient Demographics and Additional Image Formats