PCam

11 papers · 25 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

0.80.90.91.0202020232026LoTeNet: 0.943 (2020)Student Head I: 0.9216 (2022)BiomedCLIP structured weak labels, DenseNet-121: 0.844 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 25 of 25 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026BiomedCLIP structured weak labels, DenseNet-121 proposedAUC.844seeds=3 · backbone=DenseNet-121 · gold_count=10 · weak_labels=50KFrom Theory to Decision Rule: Calibrating the Noisy-Label Crossover for VLM Weak Supervision Across Three Medical-Imaging Benchmarks
Source quote
L222: .844
2026Matched-rate random noise, DenseNet-121 baselineAUC.946seeds=3 · backbone=DenseNet-121 · gold_count=10 · noise_type=matched-rate random · weak_labels=50KFrom Theory to Decision Rule: Calibrating the Noisy-Label Crossover for VLM Weak Supervision Across Three Medical-Imaging Benchmarks
Source quote
L223: .946
2025CLIP-IT (ViT-B/8) proposedaccuracy gain+4.4%backbone=CLIPCLIP-IT: CLIP-based Pairing for Histology Images Classification
Source quote
L95: \autoref{tab:perf} presents the average classification accuracy and standard deviation (std) across several state-of-the-art vision backbones, trained either as a unimodal baseline, or with the proposed \texttt{CLIP-IT}\xspace method. Evaluation is performed on three histopathology datasets: PCAM, BACH, and CRC. \texttt{CLIP-IT}\xspace improves the unimodal baselines in most settings and maintains performance in a few other settings. For example, on PCAM, \texttt{CLIP-IT}\xspace yields gains as high as +4.4% for ViT-B/8. On BACH, performance improvements are most notable for models like UNI and ViT-S/16, with gains up to +2.9%. The variance in BACH stems from the base vision model's instability on this small dataset. Our method consistently improves or matches performance despite this variance, showing robustness to backbone fluctuations. Although CRC has strong unimodal baselines (e.g., ViT-B/16 with 95.9%), \texttt{CLIP-IT}\xspace still offers modest improvements or preserves parity in most cases. No unimodal backbone experiences significant performance degradation when enhanced with \texttt{CLIP-IT}\xspace. These results have a combined p-value of 2.65×10 (-5), indicating a highly significant overall effect.
2025FTCFormer proposedclassification accuracy87.49resolution=64×64FTCFormer: Fuzzy Token Clustering Transformer for Image Classification
Source quote
L229: FTCFormer │ 87.49
2025TCFormer baselineclassification accuracy86.47resolution=64×64FTCFormer: Fuzzy Token Clustering Transformer for Image Classification
Source quote
L228: TCFormer \cite{tcformer} │ 86.47
2024GUD real-space column-wise schedule (b=0.3) proposednegative log-likelihood (NLL)3.90 bits/dimschedule=real-space column-wise, b=0.3 · resolution=32×32GUD: Generation with Unified Diffusion
Source quote
L352: We trained separate score networks at b=0.3 and b=0.5 on the PCAM dataset \citep{Veeling2018-qh}, downscaled to 32 × 32 pixels, obtaining negative log-likelihoods of 3.90 and 3.94\,bits/dim, respectively.
2024GUD real-space column-wise schedule (b=0.5) proposednegative log-likelihood (NLL)3.94 bits/dimschedule=real-space column-wise, b=0.5 · resolution=32×32GUD: Generation with Unified Diffusion
Source quote
L352: We trained separate score networks at b=0.3 and b=0.5 on the PCAM dataset \citep{Veeling2018-qh}, downscaled to 32 × 32 pixels, obtaining negative log-likelihoods of 3.90 and 3.94\,bits/dim, respectively.
2024CAMP-Phikon proposedF10.985split: test · backbone=Phikon · evaluation-level=patchCAMP: Continuous and Adaptive Learning Model in Pathology
Source quote
L331: Overall, CAMP was able to conduct the 11 different classification tasks in an accurate and consistent manner (Fig. \ref{fig_camp_vs_full_ft}), achieving 0.756\sim0.861 F1, 0.809 F1, 0.488\sim0.905 F1, 0.478\sim0.998 F1, 0.961 F1, 0.915 F1, 0.895 F1, 0.782 F1, 0.985 F1, 0.486 F1, and 0.838 F1 for colorectal cancer grading (Colon-1 and Colon-2), gastric cancer grading, prostate cancer grading (UHU, UBC, AGGC, and PANDA), colorectal tissue sub-typing (K19, K16, and HunCRC-P), liver cancer grading, kidney cancer grading, bladder cancer grading, breast cancer sub-typing, breast metastasis detection, colorectal polyp sub-typing and lung cancer detection, respectively.
2024CWT-Net proposedAcc80.85backbone=ResNet-50 · sr-scale=2×CWT-Net: Super-resolution of Histopathology Images Using a Cross-scale Wavelet-based Transformer
Source quote
L344: CWT-Net │ 88.12 │ 80.85
2024SWD-Net baselineAcc80.48backbone=ResNet-50 · sr-scale=2×CWT-Net: Super-resolution of Histopathology Images Using a Cross-scale Wavelet-based Transformer
Source quote
L343: SWD-Net\cite{bib27} │ 86.47 │ 80.48
2024DenseNet121 baselineRecall drop0.40context-manipulation=black borderDoes context matter in digital pathology?
Source quote
L106: It is observed that the metric that is the most affected by limiting the amount of contextual information available at the prediction time is recall. This metric is especially important in healthcare where false negatives are of the greatest concern. The biggest drop in recall (0.84) occurs in the case of MoCo\xspace model which starts to predict mostly one class - normal. At the~same time, in the case of this model, the precision curve slightly increases with the decrease of context size (up to 0.016 when context\_size=0) even though the reference value was already very high (0.9617). The two models that experience the~smallest drop of recall are Swin\xspace (0.41) and \DenseNet121 (0.40).
2024DenseNet121 baselinePrecision drop0.14context-manipulation=black borderDoes context matter in digital pathology?
Source quote
L108: Note that precision seems to be the least impacted metric by the limitation of contextual information. The~most considerable decrease is observed in the~case of \DenseNet121 (0.14) and MAE\xspace (0.11), however, in the~first case, the~significant drop is observed even when the~amount of context is only slightly limited.
2024Swin baselinePercentage of images with the same prediction regardless of context size72.41%Evaluated across different context sizes.Does context matter in digital pathology?
Source quote
L123: 54.66 │ 52.39 │ 72.41 │ 69.06 │ 60.76 │ 58.20
2024DenseNet121 baselinePercentage of images with the same prediction regardless of context size52.39%Evaluated across different context sizes.Does context matter in digital pathology?
Source quote
L123: 54.66 │ 52.39 │ 72.41 │ 69.06 │ 60.76 │ 58.20
2023Linear probing baselinetest accuracy83.5%split: test · linear-probe · params=2B · backbone=ViT-B/32 · pretraining=OpenCLIP LAION-2BOn the Benefits of Public Representations for Private Transfer Learning under Distribution Shift
Source quote
L260: Linear probing │ 83.5 │ 42.1 │ 91.7
2020Student Head I proposedAUC0.9216split: test · model=Student Head IToward Scalable and Unified Example-Based Explanation and Outlier Detection
Source quote
L369: Student Head I \ │ 83.3 │ 0.9216
2020LoTeNet proposedAUC0.943split: test · layers=3 · kernel-size=2 · bond-dimension=5Tensor Networks for Medical Image Classification
Source quote
L141: {LoTeNet (ours)} │ 0.8 │ 0.943
2020LoTeNet proposedGPU memory utilization0.8 GBsplit: test · layers=3 · kernel-size=2 · bond-dimension=5Tensor Networks for Medical Image Classification
Source quote
L141: {LoTeNet (ours)} │ 0.8 │ 0.943
2020Teacher (baseline) baselineAUC0.9142split: test · model=TeacherToward Scalable and Unified Example-Based Explanation and Outlier Detection
Source quote
L368: \ Teacher (baseline) \ │ 80.5 │ 0.9142 \hhline{|=|=|=|}
2020Rotation Eq-CNN baselineAUC0.963split: testTensor Networks for Medical Image Classification
Source quote
L139: Rotation Eq-CNN │ 11.0 │ 0.963
2020DenseNet baselineAUC0.962split: test · layers=4 · growth-rate=12Tensor Networks for Medical Image Classification
Source quote
L140: {DenseNet} │ 10.5 │ 0.962
2020Tensor Net-X (β=10) baselineAUC0.908split: test · architecture=single-layer MPS · bond-dimension=10Tensor Networks for Medical Image Classification
Source quote
L142: {Tensor Net-X (\beta=10)} │ 5.2 │ 0.908
2020DenseNet baselineGPU memory utilization10.5 GBsplit: test · layers=4 · growth-rate=12Tensor Networks for Medical Image Classification
Source quote
L140: {DenseNet} │ 10.5 │ 0.962
2019CELNet proposedAcc91.87split: testEvidence Localization for Pathology Images Using Weakly Supervised Learning
Source quote
L100: CELNet │ 91.87 │ 97.72 │ 297K
2019P4M-DenseNet baselineAcc89.80split: testEvidence Localization for Pathology Images Using Weakly Supervised Learning
Source quote
L99: P4M-DenseNet │ 89.80 │ 96.30 │ 119K