Build-Direction-Aware 3D Reconstruction of Laser-Melted Metal from 2D Cross-Sections

Metal parts made by selective laser melting (SLM) are built by melting thin layers of metal powder with a laser, one layer on top of the last. The finished part carries a hidden 3D defect structure: gas pores, unmelted gaps between tracks, and track boundaries, all arranged in a way that depends on the build direction and on how the laser rotates its scan pattern from one layer to the next. Measuring this structure in 3D requires X-ray computed tomography (CT), which is slow and expensive. Polished 2D cross-sections are cheap. This proposal asks whether a generative model trained only on a few 2D cuts, taken at chosen angles, can produce statistically faithful 3D defect volumes, and which cuts a lab should make to get there.

The nearest existing method, MicroLad, builds 3D microstructures by denoising the three axis-aligned planes of a volume together, and its authors state that it does not enforce consistency along diagonal directions. For SLM this is the central problem rather than a detail. Rotating the scan pattern between layers creates spatial correlations along directions that lie in no coordinate plane, so axis-aligned sections cannot constrain them. We propose a single 2D denoiser that is told the angle of the cut relative to the build direction and the laser settings. It is trained on cuts at a few angles and used to guide a 3D volume through score distillation on planes at all observed orientations and positions. A simple rule then picks the next physical cut from the disagreement among generated volumes.

Core Claim

For anisotropic, build-direction-dependent materials such as as-built SLM metal, two things are true. Reconstruction from axis-aligned sections alone is ambiguous. A small number of oblique cuts, used through an angle-conditioned 2D prior, resolves most of that ambiguity. The new content has three parts. The first is treating the build direction as a privileged frame, which neither computer-vision lifting methods nor MicroLad do. The second is enforcing consistency on oblique planes. The third is turning the choice of which cut to make next into a measurable, active decision.

The claim is falsifiable in a strong form. If MicroLad with extra fixed diagonal planes matches the angle-conditioned model, or if orthogonal-only reconstruction already recovers correlations along the body diagonals, the claim fails.

Positioning Against Prior Work

The method builds directly on two lines of work that lift 2D generative models into 3D.

Score Jacobian Chaining does two things we reuse. It pushes gradients from a pretrained 2D diffusion model back through a differentiable renderer into a voxel field. It also adds noise to clean renders before scoring them, which fixes the mismatch between clean renders and the noisy images the model expects. Our slicing operator plays the role of that renderer. The difference is that we constrain the interior volume, while that work constrains only exterior appearance.

MVDream removes inconsistent views by conditioning a diffusion model on camera parameters. Our angle-of-cut embedding is the volumetric analogue of that camera embedding.

MicroLad is the closest work and it both motivates and limits the proposal. It shows three things: latent multi-plane denoising plus score distillation reconstructs 3D stochastic microstructures from 2D images; it generates a 64³ volume in under 10 seconds; and its two-point correlation error stays below 1%. Its orthogonal-plane design and its stated diagonal gap are exactly what we attack. It also targets rocks, electrodes and separators rather than as-built metal.

A second group of papers supplies SLM context and one warning. Ogoke et al.'s melt pool diffusion model shows that conditional diffusion captures stochastic keyhole oscillation where deterministic networks fail (Pearson R² 0.74 versus 0.06). It does so in 2D single-track slices. It motivates conditioning on laser power and speed, and it warns against deterministic regression for defect statistics.

The SLM lattice studies show that the targets of interest are real, printed, performance-critical parts:

  • Deng et al. report porous FeMnCoCr gyroids with 197 MPa yield strength.
  • Li et al. study Ti6Al4V/AlSi12 interpenetrating composites.

Neither reconstructs as-built 3D defect structure.

Finally, the generative topology-design papers are not competitors, because they generate designed geometry rather than as-built defects. These include TopoDiff, OAT and UniMate. We note them to rule out one tempting design. Cross-sections of 3D optimal structures do not resemble 2D optimal structures, so a pretrained 2D topology prior is the wrong prior to lift.

Research Program

The 3D volume $V$ is a latent grid decoded to a pore/metal/track-boundary field, following MicroLad's latent compression. A plane is described by a unit normal $n$ and an offset. The slice operator $S_n(V)$ resamples the volume on that plane, aligned so that the in-plane "up" axis points as close to the build direction as possible.

The 2D denoiser $\epsilon_\theta(x_t, t, \phi, c)$ is trained on micrographs at noise level $t$. It is conditioned on two things: the angle $\phi$ between the cut plane and the build direction, and the laser settings $c$ (power, speed, scan-rotation schedule). Generation updates $V$ with the score-distillation gradient averaged over planes whose angles are in the observed set $\Phi_{\text{obs}}$:

$$\nabla_V \mathcal{L} = \mathbb{E}_{n:\,\phi(n)\in\Phi_{\text{obs}},\; t,\; \epsilon}\Big[w(t)\,\big(\epsilon_\theta(S_n(V)_t, t, \phi(n), c) - \epsilon\big)\,\frac{\partial S_n(V)}{\partial V}\Big]$$

Here $S_n(V)_t$ is the noised slice, $\epsilon$ is the added noise, and $w(t)$ is the usual timestep weighting. The expectation also runs over the azimuth of the plane around the build axis. This matters for SLM, because a cut at a fixed tilt still sees different scan tracks as it rotates. MicroLad's fixed triple of planes cannot express this.

We will also test a second regime in which planes at unobserved angles are scored by the model's interpolation in $\phi$. Whether that interpolation helps or hurts is a result, not an assumption.

The active-cutting loop works as follows. We generate an ensemble of volumes from the current data, compute slice statistics (two-point correlation, pore aspect-ratio histograms) along each candidate cut angle, and recommend the angle where the ensemble disagrees most. The output is a sequence of cuts ranked by how much they reduce 3D uncertainty, which a metallography lab can act on directly.

Baselines

Naive reference: independent slices. This treats the part as isotropic. A single 2D denoiser is trained on layer-plane (XY) images, and 3D is built by the same orthogonal-plane procedure using that one model for all three axes. It shows what ignoring the build direction costs.

Strongest existing method: MicroLad's orthogonal multi-plane denoising. This is MicroLad with separate or shared models on XY, XZ and YZ cuts. On its own benchmark it reports two-point correlation relative error below 1% and 64³ generation in under 10 seconds. That error is measured along the directions it constrains, and no reported result was found on Lacuna for its accuracy along oblique directions.

We will run it on identical training images, the same latent autoencoder, the same volume resolution and the same GPU-hour budget, with its hyperparameters tuned on the same validation split as ours. Beating it means lower correlation error along off-axis directions, especially body diagonals, with no worse error along the axes.

Key ablation: MicroLad plus fixed diagonal planes. This adds a fixed set of 45° planes, each with its own model, but has no continuous angle conditioning and no azimuth sampling. If it matches our model, the continuous orientation embedding is unnecessary, and we will say so.

Data-rich reference: direct 3D model on CT. A 3D latent diffusion model is trained directly on the few available CT volumes, under the same compute. It asks whether a handful of CT scans beats many 2D cuts.

Classical reference: statistical reconstruction. This is correlation-matching reconstruction by simulated annealing, a standard approach that no paper in our file covers. It is run to the same target statistics. No reported result was found on Lacuna for it on SLM material.

Why not just…?

Why not just add a few diagonal planes to MicroLad? This is the most serious threat, and it is a named ablation above. It can fail for two reasons. Fixed 45° planes still miss correlations at other tilts. More importantly, the scan-rotation pattern makes a cut's appearance depend on its azimuth around the build axis, which a fixed plane set samples at only one or two values. The synthetic experiment with a known ground truth settles this directly. If fixed diagonals recover the directional correlation map as well as azimuth-sampled, angle-conditioned planes, we drop the continuous conditioning.

Why not just CT-scan the coupons? CT is the ground truth we evaluate against, and we will use it. It does not scale to the many laser settings and build orientations a process-development campaign needs. The comparison against the direct 3D model on CT measures how many CT volumes our 2D-cut approach is worth. If three CT scans beat twenty cuts, the proposal's practical value collapses. We report that tradeoff rather than assume it.

Why not just simulate the defects? High-fidelity melt-pool simulation takes hours of computation per millisecond of process time, as noted in the melt pool diffusion work. Even the surrogate there covers only 2D single tracks, not multi-layer, multi-track porosity. Simulation is not a practical source of part-scale 3D training volumes today. It could, however, supply conditioning, and we treat that as future work.

Why not just use a classical statistical reconstruction? Correlation-matching reconstruction is fast to set up and is a fair baseline. Its outputs are only as good as the statistics fed to it. Given only orthogonal-section statistics, it is equally blind to body-diagonal correlations. The decisive synthetic pairs below test exactly this.

Proposed Experiments

Synthetic study with known ground truth (first, cheap and decisive). We procedurally generate 3D anisotropic volumes that mimic SLM. They contain elongated lack-of-fusion voids lying in the layer plane, spherical keyhole-like pores, and track boundaries whose orientation rotates by a fixed angle from layer to layer.

We also construct pairs of volumes whose axis-aligned section statistics are matched but whose correlations along body-diagonal directions differ. This is possible because vectors off every coordinate plane are unconstrained by those sections.

Each method sees 2D cuts only. The primary metric is the directional two-point correlation error integrated over the sphere of directions, reported separately for on-axis and off-axis directions. Secondary metrics are pore aspect-ratio and orientation distributions and pore connectivity.

The decisive check has a clear pass condition. Orthogonal-only methods should fail to separate the matched pairs; ours, given one or two oblique cuts, should separate them. If ours also fails, the core claim is wrong.

Method transfer on MicroLad's benchmark. On the anisotropic battery separator case from the MicroLad benchmark, we compare two things against MicroLad's orthogonal reconstruction. First, off-axis correlation error. Second, effective diffusivity computed with the same differentiable solver used in MicroLad. This confirms the gain is not an artifact of our synthetic generator.

Printed Ti6Al4V coupons. We will print cubes across a grid of laser power and speed and two scan-rotation schedules. A subset gets CT scans, which serve as held-out evaluation only. Each cube is sectioned at a small set of angles relative to the build direction.

We measure four things: directional correlation error against CT, pore-size and sphericity distributions, and a downstream quantity. That downstream quantity is effective stiffness or permeability from finite-element or flow solvers run on the reconstructed volume and on CT, comparing the two.

The active-cutting rule is evaluated by the error curve versus number of cuts. It is compared with cutting at uniformly spaced angles and with the standard metallographic practice of cutting only the layer plane and one vertical plane. The rule is worthwhile if it reaches a given CT-matching error with fewer physical cuts than uniform spacing.

Finally, we test generalization across laser settings. We hold out a power/speed setting entirely and check whether conditioning on $c$ produces volumes whose pore statistics match CT at that unseen setting.